DS-3B Trace element analyzer

Product ID:SHLCwys 002

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberDS-3B
    Brand NameYM
    Payment TermsT/T, paypal
    Brief introduction
      A trace element according to the different needs of the user groups designed analyzer. Some users are more determined detection range . Only for zinc copper and iron , calcium and magnesium five elements, but the instrument calling for lower prices and consumption costs . DS-3B trace element analyzer main set for these users .
    Features
    1. Samples categories: whole blood (20 microlitre) or hair (0.1 grams).
    2. The test items: conventional zinc, copper, iron, calcium, magnesium, can add project according to customer's demand.
    3. The technical features: trace element detector adopts single electrode (static mercury electrode) system, polarography measuring blood zinc in accord with the ministry of health inspection procedures, etc. Less dosage of samples, less reagent consumption and low detection cost. Calibration instrument with whole blood standard substances, results are accurate, instrument repeatability, stable performance, high reliability results.
    4. Use the unit under the county hospital, maternal and child health care, in towns and townships, community hospitals and clinics.
    5. The instrument features: low prices, superior performance and beautiful appearance, especially suitable for small medical institutions. 
    Technical parameters
    1, electrode equipped:
    (1) static mercury electrode
    (2) glassy carbon electrode
    2, analysis method and function:
    (1) potential function
    (2) voltammetric function
    (3) potential dissolution
    (4) stripping voltammetry
    3, application range: whole blood (or hair) of zinc, iron, copper, calcium, magnesium, lead detection
    4, detection limit: 0.1 g / L (take the lead as an example)
    5, the coefficient of variation: RSD = 5%
    6, the correlation coefficient: 0.99
    7, the relative deviation of the calibration curve: less than 10% (to lead as an example)
    8, resistance to the first reduction ability: 5000:1
    9, detection method: lead to differential potentiometric stripping

     
  •  A trace element according to the different needs of the user groups designed analyzer. Some users are more determined detection range . Only for zinc copper and iron , calcium and magnesium five elements, but the instrument calling for lower prices and consumption costs . DS-3B trace element analyzer main set for these users .
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com