Position: Home > > Lab general equipment > Cleaning / disinfection equipment > Glove box > Lab2000 Inert Gas Glove Box

Lab2000 Inert Gas Glove Box

Product ID:SYQXXDsht031

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberLab2000
    Brand NameYITEKESI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    Lab2000 Inert Gas Glove Box
    Product Introduction
    Lab2000 inert gas glove box is a high-performance vacuum glovebox system designed for moisture-sensitive and oxygen-sensitive experiments in materials science, battery research, semiconductor manufacturing, nanomaterial preparation, and advanced chemical research.
    The system provides a highly purified inert atmosphere with water and oxygen concentrations maintained below 1 ppm, enabling researchers to perform sensitive operations under controlled low-moisture and oxygen-free conditions. Equipped with advanced purification materials from Germany BASF and the United States UOP, Siemens intelligent control technology, and automatic regeneration functions, the Lab2000 glove box ensures stable long-term operation and reliable experimental protection.
    The front-opening transparent window design improves visibility and operational convenience, making it an ideal solution for high-purity material preparation and research applications.

     

    Key Features
    • Ultra-high purity inert atmosphere
    Maintains H₂O ≤1 ppm and O₂ ≤1 ppm inside the glove box, providing a stable oxygen-free and moisture-free environment for sensitive experiments.
    • Advanced purification technology
    Uses German BASF oxygen removal materials and UOP high-efficiency moisture adsorption materials to achieve continuous purification performance.
    • Intelligent automatic control system
    Equipped with Siemens microcontroller and 7-inch color touchscreen interface for monitoring and controlling:
    • Gas pressure regulation
    • Purification status
    • Regeneration process
    • System parameters
    • Operating conditions
    • Alarm and safety functions
    • Front-opening transparent window design
    The ergonomic front window provides excellent visibility, easier sample handling, and improved user experience.
    • Automatic regeneration system
    Fully automatic valve control enables safe and reliable purification regeneration without complicated manual operation.
    • High-performance vacuum system
    Supports reliable vacuum operation with Atlas GVD-12 or Edwards RV12 vacuum pumps.
    • Efficient circulation purification
    High-speed variable-frequency circulation fan provides adjustable airflow from 0–100 m³/h with microprocessor control.
    • High safety and contamination control
    Integrated HEPA filtration system with 0.3 μm high-efficiency filter ensures clean internal circulation.

     

    Working Principle
    The Lab2000 inert gas glove box operates by creating a controlled inert atmosphere through continuous gas purification and circulation.
    The system first removes oxygen and moisture from the internal atmosphere using dedicated purification columns containing oxygen removal materials and moisture adsorption materials. The purified inert gas continuously circulates inside the glove box through a closed-loop system.
    During operation:
    The vacuum pump removes residual gases and moisture from the chamber.
    Purification columns eliminate oxygen and water vapor.
    The circulation fan maintains uniform gas distribution.
    Sensors monitor oxygen, moisture, pressure, and system conditions.
    Automatic control modules regulate purification, regeneration, and safety functions.
    This process maintains a stable ultra-clean environment suitable for sensitive materials processing.

     

    Technical Specifications
    Parameter Specification
    Oxygen concentration ≤1 ppm
    Water concentration ≤1 ppm
    Leakage rate ≤0.01 vol%/h
    Main chamber size 1200 × 750 × 900 mm (L × W × H)
    Front window Openable transparent glass window
    Glove ports 2 ports
    Glove port material Hard aluminum alloy / POM
    Gloves North USA butyl rubber gloves
    Glove diameter 8 inches
    Glove thickness 0.4 mm
    Large antechamber Ø360 mm × L600 mm
    Large antechamber vacuum ≤ -0.1 MPa
    Small antechamber Ø150 mm × L330 mm
    Small antechamber vacuum ≤ -0.1 MPa
    Control system Siemens microcontroller
    Touchscreen Siemens 7-inch color touchscreen
    Operation interface Chinese human-machine interface
    Regeneration control Fully automatic valve control
    Vacuum pump options Atlas GVD-12 / Edwards RV12
    Circulation airflow 0–100 m³/h
    Circulation fan Variable-frequency high-speed fan
    Oxygen purification material BASF oxygen removal material
    Moisture purification material UOP high-efficiency adsorption material
    Purification valve Bürkert automatic pneumatic valve
    Filter HEPA standard 0.3 μm filter
    Solvent purification Activated carbon solvent adsorption column
     

    Main Components
    1. Purification System
    The purification system adopts high-performance oxygen and moisture removal materials:
    • German BASF oxygen purification material
    • American UOP moisture adsorption material
    • Automatic regeneration capability
    • Long-term stable purification performance
    The system maintains ultra-low oxygen and moisture levels for demanding research environments.

     

    2. Control System
    The Siemens intelligent control platform provides:
    • Touchscreen operation
    • Real-time system monitoring
    • Automatic pressure control
    • Purification status display
    • Fault alarms
    • Operating parameter recording
    The intuitive interface simplifies daily operation and maintenance.

     

    3. Vacuum Antechamber System
    The glove box includes:
    • Large transfer chamber for larger samples
    • Small transfer chamber for routine sample transfer
    • Independent vacuum control
    • Rapid material transfer without atmospheric contamination

     

    Applications
    Battery Material Research
    Suitable for:
    • Lithium-ion battery electrode preparation
    • Solid-state battery research
    • Battery electrolyte handling
    • Air-sensitive material processing
    Nanomaterial Preparation
    Used for:
    • Nanoparticle synthesis
    • Metal nanomaterial preparation
    • Air-sensitive chemical reactions
    Semiconductor Research
    Applications include:
    • Semiconductor material processing
    • Wafer handling
    • Oxygen-sensitive experiments
    Chemical Research
    Suitable for:
    • Organic synthesis
    • Catalyst preparation
    • Reactive chemical experiments

     

    Advantages Compared with Conventional Glove Boxes
    Feature Lab2000 Inert Gas Glove Box Conventional Glove Box
    Oxygen level ≤1 ppm Higher fluctuation
    Moisture level ≤1 ppm Limited control
    Purification system BASF + UOP advanced materials Standard purification materials
    Control system Siemens touchscreen automation Manual or basic control
    Regeneration Fully automatic Manual operation required
    Application range Battery, semiconductor, nanomaterials General laboratory use
    Safety monitoring Integrated alarms and monitoring Limited functions
     

    FAQ
    1. What is the Lab2000 inert gas glove box used for?
    The Lab2000 glove box is mainly used for experiments requiring oxygen-free and moisture-free environments, including battery materials, nanomaterials, semiconductor research, and chemical synthesis.
    2. What oxygen and moisture levels can the glove box achieve?
    The system can maintain oxygen concentration and water concentration below 1 ppm, providing a highly purified inert atmosphere.
    3. Which gases can be used inside the glove box?
    The glove box is typically operated with inert gases such as nitrogen or argon, depending on the experimental requirements.
    4. Why choose a front-opening window glove box?
    The front-opening transparent window improves visibility, provides easier access to samples, and enhances operator convenience during experiments.
    5. Does the Lab2000 glove box require frequent regeneration?
    No. The system features automatic regeneration control, reducing manual operation and improving long-term stability.
    6. Is this glove box suitable for lithium battery research?
    Yes. The Lab2000 is widely suitable for lithium battery electrode preparation, electrolyte handling, and other moisture-sensitive battery material experiments.
    7. What factors should be considered when purchasing a glove box?
    Users should consider:
    • Required oxygen and moisture purity levels
    • Chamber size requirements
    • Transfer chamber capacity
    • Control automation level
    • Application environment
    • Purification and regeneration technology

     

    Product Summary
    The Lab2000 Inert Gas Glove Box with Front Opening Window is an advanced laboratory glovebox system designed for ultra-clean inert atmosphere applications. With ≤1 ppm oxygen and moisture control, intelligent Siemens automation, advanced BASF/UOP purification technology, and reliable vacuum transfer systems, it provides a professional solution for battery research, semiconductor processing, nanomaterial preparation, and advanced chemical experiments.

     

     
     
  • FAQ
    1. What is the Lab2000 inert gas glove box used for?
    The Lab2000 glove box is mainly used for experiments requiring oxygen-free and moisture-free environments, including battery materials, nanomaterials, semiconductor research, and chemical synthesis.
    2. What oxygen and moisture levels can the glove box achieve?
    The system can maintain oxygen concentration and water concentration below 1 ppm, providing a highly purified inert atmosphere.
    3. Which gases can be used inside the glove box?
    The glove box is typically operated with inert gases such as nitrogen or argon, depending on the experimental requirements.
    4. Why choose a front-opening window glove box?
    The front-opening transparent window improves visibility, provides easier access to samples, and enhances operator convenience during experiments.
    5. Does the Lab2000 glove box require frequent regeneration?
    No. The system features automatic regeneration control, reducing manual operation and improving long-term stability.
    6. Is this glove box suitable for lithium battery research?
    Yes. The Lab2000 is widely suitable for lithium battery electrode preparation, electrolyte handling, and other moisture-sensitive battery material experiments.
    7. What factors should be considered when purchasing a glove box?
    Users should consider:
    • Required oxygen and moisture purity levels
    • Chamber size requirements
    • Transfer chamber capacity
    • Control automation level
    • Application environment
    • Purification and regeneration technology

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com