Position: Home > > Analytical instruments > Elemental Analyzer > Other elements analyzer > ChemiScope Touch Series Fluorescence and Chemiluminescence Imaging System

ChemiScope Touch Series Fluorescence and Chemiluminescence Imaging System

Product ID:FDqtOther017

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberChemiScope
    Brand NameSHQINXIANG
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    ChemiScope Touch Series Fluorescence and Chemiluminescence Imaging System
     
    Product Introduction
    The ChemiScope Touch Series Fluorescence and Chemiluminescence Imaging System is designed for sensitive image acquisition and quantitative analysis of chemiluminescent and fluorescent samples. Combining advanced detection technology, an intuitive touchscreen interface, and intelligent imaging functions, the system simplifies laboratory imaging workflows and reduces reliance on traditional darkroom environments and hazardous reagents.
    Equipped with a high-sensitivity cooled CCD camera, motorized large-aperture lens, and configurable multi-mode imaging modules, the ChemiScope Touch series supports applications ranging from UV and visible-light imaging to near-infrared fluorescence detection.

     


    Performance Features
    1. Light-Tight, Interference-Resistant Enclosure: The enclosure panels are molded in one piece from high-molecular-weight nano-based environmentally friendly material, while the stainless steel chassis is formed by one-piece stamping to provide consistent construction, reliable light sealing, and resistance to interference.
    2. High-Sensitivity Cooled CCD Camera: Imported cooled CCD technology delivers high sensitivity and a strong signal-to-noise ratio for detecting weak signals and performing quantitative analysis.
    3. Large-Aperture Motorized Lens: High-transmittance motorized lenses with F0.95 or F0.8 apertures provide clear imaging and software-controlled precision focusing.
    4. Automatic Feedback Circuit: The integrated feedback circuit supports remote fault diagnosis and system upgrades.
    5. Automatic Focusing: Intelligent autofocus reduces manual adjustment and the risk of focusing errors.
    6. Multi-Mode Fluorescence Imaging: Multi-band fluorescence modules and an optional 8-position motorized filter wheel support imaging from ultraviolet and visible light to near-infrared wavelengths. Intelligent sample-adaptive settings help optimize imaging parameters.
    7. Non-Damaging LED Blue-Light Transilluminator: Imported LED light sources provide energy-efficient illumination and enable nucleic acid sample observation without the UV-related damage associated with conventional UV exposure.
    8.Convenient Magnetic Interface: A magnetic pin-style connection and touchscreen light-intensity adjustment improve daily operation.
    9.Flexible Data and Control Interface: Users can switch between the integrated touchscreen and an external computer, providing greater flexibility for system operation and data handling.

     


    Working Principle
    The ChemiScope Touch system captures weak optical signals generated by chemiluminescent reactions or fluorescence excitation. Its cooled CCD camera converts incoming photons into electrical signals, which are processed to produce digital images for visualization and quantitative analysis.
    The motorized lens and automatic focusing function help obtain clear images, while optional fluorescence modules and motorized filters enable wavelength-specific imaging. Configurable UV, white-light, and blue-light sample platforms accommodate different sample types and imaging requirements.

     


    Technical Parameters
    ChemiScope 6100 Main Unit
    Parameter Specification
    Camera Type Front-illuminated cooled CCD camera
    CCD Sensor Size 12.49 × 9.99 mm
    Effective Pixels 6.05 megapixels
    Image Resolution 2750 × 2200
    Pixel Size 4.54 × 4.54 μm
    Bit Depth 16-bit (65,536 grayscale levels)
    Quantum Efficiency ≥75%
    Cooling Method Thermoelectric semiconductor cooling
    Cooling Temperature −30°C absolute, adjustable
    Lens F0.95 motorized preset lens
    ChemiScope 6200 Main Unit
    Parameter Specification
    Camera Type Front-illuminated cooled CCD camera
    CCD Sensor Size 12.49 × 9.99 mm
    Effective Pixels 6.05 megapixels
    Image Resolution 2750 × 2200
    Pixel Size 4.54 × 4.54 μm
    Bit Depth 16-bit (65,536 grayscale levels)
    Quantum Efficiency ≥75%
    Cooling Method Thermoelectric semiconductor cooling
    Cooling Temperature Below −30°C absolute, adjustable
    Lens F0.8 motorized preset lens
    Sample Platforms and Optional Modules
    Component Configuration
    Standard UV Platform UV SMART™ shadow-free ultra-thin UV transilluminator
    UV Wavelength 302 nm
    White-Light Platform Optional ultra-thin white-light transilluminator
    Blue-Light Platform Optional ultra-thin blue-light transilluminator, 470 nm
    Motorized Filter Wheel Optional 8-position electric filter wheel
    Fluorescence Modules Optional multi-band fluorescence modules
     


    Application Scenarios
    • Western Blot Imaging: Chemiluminescent signal capture and quantitative protein analysis.
    •  Nucleic Acid Gel Documentation: Imaging of DNA and RNA electrophoresis gels.
    • Fluorescence Imaging: Detection of fluorescently labeled proteins, nucleic acids, and other biological samples.
    • Molecular Biology Research: Image acquisition for gene expression and protein analysis experiments.
    • Life Science Laboratories: Routine imaging and documentation in biotechnology, molecular biology, and biomedical research.
    •   Multi-Wavelength Detection: UV, visible-light, and near-infrared fluorescence imaging with compatible optional modules.

     


    Comparison: ChemiScope 6100 vs. ChemiScope 6200
    Feature ChemiScope 6100 ChemiScope 6200
    CCD Resolution 6.05 MP 6.05 MP
    Image Resolution 2750 × 2200 2750 × 2200
    Pixel Size 4.54 × 4.54 μm 4.54 × 4.54 μm
    Quantum Efficiency ≥75% ≥75%
    Cooling Temperature −30°C absolute, adjustable Below −30°C absolute, adjustable
    Lens Aperture F0.95 F0.8
    Lens Type Motorized preset lens Motorized preset lens
    The ChemiScope 6100 and 6200 share the same listed CCD sensor dimensions, resolution, pixel size, and quantum efficiency. The main specified differences are the cooling temperature and lens aperture. The 6200 features a larger F0.8 aperture and a lower specified cooling temperature.
     


    Frequently Asked Questions
    1. What is the ChemiScope Touch imaging system used for?
    It is designed for chemiluminescence and fluorescence imaging, including Western blot analysis, nucleic acid gel documentation, and molecular biology research.
    2. What is the difference between the ChemiScope 6100 and 6200?
    Both models feature a 6.05-megapixel cooled CCD camera. The 6100 uses an F0.95 motorized lens, while the 6200 uses an F0.8 lens and has a specified cooling temperature below −30°C absolute.
    3. What type of camera does the system use?
    The system uses a front-illuminated cooled CCD camera with 6.05 megapixels, 16-bit image depth, and quantum efficiency of at least 75%.
    4. Can the system perform fluorescence imaging?
    Yes. With optional fluorescence modules and an 8-position motorized filter wheel, it supports multi-band fluorescence imaging across UV, visible, and near-infrared wavelengths.
    5. Does the system support chemiluminescence imaging?
    Yes. Its high-sensitivity cooled CCD camera is designed to capture weak chemiluminescent signals for image analysis and quantification.
    6. Can the system image nucleic acid gels without UV exposure?
    Yes. The optional 470 nm blue-light transilluminator provides a non-damaging illumination option for nucleic acid sample observation.
    7. What sample illumination platforms are available?
    The system includes a 302 nm UV SMART™ transilluminator. Ultra-thin white-light and 470 nm blue-light transilluminators are available as options.
    8. Can the system be operated without an external computer?
    The system supports switching between its integrated touchscreen and an external computer, providing flexible operation options.


  • Frequently Asked Questions
    1. What is the ChemiScope Touch imaging system used for?
    It is designed for chemiluminescence and fluorescence imaging, including Western blot analysis, nucleic acid gel documentation, and molecular biology research.
    2. What is the difference between the ChemiScope 6100 and 6200?
    Both models feature a 6.05-megapixel cooled CCD camera. The 6100 uses an F0.95 motorized lens, while the 6200 uses an F0.8 lens and has a specified cooling temperature below −30°C absolute.
    3. What type of camera does the system use?
    The system uses a front-illuminated cooled CCD camera with 6.05 megapixels, 16-bit image depth, and quantum efficiency of at least 75%.
    4. Can the system perform fluorescence imaging?
    Yes. With optional fluorescence modules and an 8-position motorized filter wheel, it supports multi-band fluorescence imaging across UV, visible, and near-infrared wavelengths.
    5. Does the system support chemiluminescence imaging?
    Yes. Its high-sensitivity cooled CCD camera is designed to capture weak chemiluminescent signals for image analysis and quantification.
    6. Can the system image nucleic acid gels without UV exposure?
    Yes. The optional 470 nm blue-light transilluminator provides a non-damaging illumination option for nucleic acid sample observation.
    7. What sample illumination platforms are available?
    The system includes a 302 nm UV SMART™ transilluminator. Ultra-thin white-light and 470 nm blue-light transilluminators are available as options.
    8. Can the system be operated without an external computer?
    The system supports switching between its integrated touchscreen and an external computer, providing flexible operation options.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com