    Product Introduction
    The PC2000 Industrial Fiber Optic Spectrometer is a compact, high-resolution optical spectrometer designed for precision spectral measurement, OEM integration and customized optical systems. It provides up to 0.1 nm optical resolution while maintaining a compact structure.
    With a 100 mm focal length and 0.11 numerical aperture, the optical platform achieves a balanced combination of spectral resolution and sensitivity without increasing the spectrometer size. Its EX dual-blazed grating technology provides more uniform response across a wide spectral range and helps address efficiency balance and higher-order spectral interference.
    The PC2000 can also be equipped with a specially UV-sensitized deep-UV CCD to extend detection into the deep-UV region. Flag-status and low-level calling technologies support fast measurement, system integration and customized spectrometer application development.

     


    Performance Features
    1.  High-resolution optical platform
    Optimizes resolution and sensitivity within a compact spectrometer structure.
    2. Wide spectral coverage
    Variable-blazed gratings and linear-gradient order-sorting filters help balance efficiency across a broad spectral range and reduce higher-order interference.
    3. High optical resolution
    Optical resolution can reach 0.1 nm, depending on configuration.
    4. EX dual-blazed grating technology
    Provides a more uniform response over wide spectral bands, with the broadest configurable coverage reaching 200–1100 nm.
    5. High-speed control
    A new integration time can be set within 1 ms, reducing spectrometer control overhead.
    5. Flag-status technology
    Enables users to check acquisition completion status and interrupt or restart acquisition without prolonged waiting.
    6. Low-level calling technology
    Supports system integration and application development for customized spectrometer solutions.
    7. Flexible optical configuration
    Multiple slit sizes, gratings, filters and fiber interfaces can be selected or customized.

     


    Working Principle
    The PC2000 receives optical radiation through a fiber optic interface. The incoming light is directed into the spectrometer's optical system, where the optical components collimate and disperse the light according to wavelength.
    The selected diffraction grating separates the incoming spectrum, and the dispersed light is projected onto the TCD1304DG linear CCD array. The CCD converts the optical signal into electrical signals, which are digitized by the 16-bit A/D converter.
    The resulting spectral data can then be processed by the host system for wavelength identification, intensity analysis and other customized spectral measurement applications. Depending on the selected grating, slit and detector configuration, the PC2000 can provide different spectral ranges and resolutions.

     


    Technical Specifications
    General Specifications
    Parameter Specification
    Model PC2000
    Product Type Industrial Fiber Optic Spectrometer
    Dimensions 115 × 158 × 46.5 mm
    Weight 600 g
    Spectral Range 200–1100 nm, depending on grating
    Maximum Optical Resolution Up to 0.1 nm
    Integration Time 1 ms–2 s
    Dynamic Range 300
    SNR 300:01:00 (full spectral range)
    Wavelength Tolerance About ±0.2
    Corrected Linearity >99.8%
    Detector Specifications
    Parameter Specification
    Detector TCD1304DG linear CCD array
    Detector Response Range 300–1100 nm
    Effective Pixels 3648
    Pixel Size 8 × 200 µm
    A/D Resolution 16 bit
    Photoresponse Non-uniformity ≤1%
    Sensitivity 130 photons/count at 400 nm; 60 photons/count at 600 nm
    Optical System
    Parameter Specification
    Optical System F/4, f/4, symmetrical crossed optical path
    Focal Length 100 mm
    Slit Sizes 5, 10, 25, 50, 100, 200 µm, etc.; slitless configuration available by customization
    Grating Ruled or holographic gratings with different parameters; customizable
    Cylindrical Mirrors Optional
    Order-Sorting Filter Band-pass or long-pass filters available
    Fiber Interface NA 0.22, SMA905
    Spectral Resolution Approx. 0.035–8.4 nm FWHM, depending on grating constant, slit width and detector
    Optical Performance
    Parameter Specification
    Spectral Coverage 200–1100 nm, depending on grating
    Stray Light <0.05% at 600 nm; <0.10% at 435 nm
    Corrected Linearity >99.8%
    Integration Time Setting 1 ms–2 s
     


    Application Scenarios
    The PC2000 industrial fiber optic spectrometer is suitable for:
    •   Industrial optical measurement
    •   UV-visible spectral analysis
    •   Light source characterization
    •   LED and semiconductor optical testing
    •   Color and material analysis
    •   Laboratory spectral measurement
    •   OEM optical instruments
    •   Customized spectroscopy systems
    •   Process and production monitoring
    •   Fiber-optic spectroscopy
    •   Scientific research and teaching

     


    PC2000 vs. Conventional Compact Spectrometers
    Feature PC2000 Fiber Optic Spectrometer Conventional Compact Spectrometer
    Optical Resolution Up to 0.1 nm Depends on configuration
    Spectral Coverage Up to 200–1100 nm Often configuration-dependent
    Optical Platform 100 mm focal length, compact design Varies
    Grating Options Ruled/holographic, customizable Usually limited options
    Slit Options Multiple slit widths or slitless customization Usually fixed or limited
    Fiber Interface NA 0.22, SMA905 Depends on model
    Integration Time 1 ms–2 s Depends on model
    Control High-speed control and status flags Depends on software/system
    System Integration Supports low-level calling and customized development May require dedicated software
    OEM Customization Optical components and configuration can be customized Usually more limited
     


    FAQ
    1.  What is the maximum optical resolution of the PC2000?
    The PC2000 can provide optical resolution of up to 0.1 nm, depending on the selected optical configuration.
    2. What spectral range does the PC2000 cover?
    The broadest stated spectral coverage is 200–1100 nm, depending on the selected diffraction grating and detector configuration.
    3. What detector does the PC2000 use?
    The standard configuration uses a TCD1304DG linear CCD array with 3648 effective pixels.
    4. What is the integration time range?
    The integration time ranges from 1 ms to 2 seconds.
    5. Can the PC2000 be customized?
    Yes. Slit sizes, diffraction gratings, cylindrical mirrors, filters and other optical configurations can be selected or customized according to application requirements.
    6. What fiber interface is used?
    The standard fiber interface is SMA905, with a numerical aperture of NA 0.22.
    7. Can the PC2000 be integrated into an OEM instrument?
    Yes. Its flag-status technology and low-level calling technology support system integration and customized application development.
    8. Can the PC2000 be used for UV spectral measurement?
    Yes. The standard detector covers 300–1100 nm, while a specially UV-sensitized deep-UV CCD can be configured to extend the detection range toward the deep-UV region.
    9. What factors determine the actual spectral resolution?
    The actual resolution depends mainly on the grating constant, slit width and detector configuration. The specified configurable resolution is approximately 0.035–8.4 nm FWHM.


  • FAQ
    1.  What is the maximum optical resolution of the PC2000?
    The PC2000 can provide optical resolution of up to 0.1 nm, depending on the selected optical configuration.
    2. What spectral range does the PC2000 cover?
    The broadest stated spectral coverage is 200–1100 nm, depending on the selected diffraction grating and detector configuration.
    3. What detector does the PC2000 use?
    The standard configuration uses a TCD1304DG linear CCD array with 3648 effective pixels.
    4. What is the integration time range?
    The integration time ranges from 1 ms to 2 seconds.
    5. Can the PC2000 be customized?
    Yes. Slit sizes, diffraction gratings, cylindrical mirrors, filters and other optical configurations can be selected or customized according to application requirements.
    6. What fiber interface is used?
    The standard fiber interface is SMA905, with a numerical aperture of NA 0.22.
    7. Can the PC2000 be integrated into an OEM instrument?
    Yes. Its flag-status technology and low-level calling technology support system integration and customized application development.
    8. Can the PC2000 be used for UV spectral measurement?
    Yes. The standard detector covers 300–1100 nm, while a specially UV-sensitized deep-UV CCD can be configured to extend the detection range toward the deep-UV region.
    9. What factors determine the actual spectral resolution?
    The actual resolution depends mainly on the grating constant, slit width and detector configuration. The specified configurable resolution is approximately 0.035–8.4 nm FWHM.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com