Position: Home > > Industry specific instrument > Special equipment for packaging industry > Oxygen permeation meter > C230M (2018) Oxygen Transmission Rate Testing System

C230M (2018) Oxygen Transmission Rate Testing System

Product ID:HZBZtyy0004

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberC230M (2018)
    Brand NameJNLANGUANG
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    C230M (2018) Oxygen Transmission Rate Testing System
     
    Product Introduction
    The C230M (2018) Oxygen Transmission Rate (OTR) Testing System is designed to evaluate the oxygen barrier performance of packaging and other materials. Based on a coulometric oxygen sensor and the equal-pressure test method, it is designed with reference to standards such as ISO 15105-2 and ASTM D3985.
    Featuring three integrated test cells, high-sensitivity sensing technology, and an embedded computer control system, the C230M (2018) provides a wide measurement range for materials with high, medium, and low gas barrier properties. Precise temperature, humidity, and gas-flow control support reliable, repeatable oxygen transmission testing.
    It is suitable for films, sheets, paper, packaging, and related materials used in food, pharmaceuticals, medical devices, household chemicals, and photovoltaic and electronics industries.

     


    Performance Features
    •  Wide OTR Measurement Range: Supports standard specimen testing from 0.05 to 5,000 cm³/(m²·d).
    • Three Integrated Test Cells: Enables efficient testing with a patented integrated three-cell design.
    • High-Sensitivity Coulometric Sensor: Supports sensitive oxygen transmission measurements and repeatable results.
    •  Precise Environmental Control: Adjustable test temperature, humidity, and gas flow.
    •  Fast Test Preparation: Short preheating time helps testing conditions reach their setpoints sooner.
    •   Flexible Testing Modes: Expert and rapid test modes accommodate different materials and testing requirements.
    •   No Special Consumable Mixtures Required: Does not require liquid coolant, catalysts, or special gas mixtures.
    •   Built-In Computer Control: Operates without an external computer.
    •  Package Testing Option: Supports package oxygen transmission testing for packages up to 3 L.
    •  Gas-Saving Function: Intelligent gas management helps reduce carrier-gas consumption.
    •   Calibration Support: Reference films are available for system calibration.
    •  Data Management and Connectivity: Ethernet and USB interfaces support data export and system integration.
    • Pharmaceutical Compliance Options: Optional DataShield™ data management, China GMP computer-system management, and 21 CFR Part 11 features.

     


    Working Principle
    The C230M (2018) uses the equal-pressure method combined with coulometric oxygen detection to measure oxygen transmission through a material.
    The specimen separates two test chambers. One side is exposed to oxygen, while the other is swept with high-purity nitrogen as the carrier gas. Oxygen passing through the specimen is transported to the coulometric sensor, which generates an electrical signal proportional to the amount of oxygen detected. The system processes this signal to calculate the oxygen transmission rate (OTR).
    Controlled temperature, humidity, and gas flow help maintain test conditions, allowing users to compare the oxygen barrier properties of packaging materials under defined conditions.

     


    Technical Parameters
    Parameter Specification
    Model C230M (2018)
    Instrument Type Oxygen Transmission Rate (OTR) Testing System
    Test Principle Equal-pressure method with coulometric oxygen sensor
    Reference Standards ISO 15105-2, ASTM D3985
    Standard OTR Range 0.05–5,000 cm³/(m²·d)
    Package OTR Range 0.00025–25 cm³/(pkg·d)
    OTR Resolution 0.001 cm³/(m²·d)
    Repeatability 0.05 cm³/(m²·d) or 2%, whichever is greater
    Test Temperature 10–55°C, ±0.2°C
    Test Humidity 0%, or 5%–90% RH, ±1%
    Number of Test Cells 3
    Specimen Dimensions 108 × 108 mm
    Maximum Specimen Thickness 3 mm
    Standard Test Area 50 cm²
    Carrier Gas 99.999% high-purity nitrogen, supplied by the user
    Gas Supply Pressure ≥0.28 MPa / 40.6 psi
    Gas Connection 1/8-inch metal tubing
    Package Testing Optional, packages up to 3 L
    Data Interfaces Ethernet and USB
    Control System Built-in dedicated computer
    Optional Functions DataShield™; China GMP computer-system management; 21 CFR Part 11 features
    Note: Package testing and regulatory data-management functions are optional configurations. Confirm the required options and compliance documentation with the manufacturer.
     


    Application Scenarios
    •  Food Packaging: Evaluate oxygen barrier properties of films and packaging to support product quality and shelf-life management.
    •  Pharmaceutical Packaging: Test packaging materials used for medicines and other oxygen-sensitive products.
    • Medical Device Packaging: Assess the oxygen barrier performance of compatible packaging materials.
    •  Flexible Packaging: Measure OTR of plastic films, multilayer laminates, and sheets.
    •  Paper and Composite Materials: Evaluate oxygen barrier properties of paper-based and composite packaging.
    • Photovoltaics and Electronics: Test barrier materials used in applications requiring controlled oxygen transmission.
    • Quality Control and R&D: Compare material formulations, verify specifications, and support packaging development.

     


    C230M (2018) vs. Conventional OTR Testers
    Comparison Item C230M (2018) Conventional Basic OTR Tester
    Detection Principle Coulometric sensor with equal-pressure method Depends on model
    Test Cell Configuration Three integrated test cells Depends on model
    Standard OTR Range 0.05–5,000 cm³/(m²·d) Model-dependent
    Temperature Control 10–55°C, ±0.2°C Depends on model
    Humidity Control 0% or 5%–90% RH, ±1% Depends on model
    Package Testing Optional, up to 3 L May be unavailable
    Computer Control Built-in computer May require an external computer
    Gas Consumption Management Intelligent gas-saving function Depends on model
    Data Integration Ethernet and USB Depends on model
    Pharmaceutical Data Compliance Optional GMP and 21 CFR Part 11 features Depends on configuration
     


    Frequently Asked Questions (FAQ)
    1.  What is the C230M (2018) Oxygen Transmission Rate Testing System used for?
    It measures the oxygen transmission rate of packaging materials and other compatible specimens to evaluate their oxygen barrier performance.
    2. Which testing standards does the C230M (2018) reference?
    It is designed with reference to ISO 15105-2 and ASTM D3985. Users should verify the applicable method and instrument configuration for their testing requirements.
    3. What is the oxygen transmission rate measurement range?
    The standard specimen range is 0.05–5,000 cm³/(m²·d). The optional package testing range is 0.00025–25 cm³/(pkg·d).
    4. How many samples can the instrument test?
    The system has three integrated test cells, supporting multi-cell testing. Actual throughput depends on the material, test conditions, and time required to reach a stable result.
    5. Which materials can be tested?
    Compatible materials include plastic films, sheets, paper, laminates, packaging materials, and other materials used in food, pharmaceutical, medical device, and electronics applications.
    6. Can the C230M (2018) test complete packages?
    Yes. Package testing is available as an option for packages up to 3 L.
    7. What gas supply is required?
    The system requires user-supplied nitrogen with a purity of 99.999% and a gas supply pressure of at least 0.28 MPa (40.6 psi).
    8. Does the instrument support pharmaceutical data compliance?
    Optional configurations include China GMP computer-system management and 21 CFR Part 11 features. Confirm the specific functions, documentation, and validation requirements with the manufacturer.
    9. Does the C230M (2018) require an external computer?
    No. It has a built-in dedicated computer control system. Ethernet and USB interfaces are provided for data transfer and integration with other systems.


  • Frequently Asked Questions (FAQ)
    1.  What is the C230M (2018) Oxygen Transmission Rate Testing System used for?
    It measures the oxygen transmission rate of packaging materials and other compatible specimens to evaluate their oxygen barrier performance.
    2. Which testing standards does the C230M (2018) reference?
    It is designed with reference to ISO 15105-2 and ASTM D3985. Users should verify the applicable method and instrument configuration for their testing requirements.
    3. What is the oxygen transmission rate measurement range?
    The standard specimen range is 0.05–5,000 cm³/(m²·d). The optional package testing range is 0.00025–25 cm³/(pkg·d).
    4. How many samples can the instrument test?
    The system has three integrated test cells, supporting multi-cell testing. Actual throughput depends on the material, test conditions, and time required to reach a stable result.
    5. Which materials can be tested?
    Compatible materials include plastic films, sheets, paper, laminates, packaging materials, and other materials used in food, pharmaceutical, medical device, and electronics applications.
    6. Can the C230M (2018) test complete packages?
    Yes. Package testing is available as an option for packages up to 3 L.
    7. What gas supply is required?
    The system requires user-supplied nitrogen with a purity of 99.999% and a gas supply pressure of at least 0.28 MPa (40.6 psi).
    8. Does the instrument support pharmaceutical data compliance?
    Optional configurations include China GMP computer-system management and 21 CFR Part 11 features. Confirm the specific functions, documentation, and validation requirements with the manufacturer.
    9. Does the C230M (2018) require an external computer?
    No. It has a built-in dedicated computer control system. Ethernet and USB interfaces are provided for data transfer and integration with other systems.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006