Position: Home > > Industry specific instrument > electric equipment > Power detection equipment > SYS320B Wireless high-voltage voice phase checker for High-voltage line measurement

SYS320B Wireless high-voltage voice phase checker for High-voltage line measurement

Product ID:DLSBdljc003

Price: Please inquire PDF Format
Supply Ability:200 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberSYS320B
    Brand NameYANGZHOUSUOYA
    Payment TermsT/T, paypal
    SYS320B wireless high and low voltage nuclear phase current meter
     
    Introduction:
         SYS320B wireless high-voltage nuclear phase current phase meter is also known as full intelligent wireless high-voltage voice nuclear phase meter, wireless high-voltage nuclear phase meter, wireless high-voltage nuclear phase current meter, etc., consisting of wireless receiver, hook detector, telescopic insulation rod and so on. Hook detectors are different from traditional nuclear phase instruments in that they need to be connected with metal detection hooks. Instead, they use an integrated hook design with built-in double-layer flexible coils that can simultaneously test high-voltage current, phase, phase, phase sequence, frequency, etc. The coil test has wide current range, good linearity and high precision. It can be directly tested on the line, saving time and effort. It can hook 168mm wire or 168mm×245mm busbar. The receiver adopts 3.5-inch true color LCD screen and displays on the same screen. Nuclear phase results, current, phase, frequency, etc., with vector diagram indication, "X signal normal, Y signal normal, in phase, out of phase" and other voice prompts, clear and intuitive. The open nuclear phase of the ground can be up to 160m away. It can fully intelligent nuclear phase for voltage lines from 100V to 550kV. The bare wires below 35kV can directly contact the nuclear phase. The bare wires above 35kV use non-contact nuclear phase, non-contact core. The phase is to gradually bring the hook detector close to the wire to be tested. When the electric field signal is sensed, the nuclear phase can be completed, so that it is safer to directly contact the high voltage wire! The nuclear phase meter also has the functions of high-voltage electroscope, high-voltage phase meter and high-voltage phase sequence meter, which can be used for electroscope, phase sequence test, transformer group judgment and so on.
           The SYS320B X detector has high and low voltage current and leakage current test functions. The current measurement range is 0~20000A, which meets nuclear phase, current, leakage current, phase, phase sequence and electroscope test. It can also be used for high voltage cable. Leakage inspection: H-detector with test current function is hooked on the cable and patrol along the line. If the receiver changes from a large current display to a small current or no current display, this point is the cable leakage point.
    Technical Parameters:
    Function: High and low voltage wireless voice nuclear phase, current, leakage current, frequency, phase, phase sequence, electroscope test; multi-core cable leakage inspection, etc.
    Power: DC 3.7V rechargeable lithium battery, USB charging interface, continuous operation for about 10 hours
    Test method: Hook detector, can be hung on the line or hooked up the wire test
    Transmission method: 315MHz, 433MHz wireless transmission
    Nuclear phase distance: 160 meters
    Display mode: 3.5 inch true color LCD display
    Measurable wire diameter: Ф168mm wire, or 168mm×245mm busbar
    Range: Nuclear phase voltage level: AC 100V ~ 550kV
    Phase: 0.0° to 360.0°
    Frequency: 45Hz ~ 75Hz
    Current: 0.00A ~ 20000A
    Resolution: 0.1°; 0.1Hz; 10mA
    Accuracy: Phase: ≤ ± 10 ° (23 ° C ± 5 ° C, below 80% RH)
    Frequency: ≤±2Hz (23°C±5°C, 80% RH or less)
    Current: 0 ~ 6000A, ± 3% ± 5dgt; 6000A ~ 2000A, ± 4% ± 5dgt;
    (23 °C ± 5 ° C, 80% RH or less)
    Differentiate qualitative: in phase: -30 ° ~ 30 °; out of phase: 90 ° ~ 150 ° and 210 ° ~ 270 °
    Voice function: In-phase, out-of-phase, normal X signal, normal Y signal, etc.
    Insulation rod size: about 5m after stretching; about 1m (5 knots) after shrinking
    Data Storage: 9999 Group
    Nuclear phase: Contact nuclear phase: bare wire below 35kV, or wire with safety insulation sheath below 110kV directly in contact with the nuclear phase. (with insulation rod operation)
    Non-nuclear phase: bare wire above 35kV, or non-contact core phase above 110kV. (with insulation rod operation)
    Shift: Automatic shifting
    Position error: Influence of wire position error when testing current: no position error in zone A; increase of 0.2% in zone B; increase of 2% in zone C (see figure below)
    Sampling rate: 2 times / sec
    Meter size: Hook detector: length and width 310mm × 270mm × 52mm
    Receiver: length, width, thickness, 250mm × 100mm × 40mm
    Backlight control: Press the up and down arrow keys to adjust the backlight brightness
    Inductance intensity control: According to the induced electric field strength, the detector can automatically control the magnification, which is convenient for the nuclear phase in densely packed places.
    Data hold: Press the HOLD button to hold the data in test mode, then press the HOLD button to cancel the hold.
    Exit function: Press ESC to exit the current function interface and return to the previous directory.
    Data review: After pressing ENTER to enter the data review mode, press the arrow keys to scroll through the stored data.
    No signal indication: The “----” symbol is displayed dynamically when the receiver does not receive the transmission signal.
    Auto power off: After about 15 minutes of power on, the meter automatically shuts down to reduce battery consumption.
    Battery voltage: When the battery voltage is lower than 3.2V
    Detector: The power indicator light flashes slowly to remind you to charge
    Receiver: battery voltage low symbol display, reminder charging
    Rated current: Detector: 35mA max; Receiver: 300mA max
    Instrument quality: Hook detector: 496g (with battery)
    Receiver: 395g (with battery)
    Insulation rod: 1.45kg
    Total mass: 13.5kg (including instrument box)
  • Introduction:
         SYS320B wireless high-voltage nuclear phase current phase meter is also known as full intelligent wireless high-voltage voice nuclear phase meter, wireless high-voltage nuclear phase meter, wireless high-voltage nuclear phase current meter, etc., consisting of wireless receiver, hook detector, telescopic insulation rod and so on. Hook detectors are different from traditional nuclear phase instruments in that they need to be connected with metal detection hooks. Instead, they use an integrated hook design with built-in double-layer flexible coils that can simultaneously test high-voltage current, phase, phase, phase sequence, frequency, etc. The coil test has wide current range, good linearity and high precision. It can be directly tested on the line, saving time and effort. It can hook 168mm wire or 168mm×245mm busbar. The receiver adopts 3.5-inch true color LCD screen and displays on the same screen. Nuclear phase results, current, phase, frequency, etc., with vector diagram indication, "X signal normal, Y signal normal, in phase, out of phase" and other voice prompts, clear and intuitive. The open nuclear phase of the ground can be up to 160m away. It can fully intelligent nuclear phase for voltage lines from 100V to 550kV. The bare wires below 35kV can directly contact the nuclear phase. The bare wires above 35kV use non-contact nuclear phase, non-contact core. The phase is to gradually bring the hook detector close to the wire to be tested. When the electric field signal is sensed, the nuclear phase can be completed, so that it is safer to directly contact the high voltage wire! The nuclear phase meter also has the functions of high-voltage electroscope, high-voltage phase meter and high-voltage phase sequence meter, which can be used for electroscope, phase sequence test, transformer group judgment and so on.
           The SYS320B X detector has high and low voltage current and leakage current test functions. The current measurement range is 0~20000A, which meets nuclear phase, current, leakage current, phase, phase sequence and electroscope test. It can also be used for high voltage cable. Leakage inspection: H-detector with test current function is hooked on the cable and patrol along the line. If the receiver changes from a large current display to a small current or no current display, this point is the cable leakage point.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com