  • Model NumberFJA-04
    Brand NameNJCHUANDI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    FJA-04 Automatic Titrator
    Product Introduction
    The FJA-04 Automatic Titrator is an integrated, multifunctional automatic titration instrument designed for independent operation in analytical laboratories. It supports various titration methods, including acid-base neutralization, redox, precipitation, and complexometric titration.
    With eight analytical functions, automated reagent delivery, endpoint detection, and convenient menu-based operation, the FJA-04 provides a versatile solution for laboratory chemical analysis, quality control, and research applications.

     

    Performance Features
    1.Multifunctional Titration: Supports eight titration modes, including potentiometric, pH, Karl Fischer, amperometric, and photometric titration, as well as Gran plot analysis.
    2. Automated Operation: The burette system automatically performs liquid dispensing, reagent refilling, valve switching, and dead-volume compensation.
    3. Intelligent Endpoint Detection: Pre-titration functions allow the instrument to learn endpoint conditions, reducing uncertainty associated with manual endpoint parameter settings.
    4. User-Friendly Interface: Features an LCD display, menu-based operation, and printer output for convenient result recording.
    5. Flexible Parameter Configuration: Titration method parameters can be configured through interactive operation, with previous settings automatically restored when the instrument is restarted.
    6. High-Precision Signal Acquisition: Uses a high-input-impedance amplifier for potentiometric measurements, with a minimum signal reading of 0.1 mV.
    7.  Adjustable Dispensing Accuracy: Users can calibrate and adjust dispensing volume through the titration proportional coefficient.

     

    Working Principle
    The FJA-04 Automatic Titrator operates by automatically delivering titrant into a sample while monitoring changes in the corresponding analytical signal, such as electrode potential, pH, current, or light intensity.
    Depending on the selected titration method, the instrument identifies the endpoint through constant-current, preset differential, potentiometric, or photometric detection principles. Its pre-titration function helps establish suitable endpoint conditions before formal analysis.
    The automatic burette system controls reagent dispensing, refilling, valve switching, and volume accumulation, enabling consistent and efficient titration procedures.

     

    Titration Functions
    Function Abbreviation Description
    Dead-Stop Endpoint Potentiometric Titration VDT Detects the titration endpoint using a dead-stop potentiometric method
    Preset Differential Endpoint Potentiometric Titration VPT Identifies endpoints using preset differential potential conditions
    Preset Differential Endpoint pH Titration pHPT Determines endpoints through pH signal changes
    Karl Fischer Titration KFT Supports water content determination
    Dead-Stop Endpoint Amperometric Titration CDT Detects endpoints through current measurement
    Preset Differential Endpoint Photometric Titration PPT Uses optical or colorimetric signal changes
    Dead-Stop Endpoint Photometric Titration PDT Determines endpoints using photometric detection
    Gran Plot Method GP Supports both addition-based and titration-based Gran plot analysis
    Technical Parameters
    Parameter Specification
    Titration Modes 8 modes
    Titration Applications Acid-base, redox, precipitation, and complexometric titration
    Burette Operation Automatic dispensing and refilling
    Valve Control Automatic valve switching
    Volume Compensation Automatic dead-volume compensation
    Minimum Dispensing Volume 0.01 mL
    Titration Volume Calculation Automatic cumulative volume calculation
    Dispensing Volume Calibration Adjustable through titration proportional coefficient
    Potentiometric Signal Input High-impedance amplifier
    Input Impedance 10¹² Ω
    Minimum Signal Reading 0.1 mV
    Display LCD
    Operation Menu-based operation
    Data Output Printer output
    Parameter Memory Automatically restores previous settings
     

    Application Scenarios
    • Chemical Analysis Laboratories: Acid-base, redox, precipitation, and complexometric analysis.
    • Pharmaceutical Industry: Water content determination using Karl Fischer titration and other analytical procedures.
    •  Chemical Manufacturing: Raw material testing, process quality control, and chemical concentration analysis.
    •  Food and Beverage Testing: Acid-base analysis and other titrimetric quality assessments.
    •  Environmental Laboratories: Chemical analysis of water and environmental samples.
    •   Scientific Research: Versatile potentiometric, amperometric, and photometric titration experiments.

     

    Comparison: FJA-04 Automatic Titrator vs. Conventional Manual Titration
    Feature FJA-04 Automatic Titrator Conventional Manual Titration
    Reagent Dispensing Automatic Manual
    Endpoint Detection Multiple automatic detection methods Usually visual or manual
    Titration Methods 8 integrated functions Depends on equipment
    Volume Calculation Automatic accumulation Manual recording and calculation
    Endpoint Optimization Pre-titration learning function Manual adjustment
    Data Display LCD display Visual observation or external instruments
    Result Printing Printer output Usually requires manual documentation
    Operation Menu-based automated control Operator-dependent
     

    Frequently Asked Questions (FAQ)
    Q1: What is the FJA-04 automatic titrator used for?
    The FJA-04 is used for laboratory chemical analysis, including acid-base, redox, precipitation, and complexometric titration.
    Q2: How many titration methods does the FJA-04 support?
    It supports eight functions: VDT, VPT, pHPT, KFT, CDT, PPT, PDT, and Gran plot analysis (GP).
    Q3: Does the FJA-04 support Karl Fischer titration?
    Yes. Its KFT function supports Karl Fischer titration for water content determination.
    Q4: Does the instrument automatically dispense and refill reagents?
    Yes. Its automatic burette system handles reagent dispensing, refilling, valve switching, and dead-volume compensation.
    Q5: What is the minimum dispensing volume?
    The minimum dispensing volume is 0.01 mL, and the delivered volume is automatically accumulated.
    Q6: How does the FJA-04 improve endpoint detection?
    Its pre-titration function allows the instrument to learn endpoint conditions, helping reduce uncertainty when setting endpoint parameters manually.
    Q7: What is the input impedance of the potentiometric measurement system?
    The potentiometric signal input uses a high-impedance amplifier with an input impedance of 10¹² Ω.
    Q8: Can the FJA-04 print titration results?
    Yes. The instrument supports printer output for convenient recording and documentation of analytical results.

     
     

     
  • Frequently Asked Questions (FAQ)
    Q1: What is the FJA-04 automatic titrator used for?
    The FJA-04 is used for laboratory chemical analysis, including acid-base, redox, precipitation, and complexometric titration.
    Q2: How many titration methods does the FJA-04 support?
    It supports eight functions: VDT, VPT, pHPT, KFT, CDT, PPT, PDT, and Gran plot analysis (GP).
    Q3: Does the FJA-04 support Karl Fischer titration?
    Yes. Its KFT function supports Karl Fischer titration for water content determination.
    Q4: Does the instrument automatically dispense and refill reagents?
    Yes. Its automatic burette system handles reagent dispensing, refilling, valve switching, and dead-volume compensation.
    Q5: What is the minimum dispensing volume?
    The minimum dispensing volume is 0.01 mL, and the delivered volume is automatically accumulated.
    Q6: How does the FJA-04 improve endpoint detection?
    Its pre-titration function allows the instrument to learn endpoint conditions, helping reduce uncertainty when setting endpoint parameters manually.
    Q7: What is the input impedance of the potentiometric measurement system?
    The potentiometric signal input uses a high-impedance amplifier with an input impedance of 10¹² Ω.
    Q8: Can the FJA-04 print titration results?
    Yes. The instrument supports printer output for convenient recording and documentation of analytical results.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com