Position: Home > > Life science instrument and equipment > Molecular biology instrument > DNA synthesis > SCIENTZ08-IIID Non-Contact Ultrasonic DNA Shearing System

SCIENTZ08-IIID Non-Contact Ultrasonic DNA Shearing System

Product ID:SHFZdnahc003

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberSCIENTZ08-IIID
    Brand NameNBXINZHI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    SCIENTZ08-IIID Non-Contact Ultrasonic DNA Shearing System
    Product Overview
    The SCIENTZ08-IIID Non-Contact Ultrasonic DNA Shearing System is an advanced laboratory instrument designed for highly efficient, contamination-free DNA fragmentation and biological sample processing. Utilizing isothermal, non-contact ultrasonic technology, the system performs DNA shearing, chromatin fragmentation, cell disruption, protein extraction, and sample homogenization without direct contact between the ultrasonic probe and the sample.
    Developed specifically for Next-Generation Sequencing (NGS) library preparation and Chromatin Immunoprecipitation (ChIP) workflows, the SCIENTZ08-IIID offers exceptional reproducibility, minimal sample loss, high biosafety, and excellent processing consistency. Multiple sealed centrifuge tubes can be processed simultaneously, making it ideal for laboratories requiring reliable high-throughput sample preparation.

     
    Key Features
    • Non-contact ultrasonic processing eliminates probe contamination and aerosol generation.
    • 4.3-inch medical-grade resistive touchscreen with intuitive operation.
    • Stores up to 50 experimental programs for repeatable workflows.
    • Ultra-low operating noise (<55 dB) for comfortable laboratory environments.
    • Continuous and pulse sonication modes available.
    • Adjustable ultrasonic power (1–100%) for precise fragmentation control.
    • Automatic rotating sample tubes ensure uniform ultrasonic energy distribution.
    • Integrated temperature-controlled cooling system maintains sample integrity.
    • Comprehensive safety protection, including over-current, over-voltage, and over-temperature alarms.

     
    Working Principle
    Unlike conventional probe-type ultrasonic homogenizers that generate cavitation only near the probe tip, the SCIENTZ08-IIID employs ultrasonic transducers mounted beneath the water bath. This configuration distributes ultrasonic energy uniformly throughout the entire ultrasonic chamber.
    During operation, sealed centrifuge tubes continuously rotate within the ultrasonic bath, ensuring each sample receives identical ultrasonic exposure. Because the samples remain sealed throughout processing, there is:
    • No direct probe contact
    • No cross contamination
    • No aerosol formation
    • Minimal sample loss
    • Improved biological safety
    The constant-temperature cooling system further prevents heat accumulation, preserving DNA quality and improving fragmentation consistency.

     
    Technical Specifications
    Parameter SCIENTZ08-IIID
    Sample Tube Size 0.1 ml–15 ml
    Display 4.3-inch Medical-grade Resistive Touchscreen
    Display Information Time, Temperature, Power
    Operating Modes Pulse / Continuous
    Total Sonication Time 0.1 s–9999 min
    Pulse Working Time 0.1–99.9 s
    Pulse Interval 0–99.9 s (0 = Continuous Mode)
    Ultrasonic Power 1–100% Adjustable
    Ultrasonic Bath Size 300 × 150 × 100 mm
    Recommended Sample Volume >2 ml or <5 μl
    Standard Adapters 32 × 0.1/0.2 ml ×3 sets; 20 × 0.5/0.65 ml ×3 sets
    Sample Capacity 32 × 0.1/0.2 ml ×3 sets; 20 × 0.5/0.65 ml ×3 sets; 12 × 1.5/2 ml ×3 sets; 5 × 5–15 ml tubes ×3 sets
    Adapter Material 316 Stainless Steel
    Noise Level <55 dB
    Cooling System Portable Refrigerated Constant-Temperature Circulator
    Temperature Control Range 2–40°C
    Temperature Display Resolution 0.1°C
    Refrigeration Power 600 W
     
    Typical Applications
    The SCIENTZ08-IIID is suitable for a wide range of molecular biology and life science applications, including:
    • DNA fragmentation for Next-Generation Sequencing (NGS)
    • Chromatin Immunoprecipitation (ChIP)
    • Cell disruption and cell lysis
    • Protein extraction
    • Inclusion body extraction
    • Micro-emulsification
    • Genomic DNA preparation
    • Molecular biology research
    • Biotechnology laboratories
    • Clinical research laboratories
    • Pharmaceutical R&D
    • Academic research institutions

     
    Why Choose the SCIENTZ08-IIID?
    Feature SCIENTZ08-IIID Non-Contact System Conventional Probe Sonicator
    Sample Contact No direct contact Direct probe contact
    Cross Contamination None Possible
    Aerosol Generation No Yes
    Biosafety High Moderate
    Temperature Stability Excellent Heat buildup possible
    Sample Uniformity Excellent Depends on probe position
    High-Throughput Processing Yes Limited
    Sample Loss Very Low Higher
    Suitable for Precious Samples Excellent Moderate
    Workflow Repeatability Excellent Good
     
    Frequently Asked Questions (FAQ)
    What is the main advantage of a non-contact ultrasonic DNA shearing system?
    The non-contact design prevents direct probe contamination, eliminates cross contamination between samples, and improves biosafety while maintaining highly reproducible DNA fragmentation.
    Is the SCIENTZ08-IIID suitable for NGS library preparation?
    Yes. It is specifically designed for DNA fragmentation required in Next-Generation Sequencing (NGS) sample preparation.
    Can the system perform ChIP sample preparation?
    Yes. The instrument is optimized for chromatin fragmentation in Chromatin Immunoprecipitation (ChIP) workflows.
    Does the system include temperature control?
    Yes. It incorporates a compressor-based constant-temperature cooling system with a control range of 2–40°C, protecting temperature-sensitive biological samples.
    What sample tubes are supported?
    The instrument accommodates centrifuge tubes ranging from 0.1 ml to 15 ml, with multiple adapter configurations for high-throughput processing.
    Can ultrasonic parameters be customized?
    Yes. Sonication time, pulse interval, total processing time, and output power are all fully programmable.

     
    Ideal Industries
    • Molecular Biology Laboratories
    • Genomics Research Centers
    • Biotechnology Companies
    • Pharmaceutical Research
    • Clinical Laboratories
    • Medical Research Institutes
    • Universities
    • Life Science Research Facilities
    • Precision Medicine Laboratories
    • Genetic Testing Centers

     
    The Ideal Solution for High-Quality DNA Fragmentation
    The SCIENTZ08-IIID Non-Contact Ultrasonic DNA Shearing System combines contamination-free ultrasonic technology, programmable operation, temperature-controlled processing, and high-throughput capability to deliver reliable DNA fragmentation and biological sample preparation. It is an ideal solution for laboratories performing NGS, ChIP, chromatin research, and advanced molecular biology workflows, providing excellent reproducibility, biosafety, and experimental efficiency.
     

     
  • Frequently Asked Questions (FAQ)
    What is the main advantage of a non-contact ultrasonic DNA shearing system?
    The non-contact design prevents direct probe contamination, eliminates cross contamination between samples, and improves biosafety while maintaining highly reproducible DNA fragmentation.
    Is the SCIENTZ08-IIID suitable for NGS library preparation?
    Yes. It is specifically designed for DNA fragmentation required in Next-Generation Sequencing (NGS) sample preparation.
    Can the system perform ChIP sample preparation?
    Yes. The instrument is optimized for chromatin fragmentation in Chromatin Immunoprecipitation (ChIP) workflows.
    Does the system include temperature control?
    Yes. It incorporates a compressor-based constant-temperature cooling system with a control range of 2–40°C, protecting temperature-sensitive biological samples.
    What sample tubes are supported?
    The instrument accommodates centrifuge tubes ranging from 0.1 ml to 15 ml, with multiple adapter configurations for high-throughput processing.
    Can ultrasonic parameters be customized?
    Yes. Sonication time, pulse interval, total processing time, and output power are all fully programmable.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com