Position: Home > > Environmental monitoring and analysis > Gas on-line monitoring > Flue gas monitoring system > ZR-D13E flue gas measuring instrument

ZR-D13E flue gas measuring instrument

Product ID:HQZXyanqi043

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberZR-D13E
    Brand NameQINGDAOZHONGRUI
    Payment TermsTT,PAYPAL
    ZR-D13E flue gas measuring instrument
     
    Introduction:
    ZR-D13E type resistance-capacitance type flue gas humidity measuring instrument is a device that uses the principle of resistance-capacitance method to measure the humidity of flue gas. It is suitable for complex and harsh measurement environments such as high temperature, high humidity, high dust, high corrosion, and static electricity. It can directly display moisture content, relative humidity, and smoke temperature, and can replace the dry and wet bulb method to measure humidity independently without external power extraction.
    Features:
    1. Using the principle of resistance-capacitance method, imported sensors are used to ensure the accuracy and stability of the measurement, and the response time is fast;
    2. It can be used alone or with other online measuring equipment or hand-held equipment;
    3. Special protection for the measuring probe, which can adapt to the complex and harsh measurement environment such as high temperature, high humidity, high dust, high corrosion, static electricity, etc., to ensure the measurement accuracy and effectively prolong the service life of the measuring probe;
    4. Color touch screen and key double control operation, real-time feedback, double guarantee;
    5. Using 316 stainless steel pipe, the standard effective length is 1m, and the optional extension pipe is suitable for flues of different thicknesses;
    6. The sampling tube is heat traced throughout the process, which can effectively prevent the sensor from condensing;
    7. Optional internal heating function to prevent the pipeline from freezing in extremely cold weather;
    8. The main shell integrated mold design is convenient and fast, and has high reliability.
    9. With storage, query, Bluetooth printing, USB export, RS485 communication functions, optional Bluetooth communication;
    10. With lithium battery, it is convenient to view and print data at any time.
    Technical parameter:
    Sampling tube length: (length 1355 × thickness 75 × width 152) mm, standard effective length 1m
    Working power supply: input AC (220±22)V, (50±1)Hz; output DC24V 10A
    Host weight: about 2.4kg
    Host power consumption: ≤200W
  • Introduction:
    ZR-D13E type resistance-capacitance type flue gas humidity measuring instrument is a device that uses the principle of resistance-capacitance method to measure the humidity of flue gas. It is suitable for complex and harsh measurement environments such as high temperature, high humidity, high dust, high corrosion, and static electricity. It can directly display moisture content, relative humidity, and smoke temperature, and can replace the dry and wet bulb method to measure humidity independently without external power extraction.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com