Position: Home > > Measurement instrument > Other measuring/measurement instrument > Vacuum gauge > ZDK-27 Ionization Vacuum Gauge for High vacuum detection

ZDK-27 Ionization Vacuum Gauge for High vacuum detection

Product ID:CLQTzkj029

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberZDK-27
    Brand NameJININGCHENYANG
    Payment TermsTT,PAYPAL
    ZDK-27 Ionization Vacuum Gauge
     
    Introduction:
    In a low-pressure gas, the number of positive ions generated by the ionization of gas molecules is proportional to the gas pressure. The ionization vacuum gauge is a vacuum measuring instrument based on the principle that the pressure of the gas to be measured is proportional to the ion current generated by gas ionization under certain conditions.
    According to the method of ion generation, the vacuum gauge that uses the hot cathode to emit electrons to ionize the gas is called the hot cathode ionization vacuum gauge; among them, the hot cathode ionization vacuum gauge is composed of a hot cathode gauge tube and a measuring instrument. The measuring instrument is composed of regulating power supply, emission current regulator, ion current measuring amplifier and other parts. The hot cathode ionization gauge is connected to the vacuum system under test. The hot cathode ionization gauge is a triode with a cathode, a grid, and a collector. The collector potential is negative relative to the cathode; the grid is positive relative to the cathode. When the ionization gauge is energized and heated, the cathode emits electrons. When the electrons reach the grid, they collide with gas molecules to produce positive ions and electrons. When the emission current is constant, the number of positive ions is proportional to the pressure of the gas being measured. After the positive ions are collected by the collector and amplified by the measuring circuit, the vacuum degree to be measured can be read by the instruction meter.
    Technical parameter:
    Equipped with regulation: ZJ-27
    Measuring range: 10-1--10-5 Pa
    Number of measurement channels: 1 channel
    Number of control channels: 2 channels
    Control method: point control or area control
    Control range: 10-1-10-5 Pa
    Control accuracy: 1%
    Response time: 1S
    Display mode: LED digital tube 5-digit digital tube, single display
    Relay control capability: AC220V/3A (non-inductive load)
    Power supply: AC220V±10% 50Hz
    Power consumption: 30W
    Weight: 5Kg
    Chassis size: 320X280X88
    Optional function
    1. The cable can be lengthened.
    2.It can be equipped with analog output such as 0-5V/10V, 0/4-10/20 mA.
    3.It can be equipped with RS232 or 485 interface.
    4. The regulation can be equipped with different interface methods.
  • Introduction:
    In a low-pressure gas, the number of positive ions generated by the ionization of gas molecules is proportional to the gas pressure. The ionization vacuum gauge is a vacuum measuring instrument based on the principle that the pressure of the gas to be measured is proportional to the ion current generated by gas ionization under certain conditions.
    According to the method of ion generation, the vacuum gauge that uses the hot cathode to emit electrons to ionize the gas is called the hot cathode ionization vacuum gauge; among them, the hot cathode ionization vacuum gauge is composed of a hot cathode gauge tube and a measuring instrument. The measuring instrument is composed of regulating power supply, emission current regulator, ion current measuring amplifier and other parts. The hot cathode ionization gauge is connected to the vacuum system under test. The hot cathode ionization gauge is a triode with a cathode, a grid, and a collector. The collector potential is negative relative to the cathode; the grid is positive relative to the cathode. When the ionization gauge is energized and heated, the cathode emits electrons. When the electrons reach the grid, they collide with gas molecules to produce positive ions and electrons. When the emission current is constant, the number of positive ions is proportional to the pressure of the gas being measured. After the positive ions are collected by the collector and amplified by the measuring circuit, the vacuum degree to be measured can be read by the instruction meter.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com