QWA-5A Quartz Clock and Watch Tester

Product ID:CLQTsjpljly003

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberQWA-5A
    Brand NameGZZHIHUIYUAN
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    QWA-5A Quartz Clock and Watch Tester
    Product Overview
    The QWA-5A Quartz Clock and Watch Tester is a precision measurement instrument widely used in the quartz clock and watch industry. It is primarily designed to measure the frequency accuracy of quartz crystals used in clocks and watches and to evaluate the timekeeping accuracy of various quartz clocks, watches and electronic devices.
    The QWA-5A can measure daily error, monthly error and ppm-level frequency deviation of quartz clocks, watches and quartz crystals. Its probe-type accessory is suitable for testing a wide variety of finished and semi-finished products.
    With high reliability and stability, the QWA-5A is designed for demanding production environments. It can maintain stability within 0.5 ppm over a relatively wide ambient temperature range, making it suitable for precision quality control and production testing.

     

    Key Features
    • Designed specifically for precision testing in the quartz clock and watch industry
    • Measures quartz crystal frequency accuracy
    • Measures timekeeping accuracy of quartz clocks and watches
    • Supports daily error measurement
    • Supports monthly error measurement
    • Displays clock, watch and crystal frequency deviation in ppm
    • Probe-type accessory suitable for finished and semi-finished product testing
    • High reliability and excellent long-term stability
    • Maintains stability within 0.5 ppm over a wide ambient temperature range
    • Suitable for production environments and quality control applications
    • Compact design for convenient installation and operation

     

    Working Principle
    The QWA-5A evaluates the frequency accuracy and timekeeping performance of quartz-controlled clocks, watches and electronic devices by measuring their timing or oscillation frequency deviation from the reference standard.
    During testing, the probe accessory can be connected to or positioned at the appropriate measurement point of the finished or semi-finished product. The instrument detects the frequency deviation and calculates the corresponding timekeeping error.
    Measurement results can be expressed in ppm, while clock and watch performance can also be evaluated through daily error and monthly error, providing a convenient method for production inspection and quality control.

     

    Measurement Functions
    The QWA-5A supports precision measurement of:
    • Quartz crystal frequency accuracy
    • Quartz clock timekeeping accuracy
    • Quartz watch timekeeping accuracy
    • Daily clock/watch error
    • Monthly clock/watch error
    • Quartz crystal frequency deviation
    • Clock and watch frequency deviation in ppm

     

    Technical Specifications
    Parameter Specification
    Model QWA-5A
    Measurement Range 1000 ppm
    Accuracy 0.5 ppm
    Measurement Application Quartz clocks, watches, quartz crystals and electronic timing devices
    Probe Probe-type accessory for finished and semi-finished products
    Dimensions 20 × 40 × 30 cm
    Weight 5 kg
     

    Applications
    The QWA-5A Quartz Clock and Watch Tester is suitable for precision measurement, production inspection and quality control in the quartz timing industry.
    Typical applications include:
    • Quartz clock testing
    • Quartz watch testing
    • Quartz crystal frequency testing
    • Clock timekeeping accuracy measurement
    • Watch timekeeping accuracy measurement
    • Quartz crystal frequency deviation measurement
    • Finished quartz clock and watch inspection
    • Semi-finished product testing
    • Production-line quality control
    • R&D and precision testing of quartz timing components

     

    Application Scenarios
    Quartz Clock Manufacturing
    The QWA-5A can be used to inspect the timekeeping accuracy and frequency deviation of quartz clocks during production and final quality inspection.
    Quartz Watch Manufacturing
    It provides ppm-level measurement of frequency deviation and can be used to evaluate the daily and monthly timekeeping error of quartz watches.
    Quartz Crystal Testing
    The instrument can be used to evaluate the frequency accuracy of quartz crystals used as timing components in clocks and watches.
    Finished and Semi-Finished Product Testing
    The probe-type accessory allows testing of different product forms, making the QWA-5A suitable for both finished products and semi-finished assemblies.
    Production Quality Control
    Its high stability and 0.5 ppm accuracy make it suitable for precision inspection in quartz clock and watch manufacturing environments.

     

    QWA-5A vs. Conventional Timekeeping Testing
    Feature QWA-5A Quartz Clock and Watch Tester Conventional Basic Timekeeping Tester
    Quartz Crystal Frequency Testing Supported Depends on equipment
    Clock Accuracy Testing Supported Supported
    Watch Accuracy Testing Supported Depends on equipment
    Daily Error Measurement Supported Depends on equipment
    Monthly Error Measurement Supported Depends on equipment
    ppm Display Supported Not always available
    Finished Product Testing Supported with probe Depends on configuration
    Semi-Finished Product Testing Supported Depends on configuration
    Accuracy 0.5 ppm Depends on equipment
    Production Application Suitable Depends on equipment
    The QWA-5A combines quartz crystal frequency testing with clock and watch timekeeping accuracy measurement, providing a practical solution for precision testing and production quality control in the quartz timing industry.
     

    FAQ
    What is the QWA-5A Quartz Clock and Watch Tester used for?
    The QWA-5A is used to measure the frequency accuracy of quartz crystals and the timekeeping accuracy of quartz clocks, watches and related electronic timing products.
    Can the QWA-5A measure clock and watch daily error?
    Yes. The instrument can measure the daily error of quartz clocks and watches.
    Can it measure monthly error?
    Yes. The QWA-5A supports measurement of monthly timekeeping error.
    Does the QWA-5A display measurement results in ppm?
    Yes. Frequency deviation and timing errors can be expressed in ppm, allowing convenient evaluation of quartz crystal and timepiece accuracy.
    What is the measurement range?
    The specified measurement range is 1000 ppm.
    What is the accuracy of the QWA-5A?
    The specified measurement accuracy is 0.5 ppm.
    Can the QWA-5A test finished quartz clocks and watches?
    Yes. The probe-type accessory is designed for testing various finished and semi-finished products.
    Is the QWA-5A suitable for production environments?
    Yes. The instrument features high reliability and stability and can maintain stability within 0.5 ppm over a relatively wide ambient temperature range, making it suitable for production inspection and quality control.
    What products can be tested with the QWA-5A?
    Typical test objects include quartz clocks, quartz watches, quartz crystals and related electronic timing products such as mainboards, PDAs and DSC devices.
     

     
     
  • FAQ
    What is the QWA-5A Quartz Clock and Watch Tester used for?
    The QWA-5A is used to measure the frequency accuracy of quartz crystals and the timekeeping accuracy of quartz clocks, watches and related electronic timing products.
    Can the QWA-5A measure clock and watch daily error?
    Yes. The instrument can measure the daily error of quartz clocks and watches.
    Can it measure monthly error?
    Yes. The QWA-5A supports measurement of monthly timekeeping error.
    Does the QWA-5A display measurement results in ppm?
    Yes. Frequency deviation and timing errors can be expressed in ppm, allowing convenient evaluation of quartz crystal and timepiece accuracy.
    What is the measurement range?
    The specified measurement range is 1000 ppm.
    What is the accuracy of the QWA-5A?
    The specified measurement accuracy is 0.5 ppm.
    Can the QWA-5A test finished quartz clocks and watches?
    Yes. The probe-type accessory is designed for testing various finished and semi-finished products.
    Is the QWA-5A suitable for production environments?
    Yes. The instrument features high reliability and stability and can maintain stability within 0.5 ppm over a relatively wide ambient temperature range, making it suitable for production inspection and quality control.
    What products can be tested with the QWA-5A?
    Typical test objects include quartz clocks, quartz watches, quartz crystals and related electronic timing products such as mainboards, PDAs and DSC devices.
     

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com