    Product Overview
    The XGPQ-300C Power Quality Analyzer and Recorder is a portable, multifunctional and intelligent three-phase power quality measurement instrument designed for on-site electrical testing and power quality monitoring. It features a large 5.6-inch color LCD, high-resolution display, bilingual Chinese/English interface, rugged anti-vibration housing and user-friendly operation.
    The analyzer provides 4 voltage channels and 4 current channels, allowing simultaneous measurement of three-phase voltage/current and neutral-line parameters. It can measure voltage and current RMS values, peak values, maximum/minimum values, three-phase unbalance, short-term voltage flicker, transformer K-factor, active power, reactive power, apparent power, power factor, displacement power factor, active energy, reactive energy, apparent energy, harmonics and total harmonic distortion (THD).
    The XGPQ-300C also provides real-time waveform display, phasor diagrams, harmonic bar charts, transient capture, inrush current monitoring, trend recording, alarm monitoring, screen capture and USB communication functions. It is suitable for power quality diagnosis, electrical equipment commissioning, power system maintenance, harmonic analysis, load monitoring and long-term power quality recording.

     

    Key Features
    • 4 voltage and 4 current channels for simultaneous three-phase and neutral-line measurement.
    • Real-time display of 4 voltage waveforms and 4 current waveforms.
    • Measures true RMS voltage and current, DC components, peak values and half-cycle RMS maximum/minimum values.
    • Supports phasor diagram display for analyzing phase relationships and three-phase systems.
    • Measures harmonics up to the 50th harmonic for each phase.
    • Displays voltage and current harmonic content using intuitive harmonic bar charts.
    • Measures Total Harmonic Distortion (THD) for each phase.
    • Measures active power, reactive power and apparent power for individual phases and total system values.
    • Measures active energy, reactive energy and apparent energy.
    • Provides transformer K-factor measurement for evaluating transformer harmonic loading.
    • Measures Power Factor (PF) and Displacement Power Factor (DPF/COSφ).
    • Measures short-term voltage flicker and three-phase voltage/current unbalance.
    • Dynamic transient capture detects voltage/current fluctuations, swells, sags, short interruptions, transient overvoltage, inrush current and instantaneous waveform distortion.
    • Stores up to 150 groups of transient waveforms.
    • Dedicated inrush current monitoring mode records startup current for electrical equipment.
    • Inrush current mode can record approximately 100 seconds of startup data after triggering.
    • Long-term trend recording supports 123 measurement parameters, including voltage/current parameters, power, power factor, frequency, K-factor and up to 50th-order harmonics.
    • Up to 20 parameters can be selected for simultaneous recording at 5-second intervals, allowing approximately 300 days of recording.
    • Configurable alarm monitoring supports up to 40 alarm parameter groups.
    • Up to 12,800 alarm logs can be stored.
    • Screen capture function stores measurement screens such as waveforms, harmonic bar charts and phasor diagrams.
    • Up to 60 screenshots can be stored.
    • USB communication allows measurement data, transient waveforms, trend records, alarm logs and screenshots to be transferred to a computer.
    • Chinese and English operation menus are available.
    • Built-in help menu provides on-screen operating instructions.
    • Rechargeable lithium battery provides approximately 8 hours of continuous operation.
    • Double-insulated structure with an insulated anti-vibration protective cover provides enhanced durability for field applications.

     

    Measurement and Analysis Functions
    Basic Power Quality Measurement
    The XGPQ-300C measures a comprehensive range of electrical parameters, including:
    • Voltage and current true RMS values
    • Voltage DC components
    • Voltage and current peak values
    • Maximum/minimum half-cycle RMS values
    • Frequency
    • Active power (W)
    • Reactive power (Var)
    • Apparent power (VA)
    • Power factor (PF)
    • Displacement power factor (DPF/COSφ)
    • TANφ
    • Active energy (Wh)
    • Reactive energy (Varh)
    • Apparent energy (VAh)
    • Transformer K-factor
    • Voltage and current harmonics
    • Total harmonic distortion (THD)
    • Short-term voltage flicker
    • Three-phase voltage and current unbalance

     

    Transient Capture Function
    The transient capture function dynamically detects instantaneous changes in voltage and current parameters.
    It can capture:
    • Voltage and current fluctuations
    • Voltage swells
    • Voltage sags
    • Short interruptions
    • Transient overvoltage
    • Inrush current
    • Instantaneous voltage and current waveform distortion
    The instrument can store up to 150 groups of transient waveforms, providing detailed information for diagnosing short-duration disturbances in electrical systems.

     

    Inrush Current Monitoring
    The dedicated inrush current monitoring function is designed to measure the surge current generated when electrical equipment starts.
    The analyzer can display:
    • RMS rise/fall curves during equipment startup
    • Inrush current envelope curves
    • 4-channel current waveforms
    • 4-channel voltage waveforms
    After triggering, approximately 100 seconds of startup data can be recorded, including instantaneous voltage and current values for each cycle.
    This function is useful for evaluating equipment startup characteristics and helping determine appropriate electrical system and installation capacity.

     

    Trend Recording and Data Storage
    The XGPQ-300C can continuously record a wide range of power quality parameters and generate trend graphs for long-term monitoring.
    The recordable parameters include:
    • Voltage RMS and harmonic parameters
    • Current RMS and harmonic parameters
    • Frequency
    • Voltage and current unbalance
    • Short-term voltage flicker
    • Transformer K-factor
    • Active, reactive and apparent power
    • Power factor
    • Displacement power factor
    • TANφ
    • Voltage harmonics up to the 50th order
    • Current harmonics up to the 50th order
    A total of 123 parameters are available for trend recording. Up to 20 parameters can be recorded simultaneously at 5-second intervals, with a recording capacity of approximately 300 days.

     

    Alarm Monitoring Function
    The analyzer allows users to define alarm thresholds for selected power quality parameters.
    When a measured parameter exceeds its preset limit, the instrument automatically generates an alarm log.
    Alarm monitoring can be configured for parameters such as:
    • Overvoltage
    • Overcurrent
    • Voltage/current unbalance
    • Individual harmonic limits
    • Frequency
    • Active power
    • Total harmonic distortion
    Up to 40 different alarm monitoring groups can be configured, with each group supporting different parameters and threshold values. Up to 12,800 alarm logs can be stored.

     

    Technical Specifications
    Parameter Specification
    Power Supply Rechargeable lithium battery pack, 9.6V; external charger
    Battery Indicator 5-level battery icon; low-battery warning; automatic shutdown after approximately 1 minute when battery is critically low
    Operating Current Approx. 490mA
    Continuous Operating Time Approx. 8 hours with fully charged battery
    Display 5.6-inch color LCD, 640 × 480 dots
    Display Area 116mm × 88mm
    Voltage Channels 4
    Current Channels 4
    Line Voltage 1.0V–2000V
    Phase Voltage 1.0V–1000V
    Frequency 40Hz–70Hz
    Power Parameters W, VA, Var, PF, DPF, cosφ, tanφ
    Energy Parameters Wh, Varh, VAh
    Harmonic Measurement 0–50th harmonic
    Total Harmonic Distortion Available, 0–50th harmonic, each phase
    Transient Recording 150 groups
    Voltage Flicker Available
    Inrush Current Mode Available, 100 seconds
    Three-Phase Unbalance Available
    Trend Recording Approx. 300 days when 20 parameters are recorded simultaneously at 5-second intervals
    Maximum/Minimum Recording Available
    Alarm Monitoring 40 configurable parameter types; up to 12,800 alarm logs
    Peak Measurement Available
    Screen Capture Up to 60 screenshots
    Menu Language Chinese / English
    Communication Interface USB
    Automatic Power-Off Disabled during alarm, trend recording and transient capture modes; in other modes, automatically powers off after 15 minutes without key operation following a 1-minute warning
    Backlight Available
    Instrument Dimensions 240mm × 170mm × 68mm
    Main Unit Weight 1.6kg including battery
    Input Impedance 1MΩ
    Voltage Test Lead Length 3m
    Current Clamp Cable Length 2m
    Operating Temperature/Humidity -10°C to 40°C; ≤80% RH
    Storage Temperature/Humidity -10°C to 60°C; ≤70% RH
    Dielectric Strength 3700V AC, 50Hz for 1 minute between instrument circuitry and housing
    Insulation Resistance ≥10MΩ between instrument circuitry and protective housing
    Construction Double insulation with insulated anti-vibration protective cover
    Safety Standards IEC 61010, 1000V CAT III / 600V CAT IV; IEC 61010-031; IEC 61326; Pollution Degree 2
     

    Current Clamp Options
    Current Sensor Jaw/Coil Size Measurement Range
    008B Small Tip Current Clamp 7.5mm × 13mm 10mA–10.0A
    040B Round-Jaw Current Clamp 35mm × 40mm 0.10A–100A
    068B Round-Jaw Current Clamp 68mm × 68mm 1.0A–1000A
    300F Flexible Coil Current Sensor with Integrator Φ300mm 10A–3000A
    The selectable current sensors allow the XGPQ-300C to accommodate different conductor sizes and current measurement requirements in field applications.
     

    Applications
    The XGPQ-300C Power Quality Analyzer is suitable for:
    • Power quality testing and diagnosis
    • Three-phase electrical system analysis
    • Harmonic measurement and analysis
    • Voltage fluctuation and voltage disturbance analysis
    • Electrical equipment startup and inrush current testing
    • Transformer loading and K-factor analysis
    • Power distribution system maintenance
    • Industrial electrical system monitoring
    • Electrical equipment commissioning
    • Long-term power quality data recording
    • Troubleshooting of abnormal voltage and current conditions
    • Preventive maintenance of power distribution equipment

     

    Application Scenarios
    Power Distribution System Testing
    The XGPQ-300C can simultaneously monitor three-phase voltage and current, allowing technicians to analyze load conditions, power factor, unbalance, harmonics and other power quality parameters.
    Harmonic Analysis
    With measurement capability up to the 50th harmonic, the analyzer can be used to identify harmonic distortion generated by nonlinear loads, power electronic equipment, converters and other electrical devices.
    Electrical Equipment Startup Testing
    The inrush current function captures the startup current of motors, transformers and other electrical equipment, helping engineers evaluate startup characteristics and verify electrical installation capacity.
    Power Quality Troubleshooting
    Transient capture and alarm monitoring help identify voltage sags, swells, interruptions, transient overvoltage, overcurrent, harmonic limit violations and other abnormal conditions.
    Long-Term Power Quality Monitoring
    The trend recording function supports approximately 300 days of data recording under the specified 20-parameter, 5-second recording configuration, making the instrument suitable for extended monitoring and trend analysis.

     

    XGPQ-300C Measurement Capability
  • FAQ
    What is the XGPQ-300C Power Quality Analyzer used for?
    The XGPQ-300C is designed for three-phase power quality measurement, analysis, troubleshooting and long-term recording. It can measure voltage, current, power, energy, power factor, harmonics, THD, flicker, unbalance and other electrical parameters.
    How many voltage and current channels does the analyzer have?
    The XGPQ-300C provides 4 voltage channels and 4 current channels, allowing simultaneous measurement of three-phase voltage/current and neutral-line parameters.
    How many harmonics can the XGPQ-300C measure?
    The analyzer can measure harmonics from the fundamental component through the 50th harmonic and display harmonic content using bar charts.
    Can the XGPQ-300C capture transient power disturbances?
    Yes. The transient capture function can detect voltage/current fluctuations, swells, sags, short interruptions, transient overvoltage, inrush current and instantaneous waveform distortion. Up to 150 groups of transient waveforms can be stored.
    Can it measure motor or equipment startup current?
    Yes. The dedicated inrush current monitoring mode can record approximately 100 seconds of startup data and display current and voltage waveforms and inrush current curves.
    How long can the analyzer record trend data?
    Under the specified configuration of 20 parameters recorded every 5 seconds, the instrument can record data for approximately 300 days.
    How many alarm conditions can be configured?
    Up to 40 alarm monitoring groups can be configured, with up to 12,800 alarm logs stored.
    Can measurement data be transferred to a computer?
    Yes. The instrument communicates with a computer through a USB interface. The software can display and retrieve waveforms, transient records, trend data, alarm logs and screenshots.
    What current clamps are available?
    The XGPQ-300C can be configured with 008B, 040B, 068B current clamps and a 300F flexible coil current sensor. The maximum current measurement range with the 300F sensor is 10A–3000A.
    Is the XGPQ-300C suitable for field testing?
    Yes. The instrument is specifically designed for on-site testing and features a compact structure, anti-vibration protective housing, rechargeable battery, large color display and bilingual operation interface.
    What safety category does the XGPQ-300C comply with?
    The instrument is specified for 1000V CAT III / 600V CAT IV and complies with IEC 61010, IEC 61010-031 and IEC 61326 requirements, with Pollution Degree 2.
     
     

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com