GC5890F gas chromatograph

Product ID:KSqi010

Price: US$6,000.00 ~ US$10,000.00 PDF Format
Supply Ability:20 sets/mon
Port:shenzhen
share:
  • Product Introduction
  • Consulting
  • Model NumberGC5890F
    Brand NameYIMA
    Payment TermsT/T, paypal
    Main features:
    1, fully compatible with HP HP5890II gas chromatograph, can be directly connects HP5890 miniature monofilament thermal conductivity detector, hydrogen flame ionization detector and correlation detector board. Instrument technical indexes and performance, the detector sensitivity is equivalent to that of HP5890!
    2, a new integrated digital electronic circuit, high control precision, stable and reliable performance, temperature control precision of 0.01 °C.
    3, unique design to solve the injection port sample discrimination; Double column not only solve the warming process drift compensation function, and subtracting the influence of background noise, can get a lower detection limit of the minimum.
    4, oven, large volume, intelligent and open system stepless variable in and out of the air flow rate, shorten the process l/after cooling system stable equilibrium time; Heating system (temperature ranges) + 7 °C ~ 400 °C environment temperature. The third order, temperature programmed heating rate 0 to 50 °C / min; Increment of 0.1 °C / min can be recalibrated furnace temperature by the user, and set the highest temperature at will. Heating furnace temperature balance time decided by user.
    5, can install two sample systems at the same time: the packed column, capillary shunt/no shunt injection system (with functions of membrane cleaning); Can be installed at the same time two kinds of the same or different detector: hydrogen flame ionization detector (FID), thermal conductivity detector (TCD). Can be equipped with automatic/manual gas six sample injection valve, air sampler, thermal desorption sampler, cracking furnace injector, methane conversion furnace.
    6, the detector system: flame ion detector is easy to remove and install, easy to clean or replace the nozzle; Thermal conductivity detector of high value single high detection sensitivity and baseline quickly stable (15 minutes); Input signals can be logarithmic amplifier, reduce interference, improve sensitivity. Optional, TCD, ECD, NPD and FPD.
    7, have boot self-diagnosis function, stopwatch function (convenient traffic), timer function operation, power storage protection function, and key lock function.
    Technical indicators
    Temperature control detector FID
    Temperature range : room temperature on 7 °C -400 °C ( increments of 0.1 °C)
    Programming phase : third-order
    Programming rate : 0.1 
    °C -50 °C / min ( increments of 0.1 °C)

     
    Detection limit : ≤ 5 × 10-12g / s ( n-hexadecane )
    Baseline noise : ≤ 6 × 10-12A / H
    Linear range : ≥ 105
    Stabilization time : less than 20min

     
    detector TCD detector FPD
    Sensitivity : ≥ 10000mV · ml / mg ( n-hexadecane )
    Baseline Noise : ≤ 30uV ( hydrogen carrier gas was 99.999 )

     
    Detection limit : ≤ 5 × 10-12g / s (N)
    Baseline noise : ≤ 2 × 10-13A / H

     
    detector ECD detector NPD
    Detection limit : ≤ 5 × 10-12g / s (N) (r-666)
    Baseline noise : ≤ 2 × 10-13A / H

     
    Detection limit : ≤ 5 × 10-12g / s (N)
    Baseline noise : ≤ 2 × 10-13A / H
     
  • Brief introduction
          The newly designed GC126 gas chromatograph , using the international advanced control technology . High temperature accuracy ( better than ± 0.1 ℃) superior reliability and robustness. Control and use the keyboard to set the various parameters , the machine has a self- diagnosis , power protection , file storage and call , extreme temperature setting and other functions. 3.8 " large screen can accurately display the brightest temperature setpoint, actual value and real-time curve , each detector parameters , the signal value and its real-time curve . Control area has six independent : the oven , injector , detector, aids . The product can achieve nine bands temperature program , after the oven has automatic cooling function that is open to achieve rapid heating and rapid cooling . Instrument base with a double and a single type of high sensitivity hydrogen flame ionization detector (FID), one of the following optional detectors, gas sampling valve , reformer and other accessories can also install two detectors and detection high sensitivity ( e.g. FID test results for : DFID≤4 × 10-12g / s), the settling time is short, easy cleaning and nozzle mounting

Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com