Position: Home > > Physical property test > Rheometer/viscometer > rheometer > TY - 6002 without rotor rheometer for Rubber testing

TY - 6002 without rotor rheometer for Rubber testing

Product ID:WLNlb006

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberTY - 6002
    Brand NameYM
    Payment TermsT/T, paypal
    Brief introduction:
    A. high precision sensors: 0 ~ 20 n. m. Resolution: 0.001 N.m.
    B. control system: adopting computer control and interface board for data collection, preservation, processing and printing test results and curve processing.
    C. rotation system: adopting step Electronics control motor + amplitude regulator. Swing Angle: ±0.5o  ±1.
    D. the temperature control system: adopting Inteligent digital temperature control instrument, Automatism adjust PID control parameters in real time.
    Temperature control range of 0-200 ℃, the temperature control precision of plus or minus 0.3 ℃, the temperature resolution 0.1 ℃ or less.
    E. data transmission mode, RS232 transmission
    F. display mode: Vulcanize - 105 + Windows XP test software, according to the computer screen with excellent user software and advanced hardware equipment makes the whole measurement is very convenient, fast, accurate, and pleasant.
    G. cavity: Cr6wv material, in line with the GB/T16584-1996 standard requirement.
    F. measuring way: humanistic way of measurement and control, mouse click the box or host panel light touch button two test modes
    2 , the software function is introduced
    A. standardized test: in accordance with GB/T16584 "rubber - no rotor rheometer is used to test characteristics of sulfide, ISO6502:1991 and ASTMD5289-95.
    B. try to taste data: set the number of rubber, such as "tues 5", "RBS6" and so on. Header name will be added to users such as instructions to print drawings, can be set to any form of title text.
    C. high quality function declaration: the excellent function of humanized design is in the process of testing can modify the measuring time, rubber vulcanization for 20 minutes to complete, set 20 minutes measuring time, real do 11 minutes found nine points, 10 are already completed sulfide, has been down there is no need to do at this moment, only the modified measure time under 20 is divided into 9 or 10 points, press "send", the experiment immediately stop on 9 or 10 points, draw the full vulcanization curve, calculated all the data. If experiments do 18 points, 19 minutes to the end of the vulcanization curve is still to rise, sulfide has yet to be completed, the experiment must do down again, otherwise the data is wrong. At this time to modify the measuring time for 25 points or more, keep experiment, until the sulfide is finished. This function is greatly convenient for the user, save the precious time and rubber.
    D. graph Scale automatic optimization (Auto Scale), after completion of measurement, the software will according to the numerical size measurement 0-5 Mv 0-10 Mv 0-20 Mv automatically adjust Y Scale, make the curve more beautiful, more curve contrast, completely different rubber, the curve of the different shape, different measurement time, yi ke is compared.
    E. database: software preset a database of 100 number. Each library can be deposited in the infinite set of measurement data .In the face of a few months a few years decades tens of thousands of sets of data query is convenient in the future, the user can put data in different periods in different database, set the address this is the purpose of the database.
    F. automatic archive end of the test, the test is automatically calculate t10, t30, t-50, t70, t90, ts1, ts2,'s Vc1 and Vc2, minimum torque, maximum torque, etc.
    3 , the attachment
    A. one year warranty and A Chinese operating instructions.
    B. a rheometer special test software.
    C. a brand computer (19 'liquid crystal display), color ink jet printer.
    4 , the main count index
    A. temperature measuring range: 0 ℃ to 200 ℃
    B. temperature measuring accuracy: ≤ ±0.3℃
    C. temperature control precision: ≤ ±0.3℃
    D. the temperature resolution: 0.1 ℃
    E. torque range: 0-10 n. m 0-20 n. M
    F. moment resolution: 0.001 N.m
    G. cavity frequency: 1.7 Hz
    H. amplitude: ±0.5  ±1
    I. the environment temperature: 0 to 35 ℃ relative humidity < 80%
    J. vulcanization time setting range: min. 2-300
    K. distribution 0.5 MPa
    L. power  AC220 v 800w
    M. the machine size: 660 * 580 * 580 mm
    N. The machine weight: about 210 kg

     
     
  • Brief introduction:
    A. high precision sensors: 0 ~ 20 n. m. Resolution: 0.001 N.m.
    B. control system: adopting computer control and interface board for data collection, preservation, processing and printing test results and curve processing.
    C. rotation system: adopting step Electronics control motor + amplitude regulator. Swing Angle: ±0.5o  ±1.


     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com