    Product Introduction
    The CEL-LPH120-254 Low-Pressure Mercury Lamp UV Light Source System is a high-intensity ultraviolet irradiation device equipped with a 120W low-pressure mercury amalgam lamp. It primarily emits ultraviolet radiation at wavelengths of 254nm and 185nm, making it suitable for various photochemical and ultraviolet irradiation applications.
    The system features a serpentine-shaped lamp tube manufactured from low-hydroxyl synthetic quartz, providing high radiation intensity and uniform illumination. With an irradiation area of approximately 128 × 128 mm, it supports both overhead projection irradiation and side irradiation configurations.
    Designed for stable, long-term operation, the CEL-LPH120-254 offers high radiation density, excellent temperature resistance, and flexible horizontal or vertical installation.

     


    Performance Features
    1. High-Intensity UV Output: Equipped with a 120W high-emission low-pressure mercury amalgam lamp, primarily delivering 254nm and 185nm ultraviolet wavelengths.
    2. Serpentine Lamp Design: The specially designed serpentine tube increases the effective irradiation area and helps achieve uniform UV intensity distribution.
    3. Solid Mercury Amalgam Technology: The mercury amalgam is bonded to the inner quartz surface, supporting high emission efficiency and extended service life.
    4. High-Temperature Resistance: Supports continuous stable operation at temperatures up to 105°C without affecting radiation intensity.
    5. Uniform Irradiation: An optimized airflow-supported bending structure prevents necking at the tube bends, reducing localized weak irradiation areas.
    6. Flexible Installation: Supports both horizontal and vertical installation for different experimental configurations.
    7.Dual Irradiation Modes: Enables both overhead projection and side irradiation.
    8. High-Quality Quartz Material: Uses low-hydroxyl synthetic quartz to support efficient ultraviolet transmission.

     


    Working Principle
    The CEL-LPH120-254 operates using low-pressure mercury amalgam discharge technology. When electrical power is applied to the mercury amalgam lamp after preheating, an electrical discharge excites mercury atoms, generating ultraviolet radiation primarily at wavelengths of 254nm and 185nm.
    The ultraviolet radiation passes through the synthetic quartz lamp tube and is directed toward the target material. Its serpentine configuration provides a relatively large irradiation surface and helps distribute UV energy evenly across the treatment area.
    Depending on the experimental setup, the system can deliver ultraviolet radiation through overhead projection or side irradiation, making it suitable for photochemical reactions, UV-assisted material treatment, and laboratory irradiation processes.

     


    Technical Parameters
    Parameter Specification
    Model CEL-LPH120-254
    Product Type Low-Pressure Mercury Lamp UV Light Source System
    Rated Power 120W
    Main UV Wavelengths 254nm and 185nm
    Lamp Type High-emission low-pressure mercury amalgam lamp
    Lamp Structure Serpentine-shaped
    Irradiation Area 128 × 128 mm
    Lamp Material Low-hydroxyl synthetic quartz
    Lamp Current 1200mA
    Lamp Dimensions Approximately 140 × 140 mm (overall external dimensions)
    Lamp Connection Double-ended pins
    Installation Orientation Horizontal or vertical
    Maximum Operating Temperature 105°C
    Starting Method Preheating start
    Irradiation Modes Overhead projection and side irradiation
    Standard Configuration
    Item Description Quantity
    1 LPH120 Main Unit (including one 254nm lamp tube) 1
    2 Projection Support Rods 4
    3 Power Cord, User Manual, Certificate of Conformity, Acceptance Form, and Warranty Certificate 1 Set
    Optional Accessory:
    •   CEL-LB70 Protective Enclosure: Recommended for safer operation due to the high-intensity ultraviolet radiation produced by the system.

     


    Application Scenarios
    • Photochemical Research: Provides ultraviolet irradiation for laboratory photochemical experiments and reaction studies.
    •  Material Surface Treatment: Supports UV-assisted modification and treatment of material surfaces.
    •  UV Oxidation Research: Provides UV radiation for laboratory studies involving ultraviolet oxidation processes.
    •  Environmental Research: Suitable for experimental research on UV-assisted pollutant degradation and related treatment technologies.
    • Chemical Laboratory Applications: Used as a UV irradiation source in chemical synthesis and photochemical reaction experiments.
    •  Material Science Research: Supports investigations into ultraviolet effects on material properties and surface characteristics.

     


    Comparison: CEL-LPH120-254 vs. Conventional UV Lamp Systems
    Feature CEL-LPH120-254 Conventional UV Lamp Systems
    Lamp Technology Low-pressure mercury amalgam Depends on lamp type
    Rated Power 120W Model-dependent
    UV Wavelengths 254nm and 185nm Often wavelength-specific
    Lamp Structure Serpentine-shaped Straight or conventional tube
    Irradiation Area 128 × 128 mm Depends on configuration
    Irradiation Uniformity Optimized serpentine design Depends on lamp arrangement
    Temperature Resistance Up to 105°C Model-dependent
    Installation Horizontal or vertical Depends on design
    Irradiation Modes Projection and side irradiation Depends on configuration
     


    Frequently Asked Questions (FAQ)
    Q1: What is the CEL-LPH120-254 UV Light Source System used for?
    It is designed for high-intensity ultraviolet irradiation in photochemical research, material treatment, UV oxidation experiments, and laboratory applications.
    Q2: What ultraviolet wavelengths does the system produce?
    The system primarily produces ultraviolet radiation at 254nm and 185nm using a low-pressure mercury amalgam lamp.
    Q3: What is the rated power of the UV lamp?
    The lamp has a rated power of 120W and an operating current of 1200mA.
    Q4: What is the irradiation area of the CEL-LPH120-254?
    Its specified irradiation area is approximately 128 × 128 mm.
    Q5: Can the UV lamp operate at high temperatures?
    Yes. The lamp is designed to operate continuously and stably at temperatures up to 105°C without affecting its radiation intensity.
    Q6: Does the system support different installation orientations?
    Yes. The mercury amalgam is bonded to the inner quartz surface, allowing the lamp to be installed horizontally or vertically.
    Q7: What irradiation modes are supported?
    The system supports both overhead projection irradiation and side irradiation.
    Q8: Is a protective enclosure available?
    Yes. The optional CEL-LB70 protective enclosure is recommended to reduce exposure risks associated with high-intensity ultraviolet radiation.
    Q9: What accessories are included with the system?
    The standard package includes one LPH120 main unit with a 254nm lamp, four projection support rods, a power cord, user documentation, and warranty-related certificates.


  • Frequently Asked Questions (FAQ)
    Q1: What is the CEL-LPH120-254 UV Light Source System used for?
    It is designed for high-intensity ultraviolet irradiation in photochemical research, material treatment, UV oxidation experiments, and laboratory applications.
    Q2: What ultraviolet wavelengths does the system produce?
    The system primarily produces ultraviolet radiation at 254nm and 185nm using a low-pressure mercury amalgam lamp.
    Q3: What is the rated power of the UV lamp?
    The lamp has a rated power of 120W and an operating current of 1200mA.
    Q4: What is the irradiation area of the CEL-LPH120-254?
    Its specified irradiation area is approximately 128 × 128 mm.
    Q5: Can the UV lamp operate at high temperatures?
    Yes. The lamp is designed to operate continuously and stably at temperatures up to 105°C without affecting its radiation intensity.
    Q6: Does the system support different installation orientations?
    Yes. The mercury amalgam is bonded to the inner quartz surface, allowing the lamp to be installed horizontally or vertically.
    Q7: What irradiation modes are supported?
    The system supports both overhead projection irradiation and side irradiation.
    Q8: Is a protective enclosure available?
    Yes. The optional CEL-LB70 protective enclosure is recommended to reduce exposure risks associated with high-intensity ultraviolet radiation.
    Q9: What accessories are included with the system?
    The standard package includes one LPH120 main unit with a 254nm lamp, four projection support rods, a power cord, user documentation, and warranty-related certificates.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.