Position: Home > > Industrial on-line and process control > Industrial chromatograph > On-line gas chromatography > HA-9660-Plus Electronic Specialty Gas Chromatograph

HA-9660-Plus Electronic Specialty Gas Chromatograph

Product ID:GYSP002

Price: Please inquire PDF Format
Supply Ability:50 SETS/MONTH
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberHA-9660-Plus
    Brand NameSHHUAAI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    HA-9660-Plus Electronic Specialty Gas Chromatograph
     
    Product Introduction
    The HA-9660-Plus Electronic Specialty Gas Chromatograph is designed for ultra-trace impurity analysis in electronic specialty gases and other high-purity gas applications. It helps manufacturers monitor trace contaminants, evaluate gas quality, and support quality control for demanding industrial processes.
    Equipped with the PDHID S Pro+ high-sensitivity helium ionization detector, the system provides strong responses to a broad range of inorganic and organic compounds. It is particularly suitable for high-purity gas analysis, with detector sensitivity described as reaching the ng/g (ppb) level, depending on the analyte and analytical conditions.
    The HA-9660-Plus features electrical and gas-path separation to help reduce electromagnetic interference and improve operational safety. Available in single-channel and multi-channel configurations, it can be adapted to different analytical workloads, from individual gas testing to multi-component and multi-sample analysis.

     


     Performance Features
    • Ultra-trace impurity analysis: Supports detection of trace contaminants in electronic specialty gases and high-purity gases.
    •  PDHID S Pro+ detector: High sensitivity and broad compound response for demanding gas analysis applications.
    •   Electrical and gas-path separation: Isolates electrical modules from gas-path modules to help reduce electromagnetic interference and limit potential cross-contamination risks.
    •  Flexible channel configurations: Single-channel systems support focused analysis, while multi-channel configurations accommodate broader analytical requirements.
    • High-purity gas quality control: Helps evaluate gas purity and monitor impurities relevant to semiconductor and specialty gas production.
    •  Research and process development: Supports studies of gas composition and reaction processes to help optimize specialty gas preparation.

     


     Working Principle
    The HA-9660-Plus uses gas chromatography to separate components in a gas sample according to their interactions with the chromatographic column. As the separated components leave the column, the PDHID S Pro+ helium ionization detector responds to the compounds and generates signals for chromatographic analysis.
    The resulting chromatogram is used to identify and quantify target impurities according to the analytical method, calibration data, and applicable operating conditions. This approach supports ultra-trace impurity monitoring in high-purity gases.
    The electrical and gas-path separation design helps isolate sensitive electronic components from the sample flow path, supporting stable operation and reducing potential interference.

     


    Technical Specifications
    Parameter Description
    Model HA-9660-Plus
    Product Type Electronic specialty gas chromatograph
    Primary Application Ultra-trace impurity analysis in electronic specialty gases
    Detector PDHID S Pro+ helium ionization detector
    Detector Sensitivity Reported at ng/g (ppb) level; actual performance depends on analyte and analytical conditions
    Compound Response Broad response to many inorganic and organic compounds
    Channel Configuration Single-channel or multi-channel
    Design Feature Electrical modules separated from gas-path modules
    Main Functions Trace impurity monitoring, gas quality control, multi-component analysis
    Typical Users Electronic gas manufacturers, semiconductor facilities, analytical laboratories, R&D teams
    Note: Detailed operating ranges, chromatographic column options, gas consumption, repeatability, detection limits for specific compounds, and instrument dimensions should be confirmed with the manufacturer for the selected configuration.
     


    Application Scenarios
    • Semiconductor manufacturing: Monitoring trace impurities in high-purity process gases.
    •  Electronic specialty gas production: Evaluating gas quality and supporting production quality control.
    • High-purity gas analysis: Detecting low-level inorganic and organic contaminants.
    •  Gas preparation process optimization: Supporting research into gas reactions and purification processes.
    •  Analytical laboratories: Conducting trace gas composition analysis and method development.
    • Research and development: Investigating gas composition and analytical performance under controlled conditions.

     


    HA-9660-Plus vs. Conventional Gas Chromatographs
    Comparison Item HA-9660-Plus Conventional Gas Chromatograph
    Main Focus Electronic specialty gases and ultra-trace impurities Depends on detector and system configuration
    Detector Option PDHID S Pro+ helium ionization detector May use TCD, FID, or other detectors
    Trace Analysis Designed for high-sensitivity, low-level impurity analysis Sensitivity varies by detector and method
    Gas-Path Design Electrical and gas-path separation Design varies by instrument
    Channel Options Single-channel and multi-channel configurations Depends on model
    Typical Applications High-purity gases, semiconductor processes, specialty gas QC General gas composition analysis and routine laboratory testing
     


     Frequently Asked Questions
    Q1: What is the HA-9660-Plus used for?
    It is designed for ultra-trace impurity analysis in electronic specialty gases and other high-purity gas applications.
    Q2: What detector does the HA-9660-Plus use?
    It is equipped with the PDHID S Pro+ high-sensitivity helium ionization detector.
    Q3: What does ppb-level sensitivity mean?
    It refers to analysis at very low concentrations, around parts per billion by mass where applicable. Actual detection performance depends on the target compound, sample matrix, method, and operating conditions.
    Q4: Can it analyze both inorganic and organic compounds?
    The PDHID S Pro+ detector responds to a broad range of inorganic and organic compounds. Suitability for a particular compound must be verified using the relevant analytical method.
    Q5: Is the HA-9660-Plus suitable for semiconductor applications?
    Yes. It is designed for high-purity electronic gas analysis and can support trace impurity monitoring relevant to semiconductor manufacturing.
    Q6: What is the benefit of electrical and gas-path separation?
    The design helps reduce electromagnetic interference and separates electronic modules from the sample gas path, supporting stable analysis and helping limit contamination risks.
    Q7: Is a single-channel or multi-channel configuration available?
    Both configurations are available. The appropriate option depends on the number of target gases, components, and samples to be analyzed.
    Q8: Can the instrument be used for R&D?
    Yes. It can support gas composition studies, analytical method development, and research related to specialty gas preparation and purification.
    Q9: What information is needed to select a suitable configuration?
    Provide the gas types, target impurities, required detection limits, sample pressure and flow conditions, and expected sample throughput. These details help determine the appropriate channel configuration and analytical method.


  • Frequently Asked Questions
    Q1: What is the HA-9660-Plus used for?
    It is designed for ultra-trace impurity analysis in electronic specialty gases and other high-purity gas applications.
    Q2: What detector does the HA-9660-Plus use?
    It is equipped with the PDHID S Pro+ high-sensitivity helium ionization detector.
    Q3: What does ppb-level sensitivity mean?
    It refers to analysis at very low concentrations, around parts per billion by mass where applicable. Actual detection performance depends on the target compound, sample matrix, method, and operating conditions.
    Q4: Can it analyze both inorganic and organic compounds?
    The PDHID S Pro+ detector responds to a broad range of inorganic and organic compounds. Suitability for a particular compound must be verified using the relevant analytical method.
    Q5: Is the HA-9660-Plus suitable for semiconductor applications?
    Yes. It is designed for high-purity electronic gas analysis and can support trace impurity monitoring relevant to semiconductor manufacturing.
    Q6: What is the benefit of electrical and gas-path separation?
    The design helps reduce electromagnetic interference and separates electronic modules from the sample gas path, supporting stable analysis and helping limit contamination risks.
    Q7: Is a single-channel or multi-channel configuration available?
    Both configurations are available. The appropriate option depends on the number of target gases, components, and samples to be analyzed.
    Q8: Can the instrument be used for R&D?
    Yes. It can support gas composition studies, analytical method development, and research related to specialty gas preparation and purification.
    Q9: What information is needed to select a suitable configuration?
    Provide the gas types, target impurities, required detection limits, sample pressure and flow conditions, and expected sample throughput. These details help determine the appropriate channel configuration and analytical method.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com