Position: Home > > Optical instruments and equipment > Industrial microscope > Metallurgical microscope > SGO-2005 Inverted Metallurgical Microscope

SGO-2005 Inverted Metallurgical Microscope

Product ID:GGXjx018

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberSGO-2005
    Brand NameSHENSHIGUANGGU
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    SGO-2005 Inverted Metallurgical Microscope
     
    Product Introduction
    The SGO-2005 Inverted Metallurgical Microscope is designed for microscopic observation and analysis of metal microstructures and material surface morphology. It is equipped with high-quality plan achromatic objectives and wide-field plan eyepieces to deliver clear, flat-field images.
    Its Kohler illumination system provides uniform field illumination, while the compact mechanical structure and ergonomic controls ensure convenient and comfortable operation. The microscope supports trinocular observation and optional digital imaging accessories, making it suitable for metallography, mineralogy, precision engineering, and materials science research.

     


    Performance Features
    1. Advanced Optical Observation System: Equipped with WF10X wide-field plan eyepieces and a 30° inclined trinocular observation head for comfortable viewing and convenient image documentation.
    2. Long-Working-Distance Objectives: Features long-working-distance plan achromatic objectives designed for metallurgical and material surface observation without a cover glass.
    3. Mechanical Stage: A double-layer mechanical stage with an integrated rotatable circular stage plate supports precise specimen positioning and polarized light observation.
    4. Kohler Illumination: Provides uniform illumination with adjustable aperture and field diaphragms for optimized image contrast and brightness.
    5. Polarization Observation: An optional polarizer with 90° adjustment allows observation of specimens under different polarization conditions.
    6. Coaxial Focusing System: Coarse and fine coaxial focusing with adjustable tension, locking, and travel-limiting mechanisms ensures precise focusing. Fine focusing graduation is 2 μm.
    7. Digital Imaging Expansion: Compatible with optional CCD, digital camera, and DSLR camera adapters for high-resolution image capture and documentation.
    8. Adjustable Halogen Illumination: Uses a 6V 20W halogen lamp with adjustable brightness to accommodate different observation requirements.

     


    Working Principle
    The SGO-2005 Inverted Metallurgical Microscope uses reflected-light microscopy to observe the microstructure and surface characteristics of opaque materials, including metals, alloys, and mineral samples.
    Light generated by the halogen illumination system passes through the optical illumination path and is directed onto the specimen surface through the objective lens. The reflected light is collected by the objective and transmitted through the optical system to the eyepieces or optional digital imaging device.
    The Kohler illumination system provides uniform field illumination, while the adjustable aperture and field diaphragms help optimize image contrast and resolution. The coaxial focusing mechanism enables precise adjustment of the specimen image for detailed microscopic examination.

     


    Technical Parameters
    Parameter Specification
    Model SGO-2005
    Microscope Type Inverted Metallurgical Microscope
    Eyepiece WF10X Wide-Field Plan Eyepiece
    Eyepiece Field Number Φ18 mm
    Observation Head Trinocular
    Observation Head Inclination 30°
    Objective Type Long-Working-Distance Plan Achromatic Objectives
    Standard Objectives PL 10X/0.25, PL L20X/0.40, PL L40X/0.60
    Objective Configuration 40X/50X/60X options (as specified by manufacturer)
    Optional Objective PL 100X/1.25, spring-loaded oil immersion
    Nosepiece Four-position revolving nosepiece with ball-bearing positioning
    Focusing System Coaxial coarse and fine focusing
    Fine Focusing Graduation 2 μm
    Focusing Adjustment Adjustable coarse focusing tension, locking and travel-limiting devices
    Mechanical Stage Double-layer mechanical stage
    Stage Dimensions 180 × 150 mm
    Stage Travel 15 × 15 mm
    Illumination Kohler illumination
    Light Source 6V 20W halogen lamp
    Brightness Adjustment Adjustable
    Filters Frosted glass, blue, green, and yellow filters
    Imaging Compatibility Optional CCD, digital camera, and DSLR camera adapters
     


    Application Scenarios
    • Metallographic Analysis: Observation and examination of metal grain structures, phases, inclusions, and metallographic specimens.
    •   Materials Science Research: Microscopic investigation of metals, alloys, and other engineering materials.
    •   Surface Morphology Inspection: Examination of material surface conditions, defects, and structural characteristics.
    • Mineralogy Research: Microscopic observation of mineral structures and optical properties.
    • Precision Engineering: Inspection and analysis of precision-engineered components and material surfaces.
    •  Quality Control Laboratories: Routine metallographic inspection and material quality assessment in industrial production.

     


    Comparison: SGO-2005 Inverted Metallurgical Microscope vs. Basic Metallurgical Microscope
    Feature SGO-2005 Basic Metallurgical Microscope
    Optical System Plan achromatic optics Depends on configuration
    Observation Head Trinocular, 30° inclined Typically binocular
    Illumination Kohler illumination Basic reflected-light illumination
    Focusing Coaxial coarse and fine focusing Depends on model
    Fine Focusing Graduation 2 μm Model-dependent
    Mechanical Stage Double-layer mechanical stage Standard mechanical stage
    Polarization Observation Optional rotatable stage and polarizer Configuration-dependent
    Digital Imaging Optional CCD, digital camera, and DSLR adapters Depends on configuration
    Applications Metallography, materials research, surface inspection General metallographic observation
     


    Frequently Asked Questions (FAQ)
    Q1: What is the SGO-2005 Inverted Metallurgical Microscope used for?
    It is designed for observing and analyzing metal microstructures, material surface morphology, minerals, and precision-engineered components.
    Q2: What type of illumination does the SGO-2005 use?
    It uses a Kohler illumination system with a 6V 20W halogen lamp and adjustable brightness, providing uniform illumination for microscopic observation.
    Q3: What objectives are available for this microscope?
    The standard objective options include PL 10X/0.25, PL L20X/0.40, and PL L40X/0.60 long-working-distance plan achromatic objectives. A PL 100X/1.25 spring-loaded oil immersion objective is available as an option.
    Q4: Does the SGO-2005 support digital image capture?
    Yes. Its trinocular observation head can be equipped with optional CCD, digital camera, or DSLR camera adapters for image capture and documentation.
    Q5: Can the microscope perform polarized light observation?
    Yes. The integrated rotatable circular stage plate and optional polarizer with 90° adjustment support polarized light observation.
    Q6: What is the fine focusing accuracy of the SGO-2005?
    The fine focusing graduation is 2 μm, allowing precise adjustment during microscopic observation.
    Q7: What is the size of the mechanical stage?
    The double-layer mechanical stage measures 180 × 150 mm, with a movement range of 15 × 15 mm.
    Q8: Which industries can benefit from the SGO-2005?
    It is suitable for metallurgical laboratories, materials science research, mineralogy, precision engineering, industrial inspection, and quality control applications.


     
     
     
  • Frequently Asked Questions (FAQ)
    Q1: What is the SGO-2005 Inverted Metallurgical Microscope used for?
    It is designed for observing and analyzing metal microstructures, material surface morphology, minerals, and precision-engineered components.
    Q2: What type of illumination does the SGO-2005 use?
    It uses a Kohler illumination system with a 6V 20W halogen lamp and adjustable brightness, providing uniform illumination for microscopic observation.
    Q3: What objectives are available for this microscope?
    The standard objective options include PL 10X/0.25, PL L20X/0.40, and PL L40X/0.60 long-working-distance plan achromatic objectives. A PL 100X/1.25 spring-loaded oil immersion objective is available as an option.
    Q4: Does the SGO-2005 support digital image capture?
    Yes. Its trinocular observation head can be equipped with optional CCD, digital camera, or DSLR camera adapters for image capture and documentation.
    Q5: Can the microscope perform polarized light observation?
    Yes. The integrated rotatable circular stage plate and optional polarizer with 90° adjustment support polarized light observation.
    Q6: What is the fine focusing accuracy of the SGO-2005?
    The fine focusing graduation is 2 μm, allowing precise adjustment during microscopic observation.
    Q7: What is the size of the mechanical stage?
    The double-layer mechanical stage measures 180 × 150 mm, with a movement range of 15 × 15 mm.
    Q8: Which industries can benefit from the SGO-2005?
    It is suitable for metallurgical laboratories, materials science research, mineralogy, precision engineering, industrial inspection, and quality control applications.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com