Position: Home > > Environmental monitoring and analysis > Airborne particulate matter > Particle counter > Y09-3056DS Laser Dust Particle Counter

Y09-3056DS Laser Dust Particle Counter

Product ID:HQKLlzjs027

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberY09-3056DS
    Brand NameSUZHOUHONGJI
    Payment TermsT/T, paypal,Alibaba.com Pay
     Y09-3056DS Laser Dust Particle Counter
     
    Product Introduction
    The Y09-3056DS Laser Dust Particle Counter is designed to measure and analyze the size and number of airborne particles per unit volume of air in clean environments. The measured particle concentration can be used to evaluate and determine the cleanliness level of controlled environments according to applicable cleanroom standards.
    With a high 50 L/min sampling flow rate and six particle-size channels from 0.3 μm to 10 μm, the Y09-3056DS provides efficient cleanroom particle monitoring. Its 800 × 480 touchscreen display, built-in printer and large data storage capacity make it convenient for routine testing, recording and reporting.
    The laser particle counter is widely used for clean-environment inspection in pharmaceutical, medical, optical, chemical, food, cosmetics, electronics, biological products, aerospace and other industries.

     


    Performance Features
    •  50 L/min high-flow sampling for efficient cleanroom particle measurement.
    •  Six particle-size channels: 0.3, 0.5, 1.0, 2.0, 5.0 and 10 μm.
    •  Measures airborne particle size and concentration in clean environments.
    •  High-resolution 800 × 480 touchscreen control system.
    •  65K-color display for clear measurement information.
    •  Adjustable sampling period from 1s to 99min 99s.
    •  Adjustable sampling frequency from 1s to 99s.
    •  Built-in long-life laser diode with 50,000-hour MTTF.
    •  Automatic self-cleaning time of ≤10 minutes.
    •  Built-in dot-matrix printer for convenient on-site reporting.
    •  Stores up to 13,000 pages of data.
    •  Supports single, repeated and continuous measurement modes.
    •  Supports GB model (UCL) calculation.
    •  Built-in 22.2V lithium battery for portable operation.
    •  Optional SS auxiliary cart for easier transportation and sampling.

     


    Working Principle
    The Y09-3056DS uses the laser light-scattering principle to detect airborne particles.
    During measurement, a controlled volume of air is drawn into the instrument at a sampling flow rate of 50 L/min. When particles pass through the laser detection zone, they scatter the incident laser light. The intensity and characteristics of the scattered light are detected and processed by the instrument's optical and electronic system.
    Based on the detected scattering signals, the instrument determines the corresponding particle-size channel and particle count. The results are displayed on the touchscreen and can be stored internally or printed using the built-in printer.
    The measured particle concentration can then be used for cleanroom cleanliness evaluation and environmental monitoring.

     


    Technical Specifications
    Parameter Specification
    Model Y09-3056DS
    Instrument Type Laser Dust Particle Counter
    Sampling Flow Rate 50 L/min
    Particle Size Channels 0.3, 0.5, 1.0, 2.0, 5.0, 10 μm
    Dimensions 310 × 240 × 280 mm (W × D × H)
    Weight 8.5 kg
    Sampling Period 1s–99min 99s, adjustable
    Sampling Frequency 1–99s
    Power Supply 22.2V lithium battery
    Display 800 × 480 resolution, 65K colors
    Control Touchscreen
    Rated Power 90W
    Self-Cleaning Time ≤10 min
    Light Source Long-life laser diode
    Laser Diode Life 50,000 hours MTTF
    Printer Built-in dot-matrix printer
    Alarm Channels 0.5, 1.0 and 5.0 μm channels; alarm values individually adjustable
    Data Storage 13,000 pages
    Operating Temperature 10–35°C
    Operating Humidity 20–75% RH
    Measurement Modes Single, repeated, continuous
    Calculation Method GB model (UCL)
    Optional Accessory SS auxiliary cart
     


    Application Scenarios
    The Y09-3056DS cleanroom particle counter is suitable for airborne particle monitoring and cleanliness testing in:
    •  Pharmaceutical manufacturing
    •  Medical and healthcare facilities
    •  Cleanrooms and controlled environments
    •  Optical manufacturing
    •  Chemical production
    •  Food processing
    •  Cosmetics manufacturing
    •  Electronics and semiconductor facilities
    •  Biological product manufacturing
    •  Aerospace industry
    •  Laboratory clean environments
    •  Cleanroom certification and routine monitoring
    It is particularly suitable for applications requiring reliable measurement of 0.3–10 μm airborne particles and convenient on-site data recording.

     


    Y09-3056DS vs. Conventional Particle Counter
    Feature Y09-3056DS Laser Particle Counter Conventional Low-Flow Particle Counter
    Sampling flow 50 L/min Typically lower
    Particle channels 6 channels Depends on model
    Particle-size range 0.3–10 μm Depends on model
    Display 800 × 480 touchscreen Depends on model
    Data storage 13,000 pages Usually more limited
    Printer Built-in Depends on model
    Sampling modes Single / repeated / continuous Depends on model
    Alarm settings Individual channel settings Depends on model
    Calculation GB model (UCL) Depends on software
    Battery 22.2V lithium battery Depends on model
    Optional cart Available Not always available
     


    Frequently Asked Questions (FAQ)
    1. What is the Y09-3056DS used for?
    The Y09-3056DS is used to measure airborne particle size and concentration in cleanrooms and other controlled environments for cleanliness monitoring.
    2. What particle sizes can it detect?
    The instrument provides six particle-size channels: 0.3, 0.5, 1.0, 2.0, 5.0 and 10 μm.
    3. What is the sampling flow rate?
    The Y09-3056DS has a 50 L/min sampling flow rate, allowing efficient cleanroom particle sampling.
    4. Can the instrument store measurement data?
    Yes. It can store up to 13,000 pages of data, and the built-in printer can be used for on-site record keeping.
    5. Does the particle counter have an alarm function?
    Yes. Alarm values can be individually configured for the 0.5, 1.0 and 5.0 μm channels.
    6. How long does one sampling cycle last?
    The sampling period can be adjusted from 1 second to 99 minutes 99 seconds, depending on the measurement requirements.
    7. Does it support continuous monitoring?
    Yes. The Y09-3056DS supports single, repeated and continuous measurement modes.
    8. What industries use the Y09-3056DS?
    It is suitable for pharmaceutical, medical, optical, chemical, food, cosmetics, electronics, biological products, aerospace and other clean-environment applications.
    9. Is the laser light source designed for long-term operation?
    Yes. The instrument uses a long-life laser diode with an indicated 50,000-hour MTTF.


  • Frequently Asked Questions (FAQ)
    1. What is the Y09-3056DS used for?
    The Y09-3056DS is used to measure airborne particle size and concentration in cleanrooms and other controlled environments for cleanliness monitoring.
    2. What particle sizes can it detect?
    The instrument provides six particle-size channels: 0.3, 0.5, 1.0, 2.0, 5.0 and 10 μm.
    3. What is the sampling flow rate?
    The Y09-3056DS has a 50 L/min sampling flow rate, allowing efficient cleanroom particle sampling.
    4. Can the instrument store measurement data?
    Yes. It can store up to 13,000 pages of data, and the built-in printer can be used for on-site record keeping.
    5. Does the particle counter have an alarm function?
    Yes. Alarm values can be individually configured for the 0.5, 1.0 and 5.0 μm channels.
    6. How long does one sampling cycle last?
    The sampling period can be adjusted from 1 second to 99 minutes 99 seconds, depending on the measurement requirements.
    7. Does it support continuous monitoring?
    Yes. The Y09-3056DS supports single, repeated and continuous measurement modes.
    8. What industries use the Y09-3056DS?
    It is suitable for pharmaceutical, medical, optical, chemical, food, cosmetics, electronics, biological products, aerospace and other clean-environment applications.
    9. Is the laser light source designed for long-term operation?
    Yes. The instrument uses a long-life laser diode with an indicated 50,000-hour MTTF.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com