    Brief introduction:
    HW2000 - D type high frequency infrared multi-element analyzer can detect all kinds of metal and nonmetal materials in a variety of elements. Using the carbon, sulfur content, high frequency infrared absorption method and USES the photoelectric colorimetry to detect other elements.
    This equipment is a set of optical, mechanical and electrical, computer, analysis technology is one of the high-tech products, has a wide range of measurement and analysis results are accurate and reliable, etc. Adopt the most advanced computer technology, intelligent instrument, screen display of graph, text and data acquisition, processing and so on all has reached the domestic advanced level, are two industries determination of carbon and sulfur element analysis of the ideal equipment.
    Features:
    1. Autonomous directional coupler power feedback, guarantee the output power is consistent, make sample sufficient combustion, stability is good.
    2. Using high precision electronic flowmeter control analysis of gas flow, the results of the analysis is more stable and reliable;
    3.is made of cast aluminum integration forming furnace, gold processing, effectively prevent leakage phenomenon caused by assembly;
    4. The furnace automatic double helix is dust cleaning, three layers of baffle splash proof design, to improve the measurement accuracy;
    5. High pressure automatic function of dirt, dust exhausting channel dedicated, reduce gas road congestion; Developed by using powder metallurgy material dust filter, dust filter installed inside the furnace head, each analysis two automatic cleaning the combustion chamber and dust filter, and automatic vacuuming, prevent dust adsorption effect of the analysis process;
    6. Set up multiple filter in the gas path, ensure that use gas for time not contaminated;
    7. Silicone rubber or stainless steel gas path, good seal, for analysis of gas adsorption and catalysis, easy to achieve good stability;
    8. Imported 72 sample chips, 4 core processor, high speed and precision.
    9. Power supply: adopt high quality linear integration of the military level module power supply, output stability, trouble-free.
    10. The light of the light emission wavelength at source or is limited to 2-10 um, to ensure no stray light; Access to the subsequent testing, to ensure the stability and testing precision of the detection; Focusing device inside the light source, to ensure that the emergent light parallel; Light filled shielding gas, protect the light source is stable and anti-oxidation
    Technical parameters:
    Measuring range: this instrument can detect elements is more, in the conventional elements in steel, for example:
    Carbon: 0.00001% ~ 99.9999% sulfur: 0.00001% ~ 99.9999%
    Manganese: 0.010% ~ 70.000% phosphorus: 0.0005% ~ 1.0000%
    Si: 0.010% ~ 80.000% chrome: 0.010% ~ 85.000%
    Nickel: 0.005% ~ 85.000% molybdenum: 0.010% ~ 15.000%
    Re: 0.0100% ~ 0.0100% magnesium, 8.000% ~ 15.000%
    Titanium copper: 0.010% ~ 95.000%, 0.010% ~ 10.000%
    Analytical error: (all element analysis method in accordance with GB/T 223 standard, the following five elements, for example) have regular
    Carbon, sulfur IS09556 standard: IS04935 standards
    Silicon manganese: GB/T223.69-1988 standard: GB/T223.5-2008 standard
    P: GB/T223.59-2008 standard...
    Accuracy: meet ISO9556-94, the ISO4935-94, such as GB223.3 ~ 5-1988 standard
    Methods: carbon sulfur by high frequency infrared absorption method, other elements using photoelectric colorimetry.
    Precision: meet the national metrological verification procedures JJG395-97 standard
    Analysis time: 25 to 60 seconds is adjustable, generally in 35 seconds
    Sensitivity: 0.000001% (0.01 parts per million (PPM)
    Electronic balance: one over ten thousand; The accuracy of reading: 0.0001 g; Data automatic transmission
    High frequency furnace: high-power high-frequency air-cooled ceramic power tube; The oscillation frequency of 30 MHZ, maximum power can be up to 5 kw
    Infrared absorption pool: the double integration of carbon disulfide platinum absorption pool
    Photoelectric colorimetric system: a total of ten channel, each channel can store 30 work curve, in principle, a total of 300 elements can be detected.
     

  • Brief introduction:
    HW2000 - D type high frequency infrared multi-element analyzer can detect all kinds of metal and nonmetal materials in a variety of elements. Using the carbon, sulfur content, high frequency infrared absorption method and USES the photoelectric colorimetry to detect other elements.
    This equipment is a set of optical, mechanical and electrical, computer, analysis technology is one of the high-tech products, has a wide range of measurement and analysis results are accurate and reliable, etc. Adopt the most advanced computer technology, intelligent instrument, screen display of graph, text and data acquisition, processing and so on all has reached the domestic advanced level, are two industries determination of carbon and sulfur element analysis of the ideal equipment.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com