Position: Home > > Environmental monitoring and analysis > Water organic pollutants > TOC analyzer > KN-TOC20 Total Organic Carbon Tester for Organic pollution degree

KN-TOC20 Total Organic Carbon Tester for Organic pollution degree

Product ID:HSYJtoc031

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberKN-TOC20
    Brand NameKENUOKEYI
    Payment TermsT/T, paypal
    KN-TOC20 Total Organic Carbon Tester
     
    Features:
     1. Automatic micro-injection, the amount of sample injection is controllable, no pollutants are generated in the whole test process, and no harm to humans and the environment
    2. The advanced micro-signal processing system has several advantages such as online setting, real-time monitoring, self-calibration, flow rate control, etc., ensuring superior instrument performance and safe operation
    3. The high-temperature cracking device is equipped with a special catalyst with strong oxidation ability. According to the properties of different samples, different temperatures can be set to maximize the digestion of the samples and make the measurement data more accurate and reliable.
    4. The power of the refrigeration module can be adjusted according to the size of the injection volume, which improves the dehydration efficiency of the entire system, ensures the dryness of the gas entering the detector, and ensures that the detection system has high resolution and durability
    5. Advanced real-time detection software: the sample curve is drawn at the same coordinate, and the repeatability is displayed intuitively; the running status of the instrument is monitored at all times, and the difference between the measured parameters and the set parameters is compared
    6. Automatic leak detection control system: real-time detection of gas flow, with alarm settings at the same time, to prevent gas leakage, to maximize the safety of operators and instruments
    7. The application of advanced flow rate control signal processing technology can shield the influence of flow rate fluctuations and ensure stable and accurate readings
    8. Adopting the four-in-one technology of heating, cooling, dehydrating and liquid level monitoring in the TIC reaction tank, it is very effective to remove the influence of water vapor on the detection results; at the same time, the air flow and liquid flow path are more simplified, saving a lot of analysis time and making the detection Line widening
    9. The detector uses a 24bit digital solution to extend the detection range, and the control system uses 32bin signal processing technology to greatly improve the performance of the instrument and make the detection limit lower, which can meet most of the standard detection limits and determinations Lower limit requirements, high test accuracy and precision, high sensitivity
    10. The design and application of the internationally advanced non-dispersive infrared detector (NDIR), while adopting special surface treatment technology to make the detection more accurate and reliable
    11. Using 24-bit A/D conversion technology, the data is more stable, the noise is lower, the detection range is wider, and the speed is faster
    The use of 12.32bin signal processing technology makes the performance of the instrument more reliable, and at the same time has a good constant temperature function, and high precision of temperature difference control
    13. Modular design, quick and convenient assembly, maintenance and repair
     Technical Parameters:
    Instrument model: KN-TOC20
    Detector: NDIR (non-dispersive infrared detection)
    Measurement items: TC, TIC, TOC, NPOC
    Digestion principle: high temperature catalytic oxidation
    Mode of operation: computer control
    Gas requirements: Oxygen: ≥99.995%
    Measuring range: 0-30000mg/l direct measurement 0-2000mg/L
    Detection limit: 50ug/l
    Repeatability: <3%
    Indication error: ≤2%
    Analysis time: 1-4 minutes
    Digestion temperature: 0-1000 (adjustable)
    Sample temperature: 1-95
    Particle size: ≤0.2mm
    Maximum salt tolerance: 85g/L direct measurement 0-1000mg/L
    Power supply: 220±10V AC, 50/60HZ, 1kW
    Size: 430*465*450mm
    Weight: 31Kg
     

     
  • Features:
     1. Automatic micro-injection, the amount of sample injection is controllable, no pollutants are generated in the whole test process, and no harm to humans and the environment
    2. The advanced micro-signal processing system has several advantages such as online setting, real-time monitoring, self-calibration, flow rate control, etc., ensuring superior instrument performance and safe operation
    3. The high-temperature cracking device is equipped with a special catalyst with strong oxidation ability. According to the properties of different samples, different temperatures can be set to maximize the digestion of the samples and make the measurement data more accurate and reliable.
    4. The power of the refrigeration module can be adjusted according to the size of the injection volume, which improves the dehydration efficiency of the entire system, ensures the dryness of the gas entering the detector, and ensures that the detection system has high resolution and durability
    5. Advanced real-time detection software: the sample curve is drawn at the same coordinate, and the repeatability is displayed intuitively; the running status of the instrument is monitored at all times, and the difference between the measured parameters and the set parameters is compared
    6. Automatic leak detection control system: real-time detection of gas flow, with alarm settings at the same time, to prevent gas leakage, to maximize the safety of operators and instruments
    7. The application of advanced flow rate control signal processing technology can shield the influence of flow rate fluctuations and ensure stable and accurate readings
    8. Adopting the four-in-one technology of heating, cooling, dehydrating and liquid level monitoring in the TIC reaction tank, it is very effective to remove the influence of water vapor on the detection results; at the same time, the air flow and liquid flow path are more simplified, saving a lot of analysis time and making the detection Line widening
    9. The detector uses a 24bit digital solution to extend the detection range, and the control system uses 32bin signal processing technology to greatly improve the performance of the instrument and make the detection limit lower, which can meet most of the standard detection limits and determinations Lower limit requirements, high test accuracy and precision, high sensitivity
    10. The design and application of the internationally advanced non-dispersive infrared detector (NDIR), while adopting special surface treatment technology to make the detection more accurate and reliable
    11. Using 24-bit A/D conversion technology, the data is more stable, the noise is lower, the detection range is wider, and the speed is faster
    The use of 12.32bin signal processing technology makes the performance of the instrument more reliable, and at the same time has a good constant temperature function, and high precision of temperature difference control
    13. Modular design, quick and convenient assembly, maintenance and repair
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com