SZ-CBS-B program - controlled part of the collector

Product ID:SHGCsjq033

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberSZ-CBS-B
    Brand NameSDSZYQYB
    Payment TermsT/T, paypal
    Features:
    Unique menu operation process. According to the "simple operation flow chart" on the panel, the operation of each function can be completed, and it is easy to use.
    Square design and mounted X - Y movement. The square design and the mounted x-y movement mode are adopted to ensure accurate positioning of pipe changing.
    Collect solution and circuit separation, use more safety.
    Corrosion resistant design. It is suitable for the column chromatography separation experiment of water-soluble and organic solvents.
    Programmable control. Microprocessor control, users can use the menu, according to the chromatographic map to compile the collection program. Various capacity collection and with waste liquid tank. A variety of test tube plates (sp-16a, sp-36a, sp-100a, sp-169a) are used freely to realize the multi-function of one machine. Selection (sp-36l) can realize continuous and infinite repeated collection, so as to further improve the efficiency of preparation. The waste liquid flows into the waste liquid tank automatically through the three - way valve and control procedure.
    Delay collection time can be set.
    The delay collection time is programmed to compensate the time from the detector exit to the collection tube, ensuring that the sample flows accurately into the corresponding tube.
    Solenoid valve change tube control.
    Control by electromagnetic valve to prevent leakage in the switching process.
    Technical indicators:
    1. Display mode: LCD Chinese blue screen display
    2. Collected test tubes: 169 (maximum capacity of each tube: 5ml with waste liquid tank)
    3. Timing range: 1 second - 999 hours, 59 minutes and 59 seconds
    4. Range of fixed drops: 1 drop -- 9999 drops are optional
    5. Optional selection of program control range: 1-10 paragraphs
    6. Moving mode: suspension x-y
    7. Pipe changing control: 12V dc electromagnetic valve
    8. Operation method: full Chinese menu type
    9. Program sequence number: 1 -- 10 / modes
    10. Power outage data preservation: 10 years
    11. Test tube tray: square design with waste liquid trough, free combination, optional (sp-169a, 36A, 16A type test tube rack, optional 36L type test tube rack for expansion collection)
    12. Power supply voltage: AC220V plus or minus 1 %;50 hz.1 0 w
    13. The use of the environment: 0-40 temperature humidity 85% or less
    Continuous working time: over 200 hours.
    15. Weight: 10kg
    16. External dimension: 355 x 360 x 270mm

     
  • Features:
    Unique menu operation process. According to the "simple operation flow chart" on the panel, the operation of each function can be completed, and it is easy to use.
    Square design and mounted X - Y movement. The square design and the mounted x-y movement mode are adopted to ensure accurate positioning of pipe changing.
    Collect solution and circuit separation, use more safety.
    Corrosion resistant design. It is suitable for the column chromatography separation experiment of water-soluble and organic solvents.
    Programmable control. Microprocessor control, users can use the menu, according to the chromatographic map to compile the collection program. Various capacity collection and with waste liquid tank. A variety of test tube plates (sp-16a, sp-36a, sp-100a, sp-169a) are used freely to realize the multi-function of one machine. Selection (sp-36l) can realize continuous and infinite repeated collection, so as to further improve the efficiency of preparation. The waste liquid flows into the waste liquid tank automatically through the three - way valve and control procedure.
    Delay collection time can be set.
    The delay collection time is programmed to compensate the time from the detector exit to the collection tube, ensuring that the sample flows accurately into the corresponding tube.
    Solenoid valve change tube control.
    Control by electromagnetic valve to prevent leakage in the switching process.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com