Position: Home > > Environmental monitoring and analysis > Airborne particulate matter > Particle counter > Y09-5106DS Laser Dust Particle Counter

Y09-5106DS Laser Dust Particle Counter

Product ID:HQKLlzjs026

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberY09-1016
    Brand NameSZHONHJI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    Y09-5106DS Laser Dust Particle Counter
    Product Introduction
    The Y09-5106DS Laser Dust Particle Counter is a professional cleanroom airborne particle monitoring instrument designed to measure and analyze the size and quantity of dust particles in unit volume air. Based on particle concentration data, the instrument evaluates clean environment cleanliness levels according to relevant cleanliness standards.
    Using advanced laser detection technology, the Y09-5106DS provides accurate particle counting performance with a high flow sampling system, touchscreen operation, long-life laser source, and large-capacity data storage.
    The instrument is widely used for cleanliness inspection and environmental monitoring in pharmaceutical, medical, optical, chemical, food, cosmetics, electronics, biotechnology, and aerospace industries.

     

    Performance Features
    •  High-precision laser particle detection
    Uses laser scattering technology to accurately measure airborne particle size and quantity.
    •  Six particle size channels
    Supports simultaneous detection of 0.5μm, 1.0μm, 2.0μm, 3.0μm, 5.0μm, and 10μm particles.
    •  High sampling flow rate
    100L/min large flow sampling improves detection efficiency and measurement reliability.
    •  Touchscreen operation system
    Equipped with an 800×480 high-resolution color touchscreen for simple operation.
    •  Large data storage capacity
    Stores up to 13,000 pages of test data for convenient traceability and analysis.
    •  Multiple sampling modes
    Supports single, repeat, continuous measurement, and GB model (UCL) calculation methods.
    •  Long-life laser source
    Uses a laser diode with 50,000-hour MTTF for stable long-term operation.
    •  Built-in thermal printer
    Provides direct printing of measurement results.
    •  Adjustable alarm settings
    Particle count alarm thresholds can be independently configured for different channels.
    •  Portable design
    Compact structure with lithium battery power supply, suitable for on-site cleanroom testing.

     

    Working Principle
    The Y09-5106DS laser particle counter works based on the laser light scattering principle.
    The detection process includes:
    1.  Air samples are drawn into the instrument through the sampling inlet.
    2.  Particles in the airflow pass through the laser detection chamber.
    3.  The laser beam illuminates airborne particles.
    4.  Particles scatter light according to their size and concentration.
    5. The optical sensor detects scattered signals and converts them into electrical signals.
    6.  The built-in processor calculates particle size distribution and quantity.
    7.  The system displays, stores, and prints the measurement results.
    This method enables fast and accurate evaluation of cleanroom air cleanliness levels.

     

    Technical Parameters
    Parameter Specification
    Model Y09-5106DS
    Instrument Type Laser Dust Particle Counter
    Brand Hongji Clean
    Detection Principle Laser Light Scattering
    Sampling Flow Rate 100 L/min
    Particle Size Channels 0.5, 1.0, 2.0, 3.0, 5.0, 10 μm
    Sampling Period 1s–99min99s adjustable
    Sampling Frequency 1–99s
    Measurement Methods Single, repeat, continuous, GB model (UCL) calculation
    Display 800×480 resolution, 65K color touchscreen
    Data Storage 13,000 pages
    Printer Built-in dot matrix printer
    Alarm Channels 0.5μm, 1.0μm, 5.0μm channels with adjustable limits
    Laser Source Long-life laser diode, MTTF ≥50,000 hours
    Power Supply 22.2V lithium battery
    Rated Power 90W
    Self-Cleaning Time ≤10 min
    Dimensions 310 × 240 × 280 mm (W×H×D)
    Weight 8.5 kg
    Operating Temperature 10–35℃
    Operating Humidity 20–75% RH
    Optional Accessory SS auxiliary cart
     

    Application Scenarios
    1. Pharmaceutical Cleanrooms
    Used for:
    •  GMP cleanroom certification
    •  Sterile production areas
    •  Pharmaceutical manufacturing environments
    2. Medical and Healthcare Facilities
    Suitable for:
    •  Hospital clean areas
    •  Laboratory environments
    •  Biosafety monitoring
    3. Electronics Industry
    Applied in:
    •  Semiconductor manufacturing
    •  Precision electronic assembly
    •  Dust-controlled workshops
    4. Food and Cosmetics Production
    Used for hygiene monitoring and cleanliness control in production environments.
    5. Aerospace and Optical Industry
    Provides reliable airborne particle measurement for high-precision manufacturing areas.
    6. Research Laboratories
    Suitable for environmental cleanliness evaluation and scientific research applications.

     

    Y09-5106DS Laser Particle Counter vs Traditional Particle Measurement Instruments
    Feature Y09-5106DS Laser Particle Counter Traditional Particle Counter
    Detection Technology Laser scattering method Conventional optical detection
    Sampling Flow 100L/min Usually lower flow rate
    Particle Channels Six size channels Limited channels
    Operation Interface Color touchscreen Basic display/buttons
    Data Storage 13,000 pages Smaller storage capacity
    Printing Function Built-in printer Often requires external printer
    Battery Operation Lithium battery powered Usually fixed power supply
    Application Flexibility Portable cleanroom testing Mainly fixed-site testing
     

    FAQ
    Q1: What is the Y09-5106DS laser particle counter used for?
    The Y09-5106DS is used to measure airborne dust particle size and concentration for cleanroom cleanliness evaluation.
    Q2: What particle sizes can Y09-5106DS detect?
    It detects six particle sizes: 0.5μm, 1.0μm, 2.0μm, 3.0μm, 5.0μm, and 10μm.
    Q3: What industries use the Y09-5106DS particle counter?
    It is widely used in pharmaceutical, medical, electronics, food, cosmetics, chemical, optical, biotechnology, and aerospace industries.
    Q4: What is the sampling flow rate of this particle counter?
    The instrument provides a high sampling flow rate of 100L/min.
    Q5: Does Y09-5106DS support data storage?
    Yes. It can store up to 13,000 pages of measurement records.
    Q6: Can the measurement results be printed?
    Yes. The instrument has a built-in dot matrix printer for direct result printing.
    Q7: How long is the laser source service life?
    The laser diode has a long service life with an MTTF of approximately 50,000 hours.
    Q8: Can Y09-5106DS be used for GMP cleanroom testing?
    Yes. It is suitable for cleanroom monitoring and cleanliness verification in GMP pharmaceutical environments.

     

    Product Summary
    The Y09-5106DS Laser Dust Particle Counter is a high-performance cleanroom airborne particle monitoring system combining laser scattering technology, high-flow sampling, touchscreen operation, and intelligent data management. With accurate particle measurement, portable design, and reliable performance, it is an ideal solution for pharmaceutical cleanrooms, laboratories, electronics manufacturing, food production, and industrial cleanliness monitoring applications.

     
     

     
     
     
  • FAQ
    Q1: What is the Y09-5106DS laser particle counter used for?
    The Y09-5106DS is used to measure airborne dust particle size and concentration for cleanroom cleanliness evaluation.
    Q2: What particle sizes can Y09-5106DS detect?
    It detects six particle sizes: 0.5μm, 1.0μm, 2.0μm, 3.0μm, 5.0μm, and 10μm.
    Q3: What industries use the Y09-5106DS particle counter?
    It is widely used in pharmaceutical, medical, electronics, food, cosmetics, chemical, optical, biotechnology, and aerospace industries.
    Q4: What is the sampling flow rate of this particle counter?
    The instrument provides a high sampling flow rate of 100L/min.
    Q5: Does Y09-5106DS support data storage?
    Yes. It can store up to 13,000 pages of measurement records.
    Q6: Can the measurement results be printed?
    Yes. The instrument has a built-in dot matrix printer for direct result printing.
    Q7: How long is the laser source service life?
    The laser diode has a long service life with an MTTF of approximately 50,000 hours.
    Q8: Can Y09-5106DS be used for GMP cleanroom testing?
    Yes. It is suitable for cleanroom monitoring and cleanliness verification in GMP pharmaceutical environments.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com