Position: Home > > Environmental monitoring and analysis > Airborne particulate matter > Particle counter > Y09-516DS Laser Dust Particle Counter

Y09-516DS Laser Dust Particle Counter

Product ID:HQKLlzjs025

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberY09-516DS
    Brand NameSZHONGJI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    Y09-516DS Laser Dust Particle Counter
     
    Product Introduction
    The Y09-516DS Laser Dust Particle Counter is designed to measure and analyze the size and number of airborne particles per unit volume in clean environments. It helps users evaluate cleanroom cleanliness levels according to selected classification standards.
    With a sampling flow rate of 28.3 L/min and six particle-size channels from 0.5 to 10 μm, this laser particle counter is suitable for cleanroom qualification, environmental monitoring, and routine contamination control. Its touchscreen interface, onboard data storage, USB export, and built-in dot-matrix printer support convenient measurement, reporting, and traceable recordkeeping.
    The instrument is widely applicable in pharmaceutical, medical, optical, chemical, food, cosmetics, electronics, biotechnology, and aerospace manufacturing environments.

     


    Performance Features
    •  Six particle-size channels: Measures particles at 0.5, 1.0, 2.0, 3.0, 5.0, and 10 μm.
    • Stable sampling flow: Provides a sampling flow rate of 28.3 L/min for cleanroom particle monitoring.
    •  Touchscreen operation: Features an 800 × 400 resolution display with 65K colors.
    •  Multiple cleanliness standards: Supports selectable ISO, GMP, and 209E standards.
    • Extensive data storage: Stores measurement records and UCL data for review and reporting.
    •   USB data export: Simplifies transfer of particle-counting results to a computer.
    •   Built-in printer: Enables convenient on-site printing of measurement reports.
    •  Configurable alarms: Allows alarm thresholds to be set for individual channels, including 0.5, 1.0, and 5.0 μm channels.
    • Long-life laser source: Uses a laser diode with a specified mean time to failure (MTTF) of 50,000 hours.
    •Multiple measurement methods: Supports automatic measurement, calculation measurement, and confidence-level measurement.

     


    Working Principle
    The Y09-516DS uses laser light scattering to detect airborne particles. During sampling, air enters the instrument at a controlled flow rate and passes through the optical sensing region. Particles scatter the laser light, and the resulting optical signals are processed to determine particle counts and classify them by size.
    The instrument displays particle concentrations across six size channels and can use the results to assess cleanroom cleanliness against the selected standard. Measurement data can be stored internally, exported via USB, and printed using the built-in printer. Configurable particle-count alarms help users identify when measured levels exceed preset limits.

     


    Technical Parameters
    Parameter Specification
    Model Y09-516DS
    Instrument Type Laser Dust Particle Counter
    Sampling Flow Rate 28.3 L/min
    Particle Size Channels 0.5, 1.0, 2.0, 3.0, 5.0, 10 μm
    Dimensions (W × D × H) 285 × 240 × 240 mm
    Weight 7.35 kg
    Sampling Period Adjustable from 1 second to 99 minutes 99 seconds
    Sampling Interval 1 hour to 99 hours, 99 minutes, 99 seconds
    Power Supply 14.8 V lithium battery
    Rated Power 30 W
    Display Touchscreen, 800 × 400 resolution, 65K colors
    Self-Cleaning Time ≤10 minutes
    Laser Source Life 50,000-hour MTTF
    Printing Method Built-in dot-matrix printer
    Alarm Settings Configurable thresholds for 0.5, 1.0, and 5.0 μm channels
    Data Storage 10,000 measurement records + 3,000 UCL records
    Continuous Operating Time Approx. 6 hours
    Maximum Sampling Concentration 35,000 particles/L
    Operating Temperature 10–35°C
    Operating Humidity 20%–75% RH
    Data Export USB
    Supported Standards Selectable ISO, GMP, and 209E standards
    Report Standards Listed GMP, ISO 14644, 209E, ISO 21501-4
    Measurement Methods Automatic measurement, calculation measurement, confidence-level measurement
    Optional Accessory SS auxiliary trolley
     


    Application Scenarios
    •  Pharmaceutical cleanrooms: Monitor airborne particles in production areas and controlled environments.
    • Medical and healthcare facilities: Support cleanliness assessment in controlled workspaces.
    • Electronics manufacturing: Monitor airborne contamination in sensitive assembly and production areas.
    •  Optical manufacturing: Evaluate particle levels where dust can affect optical components and product quality.
    •  Food and cosmetics production: Support environmental hygiene monitoring in clean production areas.
    • Biotechnology laboratories: Monitor airborne particulate contamination in controlled laboratory environments.
    • Aerospace manufacturing: Support particle monitoring in precision manufacturing and assembly facilities.
    •  Cleanroom certification and routine checks: Collect particle-counting data for cleanliness assessment and documentation.

     


    Comparison: Y09-516DS vs. Basic Airborne Particle Counters
    Feature Y09-516DS Laser Particle Counter Basic Particle Counter
    Particle Size Channels Six channels, 0.5–10 μm Depends on model
    Sampling Flow Rate 28.3 L/min Depends on model
    User Interface Color touchscreen May use buttons or a simpler display
    Data Storage 10,000 measurement records + 3,000 UCL records Depends on model
    Data Export USB May be limited or unavailable
    Report Printing Built-in dot-matrix printer May require an external printer
    Alarm Configuration Configurable channel thresholds Depends on model
    Cleanliness Standards Selectable ISO, GMP, and 209E Depends on model
    Typical Applications Cleanroom monitoring and documented testing General particle-counting tasks
     


    Frequently Asked Questions (FAQ)
    Q1: What is the Y09-516DS laser particle counter used for?
    It measures airborne particle sizes and concentrations to help assess cleanliness levels in cleanrooms and other controlled environments.
    Q2: What particle sizes can it detect?
    The instrument has six channels: 0.5, 1.0, 2.0, 3.0, 5.0, and 10 μm.
    Q3: What is its sampling flow rate?
    The specified sampling flow rate is 28.3 L/min.
    Q4: Which cleanliness standards does it support?
    The instrument offers selectable ISO, GMP, and 209E standards. Its listed reporting standards include ISO 14644 and ISO 21501-4. Users should confirm the applicable configuration and reporting requirements before compliance testing.
    Q5: Can measurement data be exported to a computer?
    Yes. The instrument supports USB data export and internal storage for measurement records and UCL data.
    Q6: Does it support on-site report printing?
    Yes. A built-in dot-matrix printer enables direct printing of measurement results.
    Q7: How long can it operate continuously?
    The specified continuous operating time is approximately 6 hours per charge.
    Q8: Can users configure particle-count alarms?
    Yes. Alarm thresholds can be set for individual channels, including the 0.5, 1.0, and 5.0 μm channels.
    Q9: What environments are suitable for this particle counter?
    It is suitable for controlled environments in pharmaceutical, medical, optical, chemical, food, cosmetics, electronics, biotechnology, and aerospace industries, within its specified operating temperature and humidity ranges.


  • Frequently Asked Questions (FAQ)
    Q1: What is the Y09-516DS laser particle counter used for?
    It measures airborne particle sizes and concentrations to help assess cleanliness levels in cleanrooms and other controlled environments.
    Q2: What particle sizes can it detect?
    The instrument has six channels: 0.5, 1.0, 2.0, 3.0, 5.0, and 10 μm.
    Q3: What is its sampling flow rate?
    The specified sampling flow rate is 28.3 L/min.
    Q4: Which cleanliness standards does it support?
    The instrument offers selectable ISO, GMP, and 209E standards. Its listed reporting standards include ISO 14644 and ISO 21501-4. Users should confirm the applicable configuration and reporting requirements before compliance testing.
    Q5: Can measurement data be exported to a computer?
    Yes. The instrument supports USB data export and internal storage for measurement records and UCL data.
    Q6: Does it support on-site report printing?
    Yes. A built-in dot-matrix printer enables direct printing of measurement results.
    Q7: How long can it operate continuously?
    The specified continuous operating time is approximately 6 hours per charge.
    Q8: Can users configure particle-count alarms?
    Yes. Alarm thresholds can be set for individual channels, including the 0.5, 1.0, and 5.0 μm channels.
    Q9: What environments are suitable for this particle counter?
    It is suitable for controlled environments in pharmaceutical, medical, optical, chemical, food, cosmetics, electronics, biotechnology, and aerospace industries, within its specified operating temperature and humidity ranges.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com