Position: Home > > Analytical instruments > Electrochemistry > ORP measuring instrument > FJA-6 ORP depolarization method automatic measuring system for Water quality testing

FJA-6 ORP depolarization method automatic measuring system for Water quality testing

Product ID:FDorp003

Price: Please inquire PDF Format
Supply Ability:220SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberFJA-6
    Brand NameYIMA
    Payment TermsT/T, paypal
    Brief introduction:
    Redox potential (Eh) as the media ( including soil , natural water , media , etc. ) of a comprehensive indicator of environmental conditions , has been used for a long time, it is characterized by the media relative degree of oxidation or reduction . For a long time the redox potential is the use of a platinum electrode direct assay. Upcoming platinum electrode and a reference electrode directly into the medium was measured . However, when measuring weak balance system , due to the inert platinum electrode is not absolute , the surface oxide film may be formed or adsorb other substances . Influence of the redox couple on a platinum electrode electronic exchange rate , thus establishing equilibrium potential is extremely slow , and in some medium, subject to a few hours or even a day or two , and the measurement error is very large, usually 40-100mV. If the full account of the dynamics of the surface properties of the platinum electrode and the electrode potential established , complex medium , if determined by the redox potential depolarization method , more accurate results can be obtained in a short time of 2 minutes , usually less than 10mV or better.
     Main features:
    1 , measurement item ORP, pH and temperature measurement , can be measured one by one , three parameters can be measured simultaneously ( when used in combination with the PC ) .
    2 , MCU and PC compatible ( can also be used in the field independently associated with PC use )
    3, through the USB port and PC combined.
    4 can be used with a PC or laptop in conjunction with, the entire process is done automatically measurement and data processing under program control , in addition it can automatically draw the curve and the results are automatically saved, it can be selected based on a single measurement or data acquisition cycle .
    5. Determination of the conventional measurement methods, the use of positive and negative measured depolarization method.

    6 , better fidelity . Measurement result is the end result , rather than the traditional method of periodic results .
    7 , to shorten the measurement time .
    8 , measurement and data processing all automatically.
    9 , the reference electrode potential look-up table is automatically determined by the temperature
    10 , higher instrument integration, smaller, more feature-full . 

    Technical parameters:
    1, measuring range: 0 to + -1999.9mV; minimum reading for 0.1mV
    2, ORP measurement accuracy: less than 10mV
    3, the input impedance: > 10 th European 10
    4 , to complete a measure of the minimum time : 2 minutes
    5. Power 8.4V lithium battery

     

  • Brief introduction:
    Redox potential (Eh) as the media ( including soil , natural water , media , etc. ) of a comprehensive indicator of environmental conditions , has been used for a long time, it is characterized by the media relative degree of oxidation or reduction . For a long time the redox potential is the use of a platinum electrode direct assay. Upcoming platinum electrode and a reference electrode directly into the medium was measured . However, when measuring weak balance system , due to the inert platinum electrode is not absolute , the surface oxide film may be formed or adsorb other substances . Influence of the redox couple on a platinum electrode electronic exchange rate , thus establishing equilibrium potential is extremely slow , and in some medium, subject to a few hours or even a day or two , and the measurement error is very large, usually 40-100mV. If the full account of the dynamics of the surface properties of the platinum electrode and the electrode potential established , complex medium , if determined by the redox potential depolarization method , more accurate results can be obtained in a short time of 2 minutes , usually less than 10mV or better.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com