YSM-8103-03 Area Array Backlit Spectrometer Introduction: The YSM-8103 series spectrometer is developed based on the Hamamatsu array backlit uncooled CCD sensor, providing two versions: ultraviolet sensitive and infrared sensitive. It is the cost-effective choice for weak spectral measurement. Its wavelength range and optical resolution can be independently configured, supporting secondary development, trigger control, and deep customization of the spectrometer according to your needs. YSM-8103-03 series spectrometer, equipped with Hamamatsu S16010 2048 × 64 pixel planar array CCD enhances sensitivity in the range of 700-1100nm, making it suitable for weak light measurements such as fluorescence spectroscopy and Raman spectroscopy. The YSM-8103-04 series spectrometer is equipped with a Hamamatsu S10420 2048x64 pixel array CCD, which improves sensitivity in the range of 200-500nm and is suitable for weak light measurement such as water quality detection, gas monitoring, and fluorescence spectroscopy. Features: 1. Area array backlit CCD, improving signal-to-noise ratio and dynamic range 2. Small size, light weight, and easy system integration 3. Linear gradient filter or long wave pass filter to eliminate secondary and advanced diffraction 4. Replaceable slit design, balancing sensitivity and resolution measurement requirements 5. Multiple communication methods such as USB2.0, RS232/485, etc 6. USB 2.0 for data transmission and power supply 7. Intelligent analysis software that reads the center wavelength and half width in real-time 8. Provide SDK secondary development package Technical parameters: Size: 165mm x 110mm x 38mm Weight: 0.7 Kg Detector: Hamamatsu S16010 array CCD: 2048 × 64 pixels, pixel size: 14 µ m × 14 µ m; Wavelength response: 200-1100nm A/D: 16bit Fiber optic connector: SMA905 Signal to noise ratio: 800:1 (full spectrum) Dynamic range: 50000:1 Integration time: 1ms-65s Communication interface: USB2.0 (12Mbps); RS232 (115200bps) Power consumption: 5 VDC, 250mA Power supply method: USB Spectral range: determined by specific grating Resolution: optimal~0.35nm (determined by both grating and slit) Trigger method: software trigger, hardware trigger, synchronous trigger Operating system: Win XP, Win7, Win8, Win10, Win11 Fiber optic connector: SMA905 (other connectors can be customized) Fixed hole positions on the shell: 5 M3 at the bottom × 4 threaded holes, 2 M3 on the side × 4 threaded holes Working temperature (recommended temperature): 5 ℃ -35 ℃ (recommended temperature 25 ℃)
Introduction: The YSM-8103 series spectrometer is developed based on the Hamamatsu array backlit uncooled CCD sensor, providing two versions: ultraviolet sensitive and infrared sensitive. It is the cost-effective choice for weak spectral measurement. Its wavelength range and optical resolution can be independently configured, supporting secondary development, trigger control, and deep customization of the spectrometer according to your needs. YSM-8103-03 series spectrometer, equipped with Hamamatsu S16010 2048 × 64 pixel planar array CCD enhances sensitivity in the range of 700-1100nm, making it suitable for weak light measurements such as fluorescence spectroscopy and Raman spectroscopy. The YSM-8103-04 series spectrometer is equipped with a Hamamatsu S10420 2048x64 pixel array CCD, which improves sensitivity in the range of 200-500nm and is suitable for weak light measurement such as water quality detection, gas monitoring, and fluorescence spectroscopy.