Position: Home > > Lab general equipment > Cleaning / disinfection equipment > High pressure sterilization > YM30 Vertical Pressure Steam Autoclave

YM30 Vertical Pressure Steam Autoclave

Product ID:SYQXXDmj006

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberYM30
    Brand NameSHSANSHEN
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    YM30 Vertical Pressure Steam Autoclave
     
    Product Introduction
    The YM30 Vertical Pressure Steam Autoclave is designed for medical institutions to sterilize medical instruments and other items that can withstand high-temperature, high-pressure steam. With a 30-liter chamber made of 304 stainless steel, the YM30 combines microcomputer-controlled heating and timing, precise temperature regulation, and multiple safety protection functions.
    Its vertical design, automatic lid-opening assistance, low-water automatic replenishment, and LED operating-status indicators support convenient daily operation. The autoclave uses gravity steam displacement to establish a steam environment inside the chamber and is suitable for routine sterilization workflows in medical settings.
    Intended use: Sterilization of pressure- and high-temperature-steam-resistant medical instruments. Contraindications, operating precautions, and detailed instructions are provided in the product manual.

     


    Performance Features
    1. 304 Stainless Steel Construction: Provides a durable chamber structure suitable for routine sterilization operations.
    2. Convenient Lid Design: Lightweight lid-opening structure with automatic lid lift assistance for easier access.
    3. Angled Control Panel: Designed to improve operator visibility and accessibility.
    4. Pressure Safety Interlock: Prevents the lid from opening while pressure remains inside the chamber.
    5. Microcomputer Program Control: Automatically manages the heating and timing stages of the sterilization process.
    6. LED Status Display: Digital display and indicator lights show equipment operating status.
    7. PID Temperature Control: Self-tuning control adjusts heating parameters to reduce temperature overshoot, with temperature control accuracy within ±0.5°C.
    8. Automatic Low-Water Replenishment: Detects low water levels, activates audible and visual alarms, and resumes heating automatically after water replenishment.
    9.  Gravity Steam Displacement: Uses gravity-based steam exhaust to create a steam environment inside the chamber.
    10. Self-Expanding Silicone Seal: Radially expanding silicone rubber sealing ring helps maintain a reliable chamber seal.
    11. Overtemperature Protection: Automatically stops heating and triggers audible and visual alarms when the temperature exceeds the set value by 2°C.
    12. Automatic Overpressure Relief: A safety valve releases steam when the pressure reaches 0.17 MPa.
    13. Concentrated Water Drainage: A drain valve allows accumulated concentrated water to be discharged from the chamber.
    14.  Mobile Design: Universal casters with brakes support movement and stable positioning.
    15. Immersion Heating: An immersed electric heating element provides chamber heating.

     


    Working Principle
    The YM30 sterilizer uses saturated steam under pressure to sterilize compatible medical instruments. Water is heated by an immersed electric heating element, producing steam that displaces air through a gravity-based exhaust process. The microcomputer controller manages heating and timing according to the selected operating settings.
    PID temperature regulation helps maintain the target temperature and reduce overshoot. Safety systems monitor water level, temperature, and chamber pressure to support controlled operation. The pressure interlock prevents the lid from opening while the chamber remains pressurized, while the safety valve releases steam if the pressure reaches its specified relief threshold.
    Important: Actual sterilization effectiveness depends on the selected cycle, load configuration, steam contact, exposure time, and proper operating procedures. Follow the manufacturer's validated instructions for the intended load.

     


    Technical Parameters
    Parameter Specification
    Model YM30
    Product Type Vertical Pressure Steam Autoclave
    Power Supply AC 220 V, 50 Hz
    Rated Power 3 kW
    Chamber Capacity 30 L
    Water Supply Pressure ≥0.2 to ≤0.3 MPa
    Working Pressure Varies with temperature
    Working Temperature Ambient temperature +5°C to 126°C, selectable
    Holding Time 1–99.59 min/h, as specified by the manufacturer
    Temperature Difference Within Chamber <1°C
    Basket Dimensions Ø38 × 30 cm
    Overall Dimensions 70 × 51 × 73 cm
    Wooden Package Dimensions 78 × 61 × 87 cm
    Gross Weight 85 kg
    Net Weight 70 kg
    Temperature Control Accuracy Within ±0.5°C
    Overtemperature Protection Heating stops and audible/visual alarm activates at 2°C above the set temperature
    Safety Valve Relief Pressure 0.17 MPa
    Note: The holding-time notation “1–99.59 min/h” follows the supplied specifications. Confirm the exact timer format and operating-pressure range with the manufacturer before publication or purchase.
     


    Application Scenarios
    • Hospitals and Clinics: Sterilization of reusable medical instruments compatible with high-temperature, high-pressure steam.
    • Medical Treatment Rooms: Routine sterilization workflows for approved instruments and accessories.
    • Healthcare Facilities: Sterilization support in designated instrument-processing areas.
    • Medical Laboratories: Steam sterilization of compatible equipment and materials where permitted by the instrument's instructions.
    • Central Sterile Supply Departments: Routine sterilization tasks involving suitable, properly prepared loads.
    Only load items that are confirmed by their manufacturers to be compatible with the selected steam sterilization cycle.

     


    YM30 Vertical Autoclave vs. Basic Steam Sterilizers
    Feature YM30 Vertical Pressure Steam Autoclave Basic Steam Sterilizer
    Chamber Material 304 stainless steel Depends on model
    Chamber Capacity 30 L Varies
    Heating and Timing Microcomputer-controlled Depends on model
    Temperature Regulation PID control; accuracy within ±0.5°C Depends on model
    Operating Display LED digital display and indicator lights Depends on model
    Low-Water Protection Automatic replenishment with audible/visual alarm Depends on model
    Pressure Interlock Prevents opening under pressure Depends on model
    Overtemperature Protection Automatic heating cutoff and alarm Depends on model
    Overpressure Protection Safety valve relief at 0.17 MPa Depends on model
    Mobility Lockable universal casters Depends on model
    This is a feature-based comparison, not a comparison with a specific competing model. Actual capabilities vary by manufacturer and configuration.
     


    Frequently Asked Questions
    1. What is the YM30 Vertical Pressure Steam Autoclave used for?
    It is designed for medical institutions to sterilize medical instruments that can withstand high-temperature, high-pressure steam, following the manufacturer's instructions.
    2. What is the chamber capacity of the YM30?
    The YM30 has a nominal chamber capacity of 30 liters.
    3. What is the maximum selectable working temperature?
    The specified working temperature range is from ambient temperature +5°C to 126°C, with the operating temperature selectable by the user.
    4. How accurate is the temperature control?
    The microcomputer controller uses PID regulation and self-tuning to help prevent temperature overshoot. The specified temperature control accuracy is within ±0.5°C.
    5. What safety features does the YM30 include?
    Safety features include a pressure lid interlock, low-water alarm and automatic replenishment, overtemperature heating cutoff, audible and visual alarms, and a pressure safety valve that releases steam at 0.17 MPa.
    6. Can the lid be opened while the chamber is pressurized?
    No. The pressure safety interlock prevents the lid from opening while pressure remains inside the chamber. Follow the operating manual and confirm that pressure has been fully released before opening.
    7. Does the YM30 automatically replenish water?
    Yes. When a low water level is detected, the unit activates audible and visual alarms and supports automatic water replenishment. Heating resumes automatically after replenishment, according to the supplied specifications.
    8. What power supply does the YM30 require?
    It operates on AC 220 V, 50 Hz, with a rated power of 3 kW.
    9. What should users confirm before purchasing?
    Confirm that the 30L capacity, maximum temperature of 126°C, water supply pressure requirements, electrical supply, and sterilization cycle settings meet the intended application. Also verify the validated cycle parameters, maintenance requirements, and applicable local regulatory requirements with the manufacturer.


  • Frequently Asked Questions
    1. What is the YM30 Vertical Pressure Steam Autoclave used for?
    It is designed for medical institutions to sterilize medical instruments that can withstand high-temperature, high-pressure steam, following the manufacturer's instructions.
    2. What is the chamber capacity of the YM30?
    The YM30 has a nominal chamber capacity of 30 liters.
    3. What is the maximum selectable working temperature?
    The specified working temperature range is from ambient temperature +5°C to 126°C, with the operating temperature selectable by the user.
    4. How accurate is the temperature control?
    The microcomputer controller uses PID regulation and self-tuning to help prevent temperature overshoot. The specified temperature control accuracy is within ±0.5°C.
    5. What safety features does the YM30 include?
    Safety features include a pressure lid interlock, low-water alarm and automatic replenishment, overtemperature heating cutoff, audible and visual alarms, and a pressure safety valve that releases steam at 0.17 MPa.
    6. Can the lid be opened while the chamber is pressurized?
    No. The pressure safety interlock prevents the lid from opening while pressure remains inside the chamber. Follow the operating manual and confirm that pressure has been fully released before opening.
    7. Does the YM30 automatically replenish water?
    Yes. When a low water level is detected, the unit activates audible and visual alarms and supports automatic water replenishment. Heating resumes automatically after replenishment, according to the supplied specifications.
    8. What power supply does the YM30 require?
    It operates on AC 220 V, 50 Hz, with a rated power of 3 kW.
    9. What should users confirm before purchasing?
    Confirm that the 30L capacity, maximum temperature of 126°C, water supply pressure requirements, electrical supply, and sterilization cycle settings meet the intended application. Also verify the validated cycle parameters, maintenance requirements, and applicable local regulatory requirements with the manufacturer.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com