Position: Home > > Analytical instruments > Elemental Analyzer > Mercury measuring instrument > ETCG-2A Microcomputer Mercury Detector

ETCG-2A Microcomputer Mercury Detector

Product ID:FYcg004

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberETCG-2A
    Brand NameJTYITONG
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    ETCG-2A Microcomputer Mercury Detector
    Product Introduction
    The ETCG-2A Microcomputer Mercury Detector is an intelligent mercury analysis instrument designed for rapid and accurate determination of mercury content in various samples. Based on cold atomic absorption spectroscopy (CAAS) technology, the instrument detects elemental mercury vapor at room temperature without heating and measures mercury concentration through ultraviolet absorption at 253.7nm.
    Equipped with an advanced microcomputer control system, imported sensor, color touchscreen interface, automatic calibration curve storage, and data management functions, the ETCG-2A Mercury Analyzer provides simple operation, high reliability, and direct concentration readings.
    The instrument is widely used for mercury detection in water, air, soil, food, cosmetics, chemical materials, environmental monitoring, sanitation, and industrial laboratories.

     

    Performance Features
    Cold Atomic Absorption Mercury Detection Technology
    •  Uses cold atomic absorption method for mercury measurement.
    •  No heating process required during detection.
    •  Provides direct mercury concentration measurement.
    Intelligent Microcomputer Control
    •  Built-in MCU processing system.
    •  Automatically calculates mercury concentration.
    •  Displays measurement results directly without manual conversion.
    High Sensitivity Mercury Analysis
    •  Uses imported high-performance sensors.
    •  Provides excellent detection stability.
    •  Detection limit reaches 0.02ng/ml.
    Easy Touchscreen Operation
    •  Large color touchscreen display.
    •  Simple interface for convenient operation.
    •  Suitable for laboratory and field testing applications.
    Automatic Calibration and Data Storage
    •  Built-in mercury standard curve.
    •  Supports user calibration and automatic storage.
    •  Stores up to 256 measurement records.
    Efficient Data Management
    •  Supports data query by value, date, and measurement time.
    •  USB communication interface allows data transfer, printing, and saving.
    Real-Time Environmental Monitoring
    •  Displays mercury concentration, temperature, and humidity simultaneously.

     

    Working Principle
    The ETCG-2A Microcomputer Mercury Detector operates based on the principle of cold atomic absorption spectroscopy.
    Mercury compounds in the sample are converted into elemental mercury vapor under room temperature conditions. The generated mercury vapor absorbs ultraviolet light at a characteristic wavelength of 253.7nm.
    Within a specific concentration range, the absorption intensity is proportional to the mercury concentration according to the Beer-Lambert law. The detector measures the ultraviolet absorption signal and the microcomputer system automatically calculates and displays the mercury concentration.
    This method provides direct mercury measurement without complex calculations, offering fast, accurate, and reliable analysis.

     

    Technical Parameters
    Category Parameter
    Product Model ETCG-2A Microcomputer Mercury Detector
    Measurement Principle Cold Atomic Absorption Method
    Detection Element Mercury (Hg)
    UV Detection Wavelength 253.7nm
    Measuring Range 0–10ng/ml
    Extended Range Higher concentration measurable after dilution
    Detection Limit 0.02ng/ml
    Linear Correlation Coefficient R ≥0.995
    Flow Adjustment Range 0–2.5L/min
    Display Function Mercury concentration, temperature, humidity
    Operation Interface Color touchscreen
    Calibration Function Built-in standard curve, user calibration supported
    Data Storage Capacity 256 groups
    Data Query Value, date, measurement time
    Communication Interface USB
    Power Supply 220V ±10%
    Instrument Dimensions 410 × 400 × 400mm³
    Operating Temperature 0–40℃
     

    Application Scenarios
    Environmental Monitoring
    Used for mercury detection in water, soil, and air samples to support environmental quality assessment.
    Food Safety Testing
    Suitable for mercury residue analysis in food products and agricultural samples.
    Chemical Industry
    Used for mercury content measurement in chemical raw materials and industrial samples.
    Cosmetics Testing
    Supports safety evaluation through mercury contamination analysis.
    Public Health and Sanitation
    Applied in health inspection and epidemic prevention laboratories.
    Research Laboratories
    Suitable for universities, testing centers, and analytical laboratories requiring trace mercury detection.

     

    ETCG-2A Mercury Detector vs Traditional Mercury Testing Equipment
    Feature ETCG-2A Microcomputer Mercury Detector Traditional Mercury Analyzer
    Detection Method Cold atomic absorption Various chemical or manual methods
    Operation Touchscreen intelligent operation More complex manual operation
    Result Calculation Automatic concentration calculation Manual conversion often required
    Data Storage 256 measurement records Limited or no storage
    Calibration Automatic standard curve storage Manual calibration procedures
    Detection Limit 0.02ng/ml Usually higher
    Data Transfer USB communication Limited data management
    Application Efficiency Fast and convenient More time-consuming
    The ETCG-2A Mercury Detector improves mercury analysis efficiency through intelligent control, automatic calculation, and digital data management compared with traditional mercury testing methods.
     

    Frequently Asked Questions (FAQ)
    1. What is the ETCG-2A Microcomputer Mercury Detector used for?
    The ETCG-2A is used for measuring mercury content in water, air, soil, food, cosmetics, chemical materials, and environmental samples.
    2. What detection method does the ETCG-2A use?
    It uses cold atomic absorption spectroscopy technology based on mercury vapor absorption at 253.7nm ultraviolet wavelength.
    3. Does the ETCG-2A require sample heating?
    No. The cold atomic absorption method detects mercury vapor under room temperature conditions without heating.
    4. What is the measuring range of the ETCG-2A?
    The standard measuring range is 0–10ng/ml. Higher concentrations can be measured after sample dilution.
    5. What is the detection limit of this mercury analyzer?
    The detection limit is 0.02ng/ml.
    6. How many measurement records can the instrument store?
    The ETCG-2A can automatically store up to 256 groups of measurement data.
    7. Can measurement data be transferred to a computer?
    Yes. The instrument provides a USB communication interface for data import, saving, and printing.
    8. Is calibration required before measurement?
    The instrument includes a built-in mercury standard curve and supports user calibration when required.

     

    Product Summary
    The ETCG-2A Microcomputer Mercury Detector is a high-performance cold atomic absorption mercury analyzer designed for accurate trace mercury measurement. With 253.7nm UV detection technology, intelligent MCU control, automatic calculation, touchscreen operation, data storage, and USB communication, it provides an efficient solution for mercury analysis in environmental monitoring, food safety, chemical testing, and laboratory research.

     
     


     
  • Frequently Asked Questions (FAQ)
    1. What is the ETCG-2A Microcomputer Mercury Detector used for?
    The ETCG-2A is used for measuring mercury content in water, air, soil, food, cosmetics, chemical materials, and environmental samples.
    2. What detection method does the ETCG-2A use?
    It uses cold atomic absorption spectroscopy technology based on mercury vapor absorption at 253.7nm ultraviolet wavelength.
    3. Does the ETCG-2A require sample heating?
    No. The cold atomic absorption method detects mercury vapor under room temperature conditions without heating.
    4. What is the measuring range of the ETCG-2A?
    The standard measuring range is 0–10ng/ml. Higher concentrations can be measured after sample dilution.
    5. What is the detection limit of this mercury analyzer?
    The detection limit is 0.02ng/ml.
    6. How many measurement records can the instrument store?
    The ETCG-2A can automatically store up to 256 groups of measurement data.
    7. Can measurement data be transferred to a computer?
    Yes. The instrument provides a USB communication interface for data import, saving, and printing.
    8. Is calibration required before measurement?
    The instrument includes a built-in mercury standard curve and supports user calibration when required.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com