Position: Home > > Analytical instruments > X-ray instrument > X fluorescence spectrometer > DM2400 Monochrome Excitation Energy Dispersion X-ray Fluorescence Light Element Spectrometer

DM2400 Monochrome Excitation Energy Dispersion X-ray Fluorescence Light Element Spectrometer

Product ID:FXyg035

Price: Please inquire PDF Format
Supply Ability:90 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberDM2400
    Brand NameSHANGHAIAISITE
    Payment TermsT/T, paypal
    DM2400 Monochrome Excitation Energy Dispersion X-ray Fluorescence Light Element Spectrometer
    Introduction
    DM2400 monochromatic excitation energy dispersive X-ray fluorescence light element (Si, P, S, Cl) spectrometer, referred to as DM2400 MEDXRF light element spectrometer, is the company's research experience for decades of X-ray fluorescence spectrometer, in the company's original Based on DM series X-ray fluorescence analyzer, X-ray fluorescence multi-element analyzer, wavelength-dispersive X-ray fluorescence multi-channel spectrometer, etc., an XRF spectrometer that has reached the international advanced level has been developed. It uses the following technologies and devices to make the DM2400 with 50W light pipe excellent reproducibility and stability, and ultra-low detection limit, which has brought the modern technology to the extreme. 
    Features
    Fast simultaneous – the required measurement elements are quickly analyzed at the same time, generally giving results in tens of seconds.
    Low detection limit – using advanced MEDXRF technology, LSDCC core technology, to achieve ultra-low detection limits. Extremely reproducible and reproducible.
    Long-term stability – Variable gain digital multi-channel with PHA auto-tuning, drift correction, and offset correction for excellent long-term stability.
    Environmental protection and energy saving – radiation protection is up to the exemption requirement. No contact with the sample during the analysis, no pollution, no chemical reagents, no burning.
    Easy to use – touch screen operation. The sample is directly loaded into the sample cup. After putting the instrument into the instrument, just press the [Start] button to realize one-button operation.
    High reliability – integrated design, high degree of integration, strong environmental adaptability, strong anti-interference ability and high reliability.
    Cost-effective – no cylinder gas required, low operating and maintenance costs. The price is half of the foreign similar products. It is a truly cost-effective product. 
    Technical Parameters
    Measuring elements: Si, P, S, Cl (optional combination of any of B to Cl)
    X-ray tube: Voltage: ≤50keV, current: ≤2mA, power ≤50W, target: Ag (Mo, Rh, Pd, Cr, etc.)
    Detector: SDD, effective area: 20mm2, resolution: ≥123eV, count rate: ≤2Mcps, incident window: 8μm铍 (AP3.3 optional)
    Detection limit (300s): Si: 0.9ppm, P: 0.7ppm, S: 0.26ppm, Cl: 0.14ppm (standard type, 1 LSDDC crystal)
    Si: 0.7 ppm, P: 0.4 ppm, S: 0.15 ppm, Cl: 0.08 ppm (enhanced type, 3 LSDDC crystals)
    Measuring range: 3 times to 9.99% of the detection limit
    Linearity error, analysis accuracy: Measurement S: Meet the relevant requirements of GB/T 11140, ISO20884, SH/T 0842, ASTM D2622, D7039, D7220, etc.
    Si measurement: Meets the relevant requirements of ASTM D7757, SH/T 0706, SH/T 0058, etc.
    Measurement of Cl: Meets the relevant requirements of ASTM D7536, D49294, ISO 15597, and the like.
    P: Meets the relevant requirements of ASTM D6481, SH/T 0296, SH/T 0631, etc.
    System analysis time: 1 ~ 999s, recommended value: 300s for micro measurement, 60s for constant measurement
    Conditions of use: Ambient temperature: 5 ~ 40 ° C, relative humidity: ≤ 85% (30 ° C), power supply: 220V ± 20V, 50Hz, ≤ 200W
    Measuring atmosphere: self-inflating system or helium
    Size and weight: 330mm × 460mm × 350mm, 25kg
    Note: If the user believes that the standard DM2400 cannot meet the requirements, it can be submitted to the company, and the company can satisfy the user's requirements as much as possible. If a lower detection limit is required, the company can increase the crystal from one block to three to reduce the detection limit to 1/1.73. If you want to measure the elements of the atomic number below F, the company can select the SDD of the AP3.3 incident window for the user. If the user wants to measure trace amounts of Al and Si under the substrate of high S, the company can change the standard type of Ag target to Mo target to meet user requirements.

  • Introduction
    DM2400 monochromatic excitation energy dispersive X-ray fluorescence light element (Si, P, S, Cl) spectrometer, referred to as DM2400 MEDXRF light element spectrometer, is the company's research experience for decades of X-ray fluorescence spectrometer, in the company's original Based on DM series X-ray fluorescence analyzer, X-ray fluorescence multi-element analyzer, wavelength-dispersive X-ray fluorescence multi-channel spectrometer, etc., an XRF spectrometer that has reached the international advanced level has been developed. It uses the following technologies and devices to make the DM2400 with 50W light pipe excellent reproducibility and stability, and ultra-low detection limit, which has brought the modern technology to the extreme. 
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com