    ZD-3A Automatic Potentiometric Titrator
     
    Product Introduction
    The ZD-3A Automatic Potentiometric Titrator is a versatile laboratory instrument designed for potentiometric titration and chemical analysis. It is suitable for applications in environmental monitoring, metallurgy, pharmaceuticals, educational institutions, and research laboratories.
    Combining potentiometric titration with high-precision pH measurement, the instrument supports acid-base titration and various other analytical procedures, including water analysis. Its LED digital display provides clear, direct readings of titration values. Users can select manual operation or preset automatic titration, simplifying routine laboratory workflows.

     


    Performance Features
    • Dual-function measurement: Integrates potentiometric titration and pH measurement.
    •  High-precision pH readings: Provides a pH measurement resolution of 0.01 pH.
    •  Automatic titration control: Supports preset automatic titration for improved operational convenience.
    •   Manual operation: Offers flexibility for different laboratory procedures.
    •   LED digital display: Displays measurement and titration values clearly.
    • Wide application range: Suitable for environmental, pharmaceutical, metallurgical, educational, and research laboratories.

     


    Working Principle
    The ZD-3A Automatic Potentiometric Titrator measures the potential difference between electrodes as a titrant is added to a sample. Changes in electrode potential help identify the titration endpoint, supporting quantitative chemical analysis. In pH measurement mode, the instrument measures the sample's pH using an appropriate electrode. Manual or preset automatic operation allows users to select a suitable titration procedure.

     


    Technical Parameters
    Parameter Specification
    Model ZD-3A
    Potential Measurement Range 0 to ±1999 mV
    pH Measurement Range 0–14.00 pH
    Potential Measurement Accuracy 0.1% F.S.
    pH Measurement Resolution 0.01 pH
    Control Accuracy ±0.03 pH; ±3 mV
    Input Impedance Not specified
    Operating Temperature 5–40°C
    Relative Humidity Below 85%
    Power Supply AC 220 V ±10%, 50 Hz
    Power Consumption 20 W
    Net Weight Approximately 6 kg
    Note: The original specification lists a potential range of 0 to +1999 mV. The bipolar range shown above should be confirmed with the manufacturer before publication.
     


    Application Scenarios
    •   Environmental Laboratories: Acid-base titration and water quality analysis.
    • Pharmaceutical Laboratories: Chemical testing and routine analytical procedures.
    •   Metallurgical Laboratories: Potentiometric analysis of chemical components.
    •   Universities and Research Institutes: Laboratory teaching, experiments, and analytical research.
    • Chemical Laboratories: Quantitative analysis using potentiometric titration methods.

     


    ZD-3A vs. Conventional Manual Titration
    Comparison Item ZD-3A Automatic Potentiometric Titrator Conventional Manual Titration
    Endpoint Detection Based on electrode potential measurement Often relies on visual indicators
    Operation Manual or preset automatic operation Primarily manual
    Result Display Direct LED digital display Often requires manual reading
    pH Measurement Integrated pH measurement function Usually requires separate equipment
    Operating Convenience Simplifies routine titration procedures More operator-dependent
    Typical Applications Laboratory chemical analysis and water testing General-purpose chemical analysis
     


    Frequently Asked Questions
    1. What is the ZD-3A Automatic Potentiometric Titrator used for?
    It is designed for potentiometric titration, pH measurement, acid-base analysis, and other laboratory chemical testing procedures.
    2. Which industries can use the ZD-3A titrator?
    It is suitable for environmental monitoring, pharmaceuticals, metallurgy, chemical laboratories, universities, and research institutions.
    3. What is the pH measurement range?
    The instrument has a pH measurement range of 0–14.00 pH.
    4. What is the potential measurement range?
    The supplied specifications state 0 to +1999 mV. Confirm whether the instrument supports negative potential measurements before ordering.
    5. Does the ZD-3A support automatic titration?
    Yes. It supports manual operation and preset automatic titration, providing flexibility for different analytical requirements.
    6. How are measurement results displayed?
    Titration values are displayed digitally through the instrument's LED display for convenient reading.
    7. What are the operating environment requirements?
    The recommended operating temperature is 5–40°C, with relative humidity below 85%.
    8. What power supply does the instrument require?
    It operates on AC 220 V ±10% at 50 Hz, with a rated power consumption of 20 W.




     
  • Frequently Asked Questions
    1. What is the ZD-3A Automatic Potentiometric Titrator used for?
    It is designed for potentiometric titration, pH measurement, acid-base analysis, and other laboratory chemical testing procedures.
    2. Which industries can use the ZD-3A titrator?
    It is suitable for environmental monitoring, pharmaceuticals, metallurgy, chemical laboratories, universities, and research institutions.
    3. What is the pH measurement range?
    The instrument has a pH measurement range of 0–14.00 pH.
    4. What is the potential measurement range?
    The supplied specifications state 0 to +1999 mV. Confirm whether the instrument supports negative potential measurements before ordering.
    5. Does the ZD-3A support automatic titration?
    Yes. It supports manual operation and preset automatic titration, providing flexibility for different analytical requirements.
    6. How are measurement results displayed?
    Titration values are displayed digitally through the instrument's LED display for convenient reading.
    7. What are the operating environment requirements?
    The recommended operating temperature is 5–40°C, with relative humidity below 85%.
    8. What power supply does the instrument require?
    It operates on AC 220 V ±10% at 50 Hz, with a rated power consumption of 20 W.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com