Position: Home > > Environmental monitoring and analysis > Airborne particulate matter > Particle counter > LPC-5100 High-Flow Laser Particle Counter

LPC-5100 High-Flow Laser Particle Counter

Product ID:HQKLlzjs030

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberLPC-5100
    Brand NameSZSHANGTIANJIEJING
    Payment TermsT/T, paypal,Alibaba.com Pay
    LPC-5100 High-Flow Laser Particle Counter
     
    Product Introduction
    The LPC-5100 High-Flow Laser Particle Counter is a high-flow airborne particle counter developed according to the requirements of the revised GMP 2010. With a sampling flow rate of 100 L/min (3.53 CFM), it is designed for rapid and reliable particle monitoring in cleanrooms and controlled environments.
    The LPC-5100 features a durable SUS 316L stainless steel housing, a semiconductor laser sensor and an imported electronic flow sensor. Its 8-inch color touchscreen provides clear data display and convenient operation. The instrument can automatically determine cleanroom cleanliness levels according to selected standards and supports real-time measurement, UCL calculation, data storage and report printing.
    It is widely used in medical, pharmaceutical, electronics, chemical, optical, food, cosmetics, biological product and aerospace industries, as well as professional testing institutions.

     


    Performance Features
    •  High-flow sampling: Provides a sampling flow rate of 100 L/min, or 3.53 CFM, for efficient cleanroom particle monitoring.
    • SUS 316L stainless steel housing: Suitable for demanding laboratory, pharmaceutical and cleanroom environments.
    •  Stable laser detection: Uses a semiconductor laser with a service life of more than 10 years or 50,000 hours.
    • High signal-to-noise ratio: The optimized optical system reduces stray scattered light in the scattering chamber and improves detection accuracy.
    •  8-inch color touchscreen: Supports Chinese and English interfaces with clear graphical operation.
    •  Multiple display modes: Displays real-time data, previous-cycle data, particle concentration, time, date, temperature, humidity, room number, sampling point, sampling count and instrument status.
    •  Six particle-size channels: Simultaneously displays 0.5, 0.7, 1.0, 3.0, 5.0 and 10.0 μm channels. A 25 μm channel is available as an option.
    • Flexible sampling settings: Supports single measurement, calculated measurement and confidence-level measurement.
    • Automatic cleanliness classification: Supports automatic alarm and classification according to selected cleanroom standards.
    • UCL calculation: Reports comply with ISO 14644-1, GMP 2010, 209E, YY0033-2000 and GB50687-2011.
    •  Large data storage: Stores at least 20,000 single-measurement records or 10,000 UCL records.
    • Built-in thermal printer: Prints particle-size channels, measured values, calculated values, UCL values and cleanliness-level results.
    •  USB data export: Enables convenient transfer of stored measurement data.
    •  Rechargeable battery: Built-in 16.8V high-capacity lithium battery provides approximately 4 hours of operation.
    •  Optional advanced functions: Automatic flow adjustment, temperature and humidity measurement, three-level user password management and audit trail.

     


    Working Principle
    The LPC-5100 draws a measured volume of air through an isokinetic sampling head and sampling tube. Airborne particles pass through the laser detection chamber, where the semiconductor laser illuminates the particles.
    When particles pass through the laser beam, they produce scattered light. The semiconductor photodiode receives the scattered light and converts it into electrical signals. The instrument analyzes the signal intensity to determine particle size and counts the number of particles in each size channel.
    The instrument then calculates particle concentration in particles per cubic meter. According to the selected cleanroom or regulatory standard, it can calculate UCL values, determine the applicable cleanliness level and issue an alarm when the measured concentration exceeds the configured limit.

     


    Technical Parameters
    Parameter Specification
    Product Model LPC-5100
    Product Type High-flow laser particle counter
    Housing Material SUS 316L stainless steel
    Light Source Semiconductor laser
    Laser Service Life More than 10 years or 50,000 hours
    Sampling Flow Rate 100 L/min (3.53 CFM)
    Display 8-inch color touchscreen
    Interface Chinese/English selectable
    Measurement Modes Single measurement, calculated measurement and confidence-level measurement
    Standard Particle-Size Channels 0.5, 0.7, 1.0, 3.0, 5.0 and 10.0 μm
    Optional Particle-Size Channel 25 μm
    Sampling Period 1–99 min 99 sec
    Delay Time 0–99 sec
    Interval Time 0–999 sec
    Continuous Sampling Count 0–99 times
    Self-Cleaning Time ≤10 min
    UCL Standards ISO 14644-1, GMP 2010, 209E, YY0033-2000 and GB50687-2011
    Data Storage ≥20,000 single measurements or ≥10,000 UCL records
    Alarm Levels Cleanroom classes 100, 1,000, 10,000, 100,000, 300,000 and 1,000,000
    GMP Classification Supports static and dynamic A, B, C and D grades
    Printer Built-in thermal printer
    Printed Paper Storage Life Approximately 10 years under normal storage conditions
    Battery Built-in 16.8V high-capacity lithium battery
    Battery Operating Time Approximately 4 hours
    Power Adapter AC 80–240V, 50/60Hz
    Data Export USB interface
    Dimensions 460 × 350 × 240 mm (W × D × H)
    Weight Approximately 11 kg
    Standard Accessories Isokinetic sampling head, 1.8 m sampling tube, sampling support, zero-count filter, power cord, printer paper and standard carrying case
     


    Optional Functions
    Optional Function Specification
    Automatic Flow Adjustment Built-in gas mass flow controller
    Temperature and Humidity Probe Temperature: −40°C to +123.8°C; humidity: 0–100% RH
    Temperature Accuracy ±0.4°C
    Humidity Accuracy ±3% RH
    Three-Level User Management User-defined passwords and operator permissions
    Audit Trail Available as an optional function
    25 μm Particle Channel Available as an option
     


    Application Scenarios
    The LPC-5100 high-flow laser particle counter is suitable for:
    •  Pharmaceutical cleanroom monitoring
    •  Medical and healthcare facility testing
    •  Sterile production areas
    •  Electronics and semiconductor manufacturing
    •  Chemical and optical production environments
    •  Food and cosmetics manufacturing
    •  Biological product laboratories
    •  Aerospace cleanroom testing
    •  Cleanroom qualification and requalification
    •  Environmental monitoring by testing institutions
    •  GMP cleanliness classification and routine particle measurement
    •  Monitoring of airborne particles in controlled environments

     


    Product Comparison
    Feature LPC-5100 High-Flow Laser Particle Counter Conventional Low-Flow Particle Counter
    Sampling Flow Rate 100 L/min (3.53 CFM) Usually lower flow rate
    Sampling Efficiency Rapid sampling of large air volumes Requires longer sampling time for equivalent air volume
    Particle Channels Six standard channels, optional 25 μm channel Depends on model
    Display 8-inch color touchscreen Usually smaller display
    Cleanroom Classification Supports automatic classification according to selected standards May require manual calculation
    UCL Calculation Supported May not be available
    Data Storage ≥20,000 single measurements or ≥10,000 UCL records Usually smaller storage capacity
    Report Printing Built-in thermal printer May require external printer
    Housing SUS 316L stainless steel Material varies by model
    Wireless and Audit Functions Optional advanced functions available Depends on model
    Typical Use High-flow cleanroom and GMP monitoring General airborne particle measurement
     


    Frequently Asked Questions
    1. What is the LPC-5100 used for?
    The LPC-5100 is used to measure airborne particles in cleanrooms and controlled environments. It is suitable for pharmaceutical, medical, electronics, food, cosmetics, aerospace and other industries.
    2. What is the sampling flow rate of the LPC-5100?
    The standard sampling flow rate is 100 L/min, equivalent to 3.53 CFM.
    3. Which particle sizes can the LPC-5100 measure?
    The standard instrument simultaneously displays six particle-size channels: 0.5, 0.7, 1.0, 3.0, 5.0 and 10.0 μm. A 25 μm channel is available as an option.
    4. Does the LPC-5100 support GMP cleanroom classification?
    Yes. The instrument supports static and dynamic measurements for GMP A, B, C and D grades and can automatically determine cleanliness levels according to the selected standard.
    5. Can the LPC-5100 calculate UCL values?
    Yes. The LPC-5100 supports UCL calculation and can display and print measured values, calculated values, UCL values and cleanliness-level results.
    6. How much data can the instrument store?
    It can store at least 20,000 single-measurement records or 10,000 UCL records. Data can also be exported through the USB interface.
    7. Does the instrument have a built-in printer?
    Yes. The LPC-5100 is equipped with a built-in thermal printer. Users can select the particle-size channels to be printed and print reports with one key.
    8. How long can the battery operate?
    The built-in 16.8V lithium battery provides approximately 4 hours of operating time, depending on operating conditions.
    9. Does the LPC-5100 support temperature and humidity measurement?
    Temperature and humidity measurement is available as an optional function. The optional probe measures −40°C to +123.8°C and 0–100% RH.


  • Frequently Asked Questions
    1. What is the LPC-5100 used for?
    The LPC-5100 is used to measure airborne particles in cleanrooms and controlled environments. It is suitable for pharmaceutical, medical, electronics, food, cosmetics, aerospace and other industries.
    2. What is the sampling flow rate of the LPC-5100?
    The standard sampling flow rate is 100 L/min, equivalent to 3.53 CFM.
    3. Which particle sizes can the LPC-5100 measure?
    The standard instrument simultaneously displays six particle-size channels: 0.5, 0.7, 1.0, 3.0, 5.0 and 10.0 μm. A 25 μm channel is available as an option.
    4. Does the LPC-5100 support GMP cleanroom classification?
    Yes. The instrument supports static and dynamic measurements for GMP A, B, C and D grades and can automatically determine cleanliness levels according to the selected standard.
    5. Can the LPC-5100 calculate UCL values?
    Yes. The LPC-5100 supports UCL calculation and can display and print measured values, calculated values, UCL values and cleanliness-level results.
    6. How much data can the instrument store?
    It can store at least 20,000 single-measurement records or 10,000 UCL records. Data can also be exported through the USB interface.
    7. Does the instrument have a built-in printer?
    Yes. The LPC-5100 is equipped with a built-in thermal printer. Users can select the particle-size channels to be printed and print reports with one key.
    8. How long can the battery operate?
    The built-in 16.8V lithium battery provides approximately 4 hours of operating time, depending on operating conditions.
    9. Does the LPC-5100 support temperature and humidity measurement?
    Temperature and humidity measurement is available as an optional function. The optional probe measures −40°C to +123.8°C and 0–100% RH.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com