Position: Home > > Analytical instruments > Electrochemical Equipment > Electrochemical workstation/ constant potential instrument > C002-2 Straight Five-Port Electrochemical Cell – Internal Plug-In Type

C002-2 Straight Five-Port Electrochemical Cell – Internal Plug-In Type

Product ID:FDgzz029

Price: Please inquire PDF Format
Supply Ability:100 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberC002-2
    Brand NameGAOSHIRUILIAN
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    C002-2 Straight Five-Port Electrochemical Cell – Internal Plug-In Type
    Product Introduction
    The C002-2 Straight Five-Port Electrochemical Cell is a high-borosilicate glass sealed three-electrode electrochemical cell designed for laboratory electrochemical research. Its internal plug-in electrode structure allows the working, counter, and reference electrodes to be installed through the PTFE cover while maintaining a highly sealed experimental environment.
    Available in 10 mL to 500 mL capacities, the C002-2 can be configured as a single-layer or double-layer cell. The double-layer version provides circulating-temperature-bath capability for experiments requiring controlled solution temperature. Optional valves and gas inlet/outlet systems support inert-atmosphere protection, while the sealed structure can also be used for vacuum or pressure experiments within specified safety limits.

     

    Key Features
    •  High-borosilicate glass cell body for good chemical and thermal resistance.
    •  Absolute-sealed three-electrode configuration for controlled electrochemical experiments.
    •  Internal plug-in electrode design through the cover, helping maintain a sealed system.
    •  10–500 mL capacity range, with custom sizes available.
    •  Single-layer and double-layer versions available.
    •  Double-layer jacket supports circulating-water temperature control.
    •  PTFE cover provides reliable sealing and chemical resistance.
    •  Optional valves and gas inlet system for inert-gas protection and aeration.
    •  Suitable for vacuum operation; pressure operation is available only under specified configurations and safety limits.
    • Designed specifically for Ag/AgCl reference electrodes; sand-core salt bridges and Luggin capillaries are not supported.

     

    Working Principle
    An electrochemical cell converts electrical and chemical energy through oxidation-reduction reactions at the electrodes. In a typical three-electrode configuration, the working electrode performs the electrochemical reaction, the counter electrode completes the current circuit, and the reference electrode provides a stable reference potential.
    The C002-2 uses a sealed glass chamber to isolate the electrolyte from the external environment. Gas valves can introduce a protective atmosphere, while the double-layer version allows circulating thermostatic water to control the temperature of the electrolyte. Its internal plug-in electrode structure helps maintain a sealed experimental environment during electrochemical measurements.

     

    Technical Parameters
    Parameter Specification
    Model C002-2
    Type Straight five-port, internal plug-in type
    Cell Material High-borosilicate glass
    Cell Configuration Three-electrode system
    Capacity 10–500 mL
    Custom Capacity Available upon request
    Cell Structure Single-layer / Double-layer
    Cover Material PTFE
    Cover Sizes Approx. 50 / 60 / 70 mm, depending on capacity
    Electrode Installation Internal plug-in through cover
    Electrode Requirement Electrodes must be matched to the cell
    Reference Electrode Ag/AgCl electrode only
    Salt Bridge / Luggin Capillary Not supported
    Atmosphere Control Optional valve and gas inlet/aeration system
    Vacuum Operation Available; below -100 kPa specified
    Pressure Operation Up to 0.6 MPa under applicable configuration and safety conditions
    Temperature Control Double-layer version supports circulating thermostatic water
    Cell Material Options Single-layer or double-layer glass
     

    Applications
    The C002-2 electrochemical cell is suitable for:
    •  Electrochemical and electroanalytical research
    •  Three-electrode electrochemical experiments
    •  Cyclic voltammetry and related electrochemical measurements
    •  Electrocatalysis and electrode material research
    •  Battery and energy-storage material studies
    •  Corrosion and surface electrochemistry
    •  Controlled-atmosphere electrochemical experiments
    •  Temperature-controlled electrolyte testing
    •  Vacuum or pressure-assisted electrochemical research

     

    C002-2 vs. Conventional Open Electrochemical Cell
    Feature C002-2 Sealed Cell Conventional Open Cell
    Sealing Highly sealed Usually open
    Electrode Installation Internal plug-in Usually externally mounted
    Atmosphere Control Supported with valves Limited
    Gas Protection Available More difficult
    Temperature Control Double-layer option Usually external
    Vacuum Operation Supported under specifications Generally unavailable
    Capacity 10–500 mL Varies
    Three-Electrode Research Excellent Available
     

    FAQ
    1. What is the C002-2 electrochemical cell used for?
    It is designed for sealed three-electrode electrochemical experiments, including electroanalysis, electrocatalysis, corrosion research, and electrode material studies.
    2. What is the material of the cell body?
    The cell body is made of high-borosilicate glass, while the cover is made of chemically resistant PTFE.
    3. What capacities are available?
    Standard configurations cover 10 mL to 500 mL. Custom capacities can also be produced according to experimental requirements.
    4. Can the C002-2 maintain an inert atmosphere?
    Yes. With the appropriate valves and gas inlet/aeration components, the sealed cell can be purged with a protective gas.
    5. Can a Luggin capillary or salt bridge be added?
    No. Due to its structural design, the C002-2 cannot accommodate a sand-core salt bridge or Luggin capillary. An Ag/AgCl reference electrode is required.
    6. Does the cell support temperature control?
    Yes. The double-layer version has a jacket through which thermostatic circulating water can flow to maintain the electrolyte at a controlled temperature.
    7.  Can the cell be evacuated or pressurized?
    Vacuum operation is supported according to the specified design. Pressure operation can reach up to 0.6 MPa only under applicable configurations and safety requirements. The double-layer cell should not be pressurized because of its thinner inner glass structure.
    8.  Are the electrodes interchangeable?
    The electrodes must be matched to the C002-2 cell structure to ensure proper installation and sealing.
     
     


  • FAQ
    1. What is the C002-2 electrochemical cell used for?
    It is designed for sealed three-electrode electrochemical experiments, including electroanalysis, electrocatalysis, corrosion research, and electrode material studies.
    2. What is the material of the cell body?
    The cell body is made of high-borosilicate glass, while the cover is made of chemically resistant PTFE.
    3. What capacities are available?
    Standard configurations cover 10 mL to 500 mL. Custom capacities can also be produced according to experimental requirements.
    4. Can the C002-2 maintain an inert atmosphere?
    Yes. With the appropriate valves and gas inlet/aeration components, the sealed cell can be purged with a protective gas.
    5. Can a Luggin capillary or salt bridge be added?
    No. Due to its structural design, the C002-2 cannot accommodate a sand-core salt bridge or Luggin capillary. An Ag/AgCl reference electrode is required.
    6. Does the cell support temperature control?
    Yes. The double-layer version has a jacket through which thermostatic circulating water can flow to maintain the electrolyte at a controlled temperature.
    7.  Can the cell be evacuated or pressurized?
    Vacuum operation is supported according to the specified design. Pressure operation can reach up to 0.6 MPa only under applicable configurations and safety requirements. The double-layer cell should not be pressurized because of its thinner inner glass structure.
    8.  Are the electrodes interchangeable?
    The electrodes must be matched to the C002-2 cell structure to ensure proper installation and sealing.
     

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com