RNA-3000 Air Generator

Product ID:SYQFCkq016

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberRNA-3000
    Brand NameSDRUINENG
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    RNA-3000 Air Generator
     (Clean Dry Air Generator for Laboratory Use)
    Product Introduction
    The RNA-3000 Air Generator is a laboratory-grade clean and dry air supply system designed by our gas source division to provide high-purity compressed air for analytical instruments and laboratory environments. Using a cold-drying and multi-stage purification system, the RNA series ensures stable, oil-free, and moisture-free air output.
    It is widely used in laboratories requiring continuous clean compressed air, and supports customized configurations to meet specific application needs.

     
    Key Features
       • Dual-stage purification filtration system ensures clean and dry air output
       • Built-in oil-free, low-noise air compressor for quiet laboratory operation
       • Stainless steel air storage tank with electro-polished and passivated pipeline system
       • Ultrasonic cleaning process improves internal cleanliness and system reliability
       • Low-pressure solenoid valve enables continuous 24/7 operation
       • Stable output suitable for unattended laboratory environments
       • Customizable design available for different laboratory requirements
       • High reliability for long-term continuous operation
    Working Principle
    The RNA-3000 Air Generator operates through a compression–filtration–drying–stabilization process:

       • Air is compressed by an oil-free low-noise compressor
       • The compressed air passes through a dual-stage purification system
       • Moisture and impurities are removed during cold drying and filtration
       • Clean air is stored in a stainless steel buffer tank
       • A pressure stabilization system ensures continuous, stable output flow
    This ensures consistent clean dry air supply for laboratory instruments.
     
    Technical Specifications
    Parameter Specification
    Output Flow Rate 0–3000 mL/min
    Output Pressure 0–0.4 MPa
    Pressure Stability < 0.2%
    Noise Level < 35 dB(A)
    Power Supply 220V ±10%, 50–60 Hz
    Operating Temperature 0–40°C
    Ambient Humidity < 85% RH
     
    Application Areas
    The RNA-3000 Air Generator is widely used in:

       • Analytical chemistry laboratories
       • Gas chromatography (GC) systems
       • Mass spectrometry support systems
       • Environmental monitoring laboratories
       • Pharmaceutical and biotech research labs
       • Food safety testing laboratories
       • University and research institute labs
       • Continuous unattended laboratory gas supply systems
    Product Comparison
    Compared with traditional air compressors, the RNA-3000 Air Generator offers significant advantages:

       • Unlike oil-lubricated compressors, it provides oil-free air output, preventing contamination of analytical instruments
       • Compared to standard compressors, it delivers lower noise (<35 dB) for a quieter lab environment
       • Traditional systems lack advanced purification, while RNA-3000 uses dual-stage filtration for higher purity air
       • Standard compressors require frequent maintenance, whereas RNA-3000 is designed for long-term continuous operation with minimal maintenance
    Overall, the RNA-3000 is optimized for precision laboratory applications requiring stable and clean air supply.
     
    FAQ
    Q1: Is the RNA-3000 suitable for gas chromatography systems?
    Yes. It provides stable, oil-free, and dry air ideal for GC and other analytical instruments.
    Q2: Does it require external air purification equipment?
    No. The built-in dual purification system already ensures clean and dry output air.
    Q3: Can it run continuously for long periods?
    Yes. It is designed for 24/7 continuous operation with low-pressure solenoid control.
    Q4: How noisy is the system?
    The operating noise is below 35 dB(A), suitable for quiet laboratory environments.
    Q5: Can the system be customized?
    Yes. Customized configurations are available based on laboratory requirements.

  • FAQ
    Q1: Is the RNA-3000 suitable for gas chromatography systems?
    Yes. It provides stable, oil-free, and dry air ideal for GC and other analytical instruments.
    Q2: Does it require external air purification equipment?
    No. The built-in dual purification system already ensures clean and dry output air.
    Q3: Can it run continuously for long periods?
    Yes. It is designed for 24/7 continuous operation with low-pressure solenoid control.
    Q4: How noisy is the system?
    The operating noise is below 35 dB(A), suitable for quiet laboratory environments.
    Q5: Can the system be customized?
    Yes. Customized configurations are available based on laboratory requirements.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com