Position: Home > > Environmental monitoring and analysis > Airborne particulate matter > Particle counter > Y09-310 Portable Laser Particle Counter

Y09-310 Portable Laser Particle Counter

Product ID:HQKLlzjs 003

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberY09-310
    Brand NameSUJING
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    Y09-310 Portable Laser Particle Counter
     
    Product Introduction
    The Y09-310 Portable Laser Particle Counter is designed for measuring airborne particle concentrations in cleanrooms and controlled environments. Using a laser diode as its light source, the instrument simultaneously measures particles across six size channels: 0.3, 0.5, 1, 3, 5, and 10 μm.
    Equipped with an imported high-flow sampling pump, LCD display, and built-in thermal printer, the Y09-310 provides convenient particle monitoring and on-site result reporting. It can store up to 1,000 sample records, while dedicated PC software allows users to view measurement data and export files to Excel.
    The instrument is suitable for cleanroom monitoring in microelectronics, precision machinery, optics, pharmaceuticals, sanitation, biotechnology, food and beverage production, and aerospace industries.

     


    Performance Features
    1. Six-Channel Particle Measurement: Simultaneously measures airborne particles at 0.3, 0.5, 1, 3, 5, and 10 μm.
    2.  Laser Diode Light Source: Provides stable optical particle detection, with a specified mean time between failures of 30,000 hours.
    3. High-Flow Sampling Pump: Uses an imported pump with a sampling flow rate of 28.3 L/min.
    4. LCD Display: Displays particle concentration in particles/m³ for convenient on-site monitoring.
    5. Built-In Thermal Printer: Prints particle counting results directly from the instrument.
    6.  Data Storage: Stores up to 1,000 sample records for measurement review.
    7. PC Data Management: Optional dedicated software supports data viewing and Excel file export.
    8. Cleanroom Classification Monitoring: Designed for particle monitoring in environments ranging from Class 10 to Class 300,000, according to the supplied product description.
    9. Alarm Settings: Provides alarm settings for Class 10, Class 100, and Class 1,000 environments.
    10.Portable Design: Compact dimensions and an approximately 8-hour operating time support routine on-site measurements.

     


    Working Principle
    The Y09-310 uses the laser light-scattering principle to detect airborne particles. During sampling, its built-in pump draws a controlled volume of air into the optical sensing chamber.
    When particles pass through the laser beam, they scatter light. The optical detection system collects the scattered light signals and processes them to determine particle counts across the instrument's six predefined size channels.
    The instrument displays particle concentration in particles per cubic meter (particles/m³), stores measurement records, and can print results using its built-in thermal printer. With optional PC software, users can further review and export measurement data.

     


    Technical Parameters
    Parameter Specification
    Model Y09-310
    Instrument Type Portable laser particle counter
    Measurement Channels 0.3, 0.5, 1, 3, 5, 10 μm
    Display LCD
    Particle Concentration Display particles/m³
    Sampling Flow Rate 28.3 L/min (imported pump)
    Sample Time 1 minute (selectable)
    Zero Count ≤20 min
    Light Source Laser diode
    Light Source MTBF 30,000 hours
    Maximum Rated Particle Concentration 35,000 particles/L (for particles ≤0.5 μm)
    Cleanroom Measurement Range Class 10 to Class 300,000 (as specified in the product description)
    Alarm Settings Class 10, Class 100, Class 1,000
    Data Storage 1,000 samples
    Printer Built-in thermal printer
    Operating Time 8 hours
    PC Software Optional dedicated software
    External Dimensions (W × D × H) 300 × 380 × 126 mm
    Weight 10 kg
    Maximum Power Consumption 60 W
    Power Supply AC 220 V ±10%, 50 Hz
    Operating Temperature 10–30°C
    Operating Humidity 20–75% RH
    Atmospheric Pressure 86–106 kPa
     


    Application Scenarios
    The Y09-310 portable laser particle counter is suitable for airborne particle monitoring and cleanroom quality control in:
    • Microelectronics Manufacturing: Monitoring airborne particles in semiconductor and electronic component production areas.
    •  Pharmaceutical Industry: Checking particle contamination in pharmaceutical cleanrooms and controlled production environments.
    •  Precision Machinery: Monitoring environmental cleanliness during precision manufacturing and assembly.
    • Optical Manufacturing: Assessing airborne particle levels in optical component production facilities.
    • Biotechnology and Laboratories: Monitoring particulate contamination in controlled laboratory environments.
    •  Food and Beverage Production: Checking airborne cleanliness in controlled processing and packaging areas.
    • Aerospace Manufacturing: Supporting environmental particle monitoring in precision assembly facilities.
    • Sanitation and Cleanroom Inspection: Conducting routine particle concentration measurements and cleanliness assessments.

     


    Comparison: Y09-310 vs. Basic Particle Monitoring Instruments
    Feature Y09-310 Basic Particle Monitoring Instruments
    Detection Principle Laser light scattering Depends on instrument
    Particle Size Channels Six simultaneous channels Channel configuration varies
    Sampling Flow Rate 28.3 L/min Depends on model
    Display LCD Display configuration varies
    Data Storage 1,000 sample records Depends on model
    On-Site Printing Built-in thermal printer May require an external printer
    PC Data Export Optional software with Excel export Software capability varies
    Portability Portable design; approximately 8-hour operating time Depends on model
     


    Frequently Asked Questions
    1. What is the Y09-310 portable laser particle counter used for?
    It is used to measure airborne particle concentrations in cleanrooms and controlled environments, helping assess environmental cleanliness in manufacturing and laboratory facilities.
    2. Which particle sizes can the Y09-310 measure?
    It simultaneously measures six particle size channels: 0.3, 0.5, 1, 3, 5, and 10 μm.
    3. What is the sampling flow rate?
    The instrument uses an imported high-flow pump with a sampling flow rate of 28.3 L/min.
    4. How are particle concentration results displayed?
    Particle concentration is displayed on the LCD in particles per cubic meter (particles/m³).
    5. Can the Y09-310 print measurement results?
    Yes. It includes a built-in thermal printer for direct printing of particle counting results.
    6. How many measurement records can the instrument store?
    The instrument can store up to 1,000 sample records.
    7. Can measurement data be exported to a computer?
    Yes. Optional dedicated PC software allows users to view measurement records and export data to Excel files.
    8. What is the operating time of the Y09-310?
    The specified operating time is approximately 8 hours.
    9. What is the maximum rated particle concentration?
    The specified maximum rated concentration is 35,000 particles/L for particles ≤0.5 μm.

     
     
     
     
  • Frequently Asked Questions
    1. What is the Y09-310 portable laser particle counter used for?
    It is used to measure airborne particle concentrations in cleanrooms and controlled environments, helping assess environmental cleanliness in manufacturing and laboratory facilities.
    2. Which particle sizes can the Y09-310 measure?
    It simultaneously measures six particle size channels: 0.3, 0.5, 1, 3, 5, and 10 μm.
    3. What is the sampling flow rate?
    The instrument uses an imported high-flow pump with a sampling flow rate of 28.3 L/min.
    4. How are particle concentration results displayed?
    Particle concentration is displayed on the LCD in particles per cubic meter (particles/m³).
    5. Can the Y09-310 print measurement results?
    Yes. It includes a built-in thermal printer for direct printing of particle counting results.
    6. How many measurement records can the instrument store?
    The instrument can store up to 1,000 sample records.
    7. Can measurement data be exported to a computer?
    Yes. Optional dedicated PC software allows users to view measurement records and export data to Excel files.
    8. What is the operating time of the Y09-310?
    The specified operating time is approximately 8 hours.
    9. What is the maximum rated particle concentration?
    The specified maximum rated concentration is 35,000 particles/L for particles ≤0.5 μm.


     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com