HWP11-10S Foam Aerosol Flammability Tester

Product ID:HZWHqtwh003

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberHWP11-10S
    Brand NameHZYANGYI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    HWP11-10S Foam Aerosol Flammability Tester
    Product Introduction
    The HWP11-10S Foam Aerosol Flammability Tester is designed to evaluate the flammability of aerosol products discharged as foam, gel, or paste. It automatically detects maximum flame height and burning duration, providing objective and repeatable data for aerosol flammability and safety evaluation.
    The HWP11-10S complies with Section 31.6, Flammability of Aerosol Foams, in the UN Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, as well as GB/T 21632-2008, Test Method for Flammability of Dangerous Goods—Aerosol Foams.
    The instrument integrates a display/control unit with an automated detection mechanism. Test parameters can be configured through the touchscreen, while test data and reports can be stored and reviewed automatically.

     

    Key Features
    •  Automatic flame height and burning-time detection for improved testing consistency.
    •  High-sensitivity photoelectric detection technology with a burning response time of ≤6 ms.
    •  Flame height detection range of 0–235 mm with 5 mm resolution.
    •  Special stacked structural design reduces background-light interference.
    •  Automatic flame-height identification for irregular flame shapes.
    •  8-inch LCD touchscreen for intuitive operation and real-time test status.
    •  Real-time test animation and visual monitoring.
    • High-precision temperature and humidity module for monitoring test conditions.
    •  Embedded processor with Windows CE operating system.
    • Fully automated test workflow with parameter setting, data storage, and report functions.

     

    Working Principle
    The aerosol sample is discharged as specified for the test and ignited using a gas igniter. During combustion, the instrument uses a high-sensitivity photoelectric detection system to monitor the flame.
    The optical detection module continuously identifies flame development and automatically determines the maximum flame height and combustion duration. Temperature and relative humidity are monitored simultaneously to document environmental conditions. The embedded control system processes the measured signals, displays the test status in real time, and stores the results for report generation.

     

    Technical Parameters
    Parameter Specification
    Model HWP11-10S
    Application Foam, gel and paste aerosol flammability testing
    Applicable Standard UN Manual of Tests and Criteria, Section 31.6; GB/T 21632-2008
    Working Environment -5°C to 45°C; <95% RH
    Flame Height Detection Range 0–235 mm
    Flame Height Resolution 5 mm
    Combustion Detection Response Time ≤6 ms
    Ambient Temperature Measurement Range -10°C to +60°C
    Temperature Measurement Accuracy ±0.5°C
    Humidity Measurement Range 5–95% RH
    Humidity Measurement Accuracy ±5.0% RH
    Ignition Method Gas igniter
    Supporting Glass Diameter Φ150 mm
    Display 8-inch LCD touchscreen
    Operation Automatic testing, data storage and report generation
     

    Applications
    The HWP11-10S is suitable for flammability evaluation of:
    •  Foam aerosol products
    •  Gel and paste aerosol products
    •  Household aerosol formulations
    •  Personal-care and cosmetic aerosols
    •  Industrial aerosol products
    •  Dangerous-goods classification and safety testing
    •  Aerosol product R&D and quality control
    •  Third-party testing laboratories and regulatory inspection

     

    HWP11-10S vs. Manual Aerosol Flammability Testing
    Feature HWP11-10S Manual Testing
    Flame Height Measurement Automatic Manual
    Burning Time Detection Automatic Manual timing
    Flame Recognition Photoelectric Operator observation
    Environmental Monitoring Temperature & humidity monitored Usually separate
    Background-Light Interference Reduced by optical structure More susceptible
    Data Recording Automatic storage Manual recording
    Test Reports Automatic generation Manual preparation
    Repeatability High Operator-dependent
    Test Workflow Automated Labor-intensive
     

    FAQ
    1.  What does the HWP11-10S test?
    It evaluates the flammability of aerosols discharged in the form of foam, gel, or paste, including flame height and burning duration.
    2. Which standards does the tester comply with?
    It is designed according to UN Manual of Tests and Criteria Section 31.6 and GB/T 21632-2008.
    3.  How is flame height measured?
    A high-sensitivity photoelectric detection system automatically identifies the flame and determines its maximum height.
    4. What is the flame height measurement range?
    The detection range is 0–235 mm, with a resolution of 5 mm.
    5. Does the instrument automatically measure burning time?
    Yes. The combustion detection system automatically records burning duration with a response time of ≤6 ms.
    6. Can environmental conditions be monitored during testing?
    Yes. The instrument continuously monitors temperature and relative humidity to help maintain and document stable test conditions.
    7. Is manual intervention required during the test?
    The test workflow is highly automated. Users can configure parameters, start testing, review results, store data, and generate reports through the touchscreen.
    8. What is the ignition method?
    The instrument uses a gas igniter for sample ignition.

     

     
  • FAQ
    1.  What does the HWP11-10S test?
    It evaluates the flammability of aerosols discharged in the form of foam, gel, or paste, including flame height and burning duration.
    2. Which standards does the tester comply with?
    It is designed according to UN Manual of Tests and Criteria Section 31.6 and GB/T 21632-2008.
    3.  How is flame height measured?
    A high-sensitivity photoelectric detection system automatically identifies the flame and determines its maximum height.
    4. What is the flame height measurement range?
    The detection range is 0–235 mm, with a resolution of 5 mm.
    5. Does the instrument automatically measure burning time?
    Yes. The combustion detection system automatically records burning duration with a response time of ≤6 ms.
    6. Can environmental conditions be monitored during testing?
    Yes. The instrument continuously monitors temperature and relative humidity to help maintain and document stable test conditions.
    7. Is manual intervention required during the test?
    The test workflow is highly automated. Users can configure parameters, start testing, review results, store data, and generate reports through the touchscreen.
    8. What is the ignition method?
    The instrument uses a gas igniter for sample ignition.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com