Position: Home > > Analytical instruments > Element analyzer > Sulfur nitrogen analyzer > TS6100 UV fluorescence sulfur analyzer

TS6100 UV fluorescence sulfur analyzer

Product ID:FYld011

Price: US$30,000.00 ~ US$80,000.00 PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberTS6100
    Brand NameYIMA
    Payment TermsT/T, paypal
    TS6100 UV fluorescence sulfur analyzer
    Introduction:
    TS6110 is Nordisk Tyco UV fluorescence total sulfur analyzer, which is also the second generation models.
    With three domestic initiative, automatic liquid injector, catalytic combustion technology, you can use the air as carrier gas and gas. Once introduced to the market, get a good market response.
    Features:
    1 catalytic combustion technology
    Catalytic combustion technology, making the sample can be completely converted to avoid carbon deposition
    2 Use synthetic air as carrier gas and combustion gas
    Currently available on the market UV fluorescence sulfur analyzer uses Ar as a carrier gas, oxygen as aiding gas. TS6100 series of UV fluorescence sulfur analyzer innovative use of synthetic air as a carrier gas and combustion, to avoid gas problems in remote areas, effectively reducing the maintenance costs of the instrument.
    3 Liquid Autosampler
    The use of volume difference injection method: can effectively avoid the interference of air bubbles
    High and low sample analysis: In the same batch of sample analysis can be used for different samples of different injection volume
    Two sections of standard curve: low concentration curve for low content samples, making the measurement of low content samples more accurate
    Technical Parameters:
    Meet the standards: SH / T0689-2000; ASTM D5453
    Required gas: Synthetic air (replaceable with air generator)
    Gas flow rate: flow rate range 350-450mgl / min (input pressure ≤ 0.12Mpa)
    Injection mode: manual injection or automatic liquid autosampler
    Furnace temperature: up to 1200 ℃
    Temperature control accuracy: ± 1% FS
    Burning tube: Catalyst filled quartz reaction tube
    Water removal mode: maintenance-free membrane dryer
    Detector: High sensitivity UV fluorescence detector
    Accurate measurement range: 0.2-10000 (mg / kg)
    Precision: 5ppm ≤ 5%; 50ppm ≤ 2%
    Analysis time: 5min
    Injection volume: up to 100μL
    Calibration methods: external standard, straight or curved, can be sub-calibration

  • Introduction:
    TS6110 is Nordisk Tyco UV fluorescence total sulfur analyzer, which is also the second generation models.
    With three domestic initiative, automatic liquid injector, catalytic combustion technology, you can use the air as carrier gas and gas. Once introduced to the market, get a good market response.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com