DZY-001Z Automatic Open Flash Point Tester Introduction
DZY-001Z automatic opening flash point tester is designed with a large-scale control core combined with a liquid crystal display system. DZY-001Z automatic open flash point tester is used to measure petroleum products with open cup flash point higher than 79 ℃, except for fuel oil (fuel oil is usually measured according to GB / T 261).
The test process of this instrument adopts a fully automatic management method. The parameters such as temperature and time are displayed by a 240 * 128 dot matrix blue backlight LCD display. On this LCD display, users will also see the instrument at the same time. Working status and related operation tips. You only need to preset the expected flash point of the substance to be measured, and the instrument will start to heat up at the prescribed rate, and then perform ignition, flash point detection, detection device upgrade, air cooling, printout results, and other complex operations that have to be performed by yourself; You entered the local atmospheric pressure in advance, and the instrument will automatically correct the test results based on your input.
This instrument has powerful data processing functions: it can memorize the past 100 analysis results to facilitate your query and printing of historical records. Can remember the preset parameters before each shutdown. Technical parameters
Working power: AC220V ± 10% 50Hz standard 10A plug
Range: room temperature to 400 ° C
Flame diameter: 4mm
Detection method: PT100, measurement accuracy: 0.1 ℃
Display: full color touch display
Dimensions: 400 × 330 × 370 (mm)
Introduction
DZY-001Z automatic opening flash point tester is designed with a large-scale control core combined with a liquid crystal display system. DZY-001Z automatic open flash point tester is used to measure petroleum products with open cup flash point higher than 79 ℃, except for fuel oil (fuel oil is usually measured according to GB / T 261).
The test process of this instrument adopts a fully automatic management method. The parameters such as temperature and time are displayed by a 240 * 128 dot matrix blue backlight LCD display. On this LCD display, users will also see the instrument at the same time. Working status and related operation tips. You only need to preset the expected flash point of the substance to be measured, and the instrument will start to heat up at the prescribed rate, and then perform ignition, flash point detection, detection device upgrade, air cooling, printout results, and other complex operations that have to be performed by yourself; You entered the local atmospheric pressure in advance, and the instrument will automatically correct the test results based on your input.
This instrument has powerful data processing functions: it can memorize the past 100 analysis results to facilitate your query and printing of historical records. Can remember the preset parameters before each shutdown.