Position: Home > > Environmental monitoring and analysis > Gas on-line monitoring > Flue gas monitoring system > TR-9300 Continuous Emission Monitoring System (CEMS)

TR-9300 Continuous Emission Monitoring System (CEMS)

Product ID:HQZXyanqi028

Price: US$28,680.00 ~ US$35,860.00 PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberTR - 9300
    Brand NameYM
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    TR-9300 Continuous Emission Monitoring System (CEMS)
    Product Overview
    The TR-9300 Continuous Emission Monitoring System (CEMS) is an advanced industrial flue gas monitoring solution developed by integrating global online gas analysis technologies with China’s environmental monitoring standards. Built on extensive industrial process experience, the system provides accurate, real-time monitoring of gaseous and particulate pollutants in emission sources.
    The TR-9300 is widely used for continuous monitoring of SO, NOx, CO, CO, O, particulate matter (dust), temperature, pressure, humidity, and gas flow rate. It features integrated data acquisition and processing functions, capable of generating real-time charts, environmental compliance reports, and remote data transmission to environmental protection authorities.
    Designed for industrial-grade reliability, the TR-9300 CEMS is suitable for power plants, chemical industries, cement plants, metallurgy, and other high-emission industrial environments.

     
    Key Features
        •Continuous real-time flue gas emission monitoring system
        •Simultaneous measurement of multiple pollutants and parameters
        •Monitors SO, NOx, CO, CO, O, dust, temperature, pressure, humidity, and flow
        •Industrial-grade design with proven field applications
        •High stability and long-term continuous operation
        •Integrated data acquisition and processing system
        •Automatic generation of emission reports and trend graphs
        •Remote data transmission to environmental regulatory platforms
        •Modular system design for flexible configuration
        •Strong anti-interference capability for harsh environments
        •Supports environmental compliance and regulatory reporting
     
    Working Principle
    The TR-9300 CEMS collects flue gas samples directly from industrial emission sources such as stacks or chimneys. The sampled gas is transported through a conditioning system where temperature, humidity, and particulate conditions are stabilized.
    Gas analyzers based on optical, electrochemical, or infrared technologies measure key gaseous pollutants including SO, NOx, CO, CO, and O. Simultaneously, particulate concentration (dust), temperature, pressure, humidity, and flow velocity are measured using dedicated sensors.
    All collected data is processed by a central data acquisition and control unit, which performs signal calibration, compensation, storage, and analysis. The system then generates real-time monitoring curves, statistical reports, and compliance documentation, which can be transmitted to environmental monitoring agencies via network communication.

     
    Technical Specifications
    Parameter Measurement Range
    SO 0–5000 ppm (Selectable)
    NOx 0–5000 ppm (Selectable)
    CO 0–5000 ppm (Selectable)
    O 0–10% / 0–25%
    Dust (Particulate Matter) 0–100% opacity / 0–4000 mg/m³
    Temperature 0–300°C
    Flow Velocity 0–40 m/s
    Humidity 0–20%
    Pressure 0–130 KPa
     
    System Functions
    Function Description
    Data Acquisition Real-time multi-parameter signal collection
    Data Processing Automatic calibration and compensation
    Report Generation Environmental compliance reports
    Data Visualization Real-time trend charts and graphs
    Remote Transmission Upload to environmental authorities
    Alarm Function Threshold-based emission alerts
     
    Typical Applications
    Power Generation Industry

        •Thermal power plant emission monitoring
        •Boiler flue gas analysis
        •Combustion efficiency optimization
    Cement Industry
        •Kiln exhaust gas monitoring
        •Dust emission control
        •NOx/SO reduction tracking
    Chemical Industry
        •Process emission monitoring
        •Hazardous gas control
        •Regulatory compliance reporting
    Metallurgy Industry
        •Furnace emission control
        •Smelting process gas monitoring
        •Energy efficiency optimization
    Waste Incineration
        •Incinerator gas emission tracking
        •Dioxin-related process control support
        •Environmental compliance monitoring
    Environmental Protection Agencies
        •Continuous industrial emission supervision
        •Regulatory enforcement and reporting systems
        •Air pollution data collection networks
     
    TR-9300 vs Conventional Emission Monitoring Systems
    Feature TR-9300 CEMS Conventional Monitoring System
    Multi-Gas Monitoring SO, NOx, CO, CO, O Limited gases
    Particulate Monitoring Yes (Dust/Opacity) Optional or absent
    Environmental Parameters Temperature, Pressure, Humidity, Flow Partial
    Data Processing System Advanced integrated system Basic
    Remote Reporting Supported Limited
    Compliance Reporting Automatic generation Manual
    Industrial Adaptability High Moderate
    Stability in Harsh Environments Excellent Variable
    System Integration SCADA / Regulatory Platforms Limited
     
    FAQ
    1. What gases can the TR-9300 monitor?
    The system monitors SO, NOx, CO, CO, and O, along with particulate matter, temperature, pressure, humidity, and flow rate.
    2. Is the system suitable for environmental compliance reporting?
    Yes. The TR-9300 is designed for continuous emission monitoring and can automatically generate reports for submission to environmental authorities.
    3. Can the system transmit data remotely?
    Yes. It supports remote data transmission to environmental protection agencies and central monitoring platforms.
    4. What industries commonly use CEMS systems?
    It is widely used in power plants, cement production, chemical processing, metallurgy, waste incineration, and industrial boiler systems.
    5. Does the system measure dust concentration?
    Yes. It supports dust measurement in opacity (%) and concentration (mg/m³) formats.
    6. Is the system suitable for harsh industrial environments?
    Yes. The TR-9300 is designed with industrial-grade components for stable operation in high-temperature, high-dust, and corrosive environments.
    7. Can it integrate with existing control systems?
    Yes. The system can integrate with SCADA, DCS, and environmental monitoring platforms.

     
    Why Choose TR-9300 CEMS?
    The TR-9300 Continuous Emission Monitoring System delivers a complete solution for industrial flue gas monitoring, combining multi-gas analysis, particulate detection, environmental parameter measurement, and advanced data processing into a single integrated platform. With strong regulatory compliance capability, real-time monitoring, and remote reporting functions, it is a reliable choice for modern environmental management and industrial emission control systems.
     
     


  • FAQ
    1. What gases can the TR-9300 monitor?
    The system monitors SO₂, NOx, CO, CO₂, and O₂, along with particulate matter, temperature, pressure, humidity, and flow rate.
    2. Is the system suitable for environmental compliance reporting?
    Yes. The TR-9300 is designed for continuous emission monitoring and can automatically generate reports for submission to environmental authorities.
    3. Can the system transmit data remotely?
    Yes. It supports remote data transmission to environmental protection agencies and central monitoring platforms.
    4. What industries commonly use CEMS systems?
    It is widely used in power plants, cement production, chemical processing, metallurgy, waste incineration, and industrial boiler systems.
    5. Does the system measure dust concentration?
    Yes. It supports dust measurement in opacity (%) and concentration (mg/m³) formats.
    6. Is the system suitable for harsh industrial environments?
    Yes. The TR-9300 is designed with industrial-grade components for stable operation in high-temperature, high-dust, and corrosive environments.
    7. Can it integrate with existing control systems?
    Yes. The system can integrate with SCADA, DCS, and environmental monitoring platforms.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com