BLJ-B 180 Degree Peel Strength Tester

Product ID:HZBZmcbl012

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberBLJ-B
    Brand NameSANQUAN
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    BLJ-B 180 Degree Peel Strength Tester
     
    Product Introduction
    The BLJ-B 180 Degree Peel Strength Tester is a high-precision automatic testing instrument designed for 180° peel strength testing of adhesive tapes, labels, medical patches, protective films, release papers, composite films, and other adhesive-related products.
    The tester adopts microcomputer control, precision force sensing, automatic testing, and large LCD display. After the test specimen is correctly prepared and clamped, the instrument automatically performs the peel test and records the test force. Test results can be output through the built-in micro-printer.
    Its horizontal test structure helps prevent the fixture weight from influencing sensor measurements, supporting stable and accurate peel force testing. The BLJ-B is suitable for quality inspection organizations, drug testing agencies, adhesive tape and label manufacturers, packaging-related industries, and research laboratories.

     


    Performance Features
    • Automatic microcomputer control for convenient operation and consistent testing.
    •   Large LCD display with a durable PVC operation panel.
    •  Horizontal testing structure helps prevent fixture weight from affecting sensor values.
    •   Precision force sensor supports accurate peel force measurement.
    •   Built-in micro-printer provides fast test-data output.
    •  Stepless speed adjustment from 1 to 500mm/min for different testing standards.
    •  Test force hold function makes maximum or measured force values easier to observe.
    •   Minimum force reading of 0.01N for detailed peel-force measurement.
    •   Minimum displacement reading of 0.01mm.
    •   Metal control buttons provide durable operation.
    •   Suitable for a wide range of adhesive and flexible-film peel strength tests.

     


    Test Principle
    The test specimen is prepared according to the applicable laboratory test method. A 2000g ±50g standard pressure roller is used to roll the specimen three times under the specified conditions.
    After conditioning, the specimen is placed and clamped on the peel tester. The bonded material is then peeled from the standard plate at a 180° angle at a preset speed.
    During peeling, the precision force sensor continuously detects the force required to separate the specimen. The BLJ-B records the peel force and displays the measured result, while the built-in printer can provide a printed test record.

     


    Technical Specifications
    Parameter Specification
    Model BLJ-B
    Test Type 180° Peel Strength Test
    Standard Pressure Roller 2000g ± 50g
    Maximum Test Force 200N
    Effective Test Force Range 2%–100% FS
    Minimum Force Reading 0.01N
    Minimum Displacement Reading 0.01mm
    Test Accuracy Grade 1
    Test Speed 1–500mm/min, stepless
    Speed Accuracy ≤ ±2%
    Sample Width 0 < L ≤ 30mm
    Display Large LCD
    Control Microcomputer
    Data Output Built-in micro-printer
    Test Force Function Force value hold
    Dimensions 550 × 370 × 240mm (L × W × H)
    Net Weight 28kg
    Ambient Temperature 15–50°C
    Relative Humidity ≤80%, non-condensing
    Power Supply 220V, 50Hz
     


    Application Scenarios
    The BLJ-B 180 Degree Peel Strength Tester is suitable for peel-strength evaluation of:
    •   Adhesive tapes
    •   Self-adhesive labels
    •   Medical patches
    •   Protective films
    •   Release papers
    •   Composite films
    •   Adhesive-coated materials
    •   Flexible packaging and related materials
    Typical users include:
    •   Quality inspection agencies
    •   Drug testing agencies
    •   Adhesive tape manufacturers
    •   Label manufacturers
    •   Packaging material manufacturers
    •   Research and testing laboratories
    •   R&D and quality-control departments

     


    Comparison: BLJ-B vs. Conventional Peel Testing
    Feature BLJ-B 180 Degree Peel Strength Tester Conventional Manual Peel Test
    Test Mode Automatic Manual
    Peel Angle 180° Operator-dependent
    Test Speed 1–500mm/min, stepless Often manually controlled
    Maximum Test Force 200N Depends on method/device
    Force Resolution 0.01N Depends on instrument
    Displacement Resolution 0.01mm Often limited
    Force Hold Yes Usually unavailable
    Data Printing Built-in micro-printer Usually manual recording
    Control Microcomputer Manual
    Sensor Structure Precision force sensor Depends on equipment
    Suitable Materials Tape, labels, patches, films, release papers, composite films Depends on test method
     


    FAQ
    1.  What does the BLJ-B test?
    The BLJ-B is designed for 180° peel strength testing of adhesive tapes, labels, medical patches, protective films, release papers, composite films, and similar products.
    2. What is the maximum test force?
    The maximum test force is 200N, with an effective force range of 2%–100% FS.
    3. What is the minimum force reading?
    The minimum test-force reading is 0.01N.
    4. What is the test speed range?
    The BLJ-B provides stepless speed adjustment from 1 to 500mm/min, with speed accuracy of ≤±2%.
    5. What is the standard pressure roller weight?
    The standard pressure roller is 2000g ±50g.
    6. What sample width can be tested?
    The specified sample width is 0 < L ≤30mm.
    7. Does the instrument automatically record the test result?
    Yes. The microcomputer-controlled tester records the test force, and the built-in micro-printer can output test data.
    8. Does the BLJ-B have a force-hold function?
    Yes. The instrument provides a test force value hold function, making the measured result easier to observe.
    9. What are the required environmental conditions?
    The recommended operating environment is 15–50°C with relative humidity of ≤80%, non-condensing.
    10. What is the power supply?
    The standard power supply is 220V, 50Hz.


  • FAQ
    1.  What does the BLJ-B test?
    The BLJ-B is designed for 180° peel strength testing of adhesive tapes, labels, medical patches, protective films, release papers, composite films, and similar products.
    2. What is the maximum test force?
    The maximum test force is 200N, with an effective force range of 2%–100% FS.
    3. What is the minimum force reading?
    The minimum test-force reading is 0.01N.
    4. What is the test speed range?
    The BLJ-B provides stepless speed adjustment from 1 to 500mm/min, with speed accuracy of ≤±2%.
    5. What is the standard pressure roller weight?
    The standard pressure roller is 2000g ±50g.
    6. What sample width can be tested?
    The specified sample width is 0 < L ≤30mm.
    7. Does the instrument automatically record the test result?
    Yes. The microcomputer-controlled tester records the test force, and the built-in micro-printer can output test data.
    8. Does the BLJ-B have a force-hold function?
    Yes. The instrument provides a test force value hold function, making the measured result easier to observe.
    9. What are the required environmental conditions?
    The recommended operating environment is 15–50°C with relative humidity of ≤80%, non-condensing.
    10. What is the power supply?
    The standard power supply is 220V, 50Hz.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com