    Laser532-1HSU 532nm Raman Stable Spectrum USB-Controlled Laser
     
    Product Introduction
    The Laser532-1HSU is a 532nm semiconductor-pumped stable-spectrum laser module designed specifically for Raman spectroscopy and other optical analysis applications. Based on DPSS (Diode-Pumped Solid-State) laser technology, it provides narrow-linewidth, stable-spectrum, and stable-power laser output required by Raman spectrometers and spectral analysis instruments.
    The laser module integrates a photodetector (PD) and TEC temperature-control module to improve spectral and power stability. An internal ARM-based digital MCU implements digital PID control, while optimized optical coupling and highly integrated electronics enable convenient USB software control.
    The output power can be digitally adjusted from 0 to 100mW, allowing users to select an appropriate excitation power according to different samples and measurement requirements.

     


    Performance Features
    •  532nm Raman excitation laser designed for Raman spectroscopy applications.
    •  DPSS technology provides stable and narrow-linewidth laser output.
    •  Narrow linewidth <0.1nm for spectral analysis applications.
    •  Stable spectrum and stable power for consistent Raman excitation.
    •  0–100mW adjustable output power for flexible sample measurement.
    •  USB software control enables convenient digital power adjustment.
    •  ARM digital MCU with optimized digital PID control.
    • Integrated PD photodetection and TEC temperature control for improved stability.
    •  Power setting and digital display accuracy within 3%.
    •  Built-in calibration program supports accurate output-power control.
    •  Compact and lightweight design: 180 × 44 × 42mm, 230g.
    •  Long operating life of up to 5,000 hours.
    •  Low power consumption and compact construction.

     


    Working Principle
    The Laser532-1HSU uses DPSS technology to generate a 532nm laser output suitable for Raman excitation. A semiconductor pump source drives the solid-state laser process to produce the required laser wavelength.
    The integrated PD photodetector monitors the laser output, while the TEC cooling module controls the operating temperature of the laser system. The ARM-based MCU uses digital PID algorithms to regulate the laser parameters and maintain stable optical output.
    The optimized optical coupling structure improves the efficiency and stability of the optical system. Through the USB software interface, users can digitally control the output power from 0 to 100mW. The built-in calibration program helps maintain consistency between the set power and actual laser output.
    During Raman spectroscopy, the stable 532nm laser is directed onto the sample as the excitation source. The resulting Raman scattering signal can then be collected and analyzed by the corresponding spectrometer.

     


    Technical Specifications
    Parameter Specification
    Model Laser532-1HSU
    Laser Type Semiconductor-pumped DPSS laser
    Application Raman spectroscopy / spectral analysis
    Excitation Wavelength 532 nm ± 0.5 nm
    Linewidth <0.1 nm
    Output Power 0–100 mW, adjustable
    Power Stability <3% RMS (2 hrs)
    Power Control USB software control
    Control System ARM digital MCU
    Temperature Control Integrated TEC
    Optical Monitoring Integrated PD
    Laser Lifetime 5,000 hours
    Output Interface SMA905
    Warm-Up Time 15 min
    Power Supply Voltage 5V
    Dimensions 180 × 44 × 42 mm
    Weight 230 g
    Operating/Storage Temperature 0–45°C
    Operating/Storage Humidity 5–80%
     


    Application Scenarios
    The Laser532-1HSU 532nm laser module is suitable for:
    •  Raman spectroscopy
    •  Raman spectrometer excitation
    •  Spectral analysis instruments
    •  Material characterization
    •  Chemical and molecular analysis
    •  Optical research
    •  Laboratory spectroscopy systems
    •  Laser-based analytical instruments
    •  Research requiring stable 532nm laser excitation

     


    Laser532-1HSU vs. Conventional 532nm Laser Sources
    Feature Laser532-1HSU Conventional 532nm Laser Source
    Laser Technology DPSS Depends on source
    Wavelength 532 nm ± 0.5 nm Varies by product
    Linewidth <0.1 nm Depends on source
    Output Power 0–100mW adjustable Depends on model
    Power Stability <3% RMS (2 hrs) Depends on source
    Spectrum Stability Designed for stable-spectrum output Depends on design
    USB Software Control Supported Not always available
    Digital PID ARM MCU-based Depends on system
    Temperature Control Integrated TEC Depends on source
    Optical Monitoring Integrated PD Depends on source
    Output Interface SMA905 Varies
    Lifetime Up to 5,000h Depends on source
    Size 180 × 44 × 42mm Varies
     


    FAQ
    1.  What wavelength does the Laser532-1HSU provide?
    The Laser532-1HSU provides a 532nm laser output with a wavelength specification of 532nm ±0.5nm.
    2. Is the Laser532-1HSU suitable for Raman spectroscopy?
    Yes. It is specifically designed as a 532nm Raman excitation laser module for Raman spectroscopy and spectral analysis applications.
    3. What is the laser linewidth?
    The specified linewidth is less than 0.1nm, supporting narrow-linewidth laser excitation for spectral analysis.
    4. Can the laser output power be adjusted?
    Yes. The output power can be adjusted from 0 to 100mW through the USB software control system.
    5. How is the laser power controlled?
    The laser incorporates an ARM digital MCU and digital PID control, with a built-in calibration program for accurate power regulation.
    6. What is the function of the PD and TEC modules?
    The integrated PD monitors optical output, while the TEC provides temperature control to help maintain stable laser spectral and power characteristics.
    7. What is the power stability of the Laser532-1HSU?
    The specified power stability is less than 3% RMS over 2 hours.
    8. How long is the expected laser lifetime?
    The specified laser lifetime is approximately 5,000 hours.
    9. What is the laser output interface?
    The Laser532-1HSU uses an SMA905 optical output interface.
    10. What power supply does the module require?
    The specified power supply voltage is 5V.


  • FAQ
    1.  What wavelength does the Laser532-1HSU provide?
    The Laser532-1HSU provides a 532nm laser output with a wavelength specification of 532nm ±0.5nm.
    2. Is the Laser532-1HSU suitable for Raman spectroscopy?
    Yes. It is specifically designed as a 532nm Raman excitation laser module for Raman spectroscopy and spectral analysis applications.
    3. What is the laser linewidth?
    The specified linewidth is less than 0.1nm, supporting narrow-linewidth laser excitation for spectral analysis.
    4. Can the laser output power be adjusted?
    Yes. The output power can be adjusted from 0 to 100mW through the USB software control system.
    5. How is the laser power controlled?
    The laser incorporates an ARM digital MCU and digital PID control, with a built-in calibration program for accurate power regulation.
    6. What is the function of the PD and TEC modules?
    The integrated PD monitors optical output, while the TEC provides temperature control to help maintain stable laser spectral and power characteristics.
    7. What is the power stability of the Laser532-1HSU?
    The specified power stability is less than 3% RMS over 2 hours.
    8. How long is the expected laser lifetime?
    The specified laser lifetime is approximately 5,000 hours.
    9. What is the laser output interface?
    The Laser532-1HSU uses an SMA905 optical output interface.
    10. What power supply does the module require?
    The specified power supply voltage is 5V.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com