Position: Home > > Environmental monitoring and analysis > Air sampling equipment > Smoke / flugas sampler > ZR-D09QT Multi-Parameter Direct Reading Dust Sampling Tube

ZR-D09QT Multi-Parameter Direct Reading Dust Sampling Tube

Product ID:HQCYyq038

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberZR-D09QT
    Brand NameQDZHONGRUI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    ZR-D09QT Multi-Parameter Direct Reading Dust Sampling Tube
    Product Introduction
    The ZR-D09QT Multi-Parameter Direct Reading Dust Sampling Tube is a professional particulate monitoring device designed for measuring dust concentration in organized emissions from fixed pollution sources.
    Based on the beta ray absorption measurement principle combined with filter tape sampling technology, the ZR-D09QT works together with a dust monitoring host to achieve automatic sampling and accurate real-time particulate concentration measurement.
    With a compact structure, high measurement accuracy, and convenient installation, the direct reading dust sampling tube can also measure multiple flue gas parameters including dynamic pressure, static pressure, temperature, velocity, and standard flow rate through an independent gas sampling pipeline.
    The instrument is widely used in environmental protection monitoring, emission inspection, industrial factories, power plants, steel plants, cement plants, boilers, chemical industries, research institutions, occupational safety monitoring, and educational applications.

     

    Key Features & Benefits
    1. Beta Ray Direct Reading Dust Measurement Technology
    •  Uses beta ray absorption combined with filter tape sampling.
    •  Provides direct on-site particulate concentration readings.
    •  Supports short-term online monitoring.
    •  Suitable for environmental enforcement and rapid inspection.
    2. Multi-Parameter Flue Gas Measurement
    The sampling tube can measure:
    •  Dust concentration.
    •  Moisture content.
    •  Dynamic pressure.
    •  Static pressure.
    •  Gas temperature.
    •  Gas velocity.
    •  Standard flow rate.
    3. Real-Time Humidity Measurement
    •  Built-in moisture measurement function.
    •  Improves accuracy under changing flue gas conditions.
    •  Suitable for high humidity emission environments.
    4. Integrated Dust and Gas Sampling Capability
    •  Supports flue gas pretreatment.
    •  Can work with electrochemical sensors or UV cold-dry gas analysis systems.
    •  Enables simultaneous dust and gas measurement.
    •  Supports oxygen concentration measurement during dust sampling.
    5. Intelligent Operation and Safety Design
    •  Color touchscreen operation.
    •  Real-time display of instrument status and parameters.
    •  Tilt angle monitoring with alarm function.
    •  Fault alarm system.
    6. Reliable Sampling Structure
    •  Stable front and rear paper feeding mechanism.
    •  Inert surface-treated sampling tube wall reduces particle adsorption.
    •  Removable Pitot tube for easy maintenance.
    •  Optional filter cartridge sampling nozzle for high concentration conditions.

     

    Working Principle
    The ZR-D09QT Direct Reading Dust Sampling Tube operates based on the beta ray absorption method.
    During sampling, particulate matter from the flue gas is collected onto a filter tape. A beta radiation source emits beta particles through the collected dust layer. The amount of beta ray attenuation changes according to the mass of deposited particles.
    By measuring the difference in beta ray absorption before and after particle collection, the system calculates the mass concentration of particulate matter in the sampled gas.
    The instrument integrates flow, temperature, pressure, and humidity measurements to compensate for environmental factors, providing accurate real-time dust concentration results.

     

    Technical Specifications
    Parameter Specification
    Model ZR-D09QT
    Instrument Type Multi-Parameter Direct Reading Dust Sampling Tube
    Measurement Principle Beta Ray Absorption + Filter Tape Sampling
    Application Fixed pollution source particulate emission monitoring
    Sampling Flow Rate 0-50 L/min
    Calibration Method Standard membrane calibration
    Power Supply DC24V 10A
    Power Consumption <240W
    Sampling Tube Length Standard 1.5m (customizable)
    Dimensions 340 × 135 × 270 mm
    Display Color touchscreen
    Communication Bluetooth communication with dust host (optional)
    Sampling Method Automatic sampling
    Moisture Measurement Real-time measurement supported
    Gas Parameter Measurement Pressure, temperature, velocity, flow rate
     

    Application Scenarios
    Environmental Monitoring
    •  Fixed pollution source inspection.
    •  Industrial emission compliance testing.
    •  Environmental law enforcement.
    Power Plants
    •  Boiler dust emission monitoring.
    •  Flue gas particulate testing.
    •  Pollution control evaluation.
    Industrial Manufacturing
    Suitable for:
    •  Steel plants.
    •  Cement plants.
    •  Paper mills.
    •  Chemical factories.
    •  Metallurgical industries.
    •  Ceramic factories.
    Mining & Material Industries
    •  Aluminum industry.
    •  Magnesium industry.
    •  Zinc industry.
    •  Titanium industry.
    •  Silicon industry.
    Research and Safety Monitoring
    •  Scientific research institutions.
    •  Universities and laboratories.
    •  Occupational health and safety inspection.

     

    ZR-D09QT Direct Reading Dust Sampling Tube vs Traditional Dust Samplers
    Feature ZR-D09QT Direct Reading Sampling Tube Traditional Dust Sampling Equipment
    Measurement Method Beta ray direct reading Manual weighing method
    Real-Time Measurement Available Usually unavailable
    Sampling Automation Automatic sampling More manual operation
    Multi-Parameter Detection Supports dust, gas, temperature, pressure, flow Usually single parameter
    Humidity Measurement Real-time moisture measurement Often requires separate measurement
    Portability Compact and lightweight Larger equipment
    Field Application Suitable for rapid inspection More suitable for laboratory analysis
    Data Monitoring Real-time display and communication Limited data functions
     

    Frequently Asked Questions (FAQ)
    Q1: What is the ZR-D09QT Dust Sampling Tube used for?
    The ZR-D09QT is used for measuring particulate concentration in organized emissions from fixed pollution sources such as industrial boilers, power plants, and factories.
    Q2: What measurement principle does the instrument use?
    It uses the beta ray absorption method combined with filter tape sampling technology to directly measure dust concentration.
    Q3: Can the ZR-D09QT measure other flue gas parameters?
    Yes. When combined with an independent sampling pipeline, it can measure dynamic pressure, static pressure, temperature, velocity, and standard flow rate.
    Q4: Does the instrument support real-time humidity measurement?
    Yes. The ZR-D09QT includes real-time moisture content measurement to improve measurement accuracy.
    Q5: Can it perform simultaneous dust and gas measurement?
    Yes. With optional gas analysis modules, it can perform simultaneous dust sampling and gas component measurement, including oxygen concentration detection.
    Q6: What is the maximum sampling flow rate?
    The sampling flow rate range is 0-50 L/min.
    Q7: Can the sampling tube be customized?
    Yes. The standard sampling tube length is 1.5m, and customized lengths are available according to application requirements.
    Q8: Is the instrument suitable for high dust concentration environments?
    Yes. For concentrations above 50mg/m³, an optional filter cartridge sampling nozzle can be used.

     

    Product Summary
    The ZR-D09QT Multi-Parameter Direct Reading Dust Sampling Tube is an advanced beta ray dust monitoring instrument designed for accurate particulate emission measurement in fixed pollution sources. With direct reading capability, multi-parameter detection, real-time humidity measurement, intelligent operation, and portable design, it provides an efficient solution for environmental monitoring, industrial emission testing, pollution control, and workplace safety applications.
     
     


     
     
  • Frequently Asked Questions (FAQ)
    Q1: What is the ZR-D09QT Dust Sampling Tube used for?
    The ZR-D09QT is used for measuring particulate concentration in organized emissions from fixed pollution sources such as industrial boilers, power plants, and factories.
    Q2: What measurement principle does the instrument use?
    It uses the beta ray absorption method combined with filter tape sampling technology to directly measure dust concentration.
    Q3: Can the ZR-D09QT measure other flue gas parameters?
    Yes. When combined with an independent sampling pipeline, it can measure dynamic pressure, static pressure, temperature, velocity, and standard flow rate.
    Q4: Does the instrument support real-time humidity measurement?
    Yes. The ZR-D09QT includes real-time moisture content measurement to improve measurement accuracy.
    Q5: Can it perform simultaneous dust and gas measurement?
    Yes. With optional gas analysis modules, it can perform simultaneous dust sampling and gas component measurement, including oxygen concentration detection.
    Q6: What is the maximum sampling flow rate?
    The sampling flow rate range is 0-50 L/min.
    Q7: Can the sampling tube be customized?
    Yes. The standard sampling tube length is 1.5m, and customized lengths are available according to application requirements.
    Q8: Is the instrument suitable for high dust concentration environments?
    Yes. For concentrations above 50mg/m³, an optional filter cartridge sampling nozzle can be used.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com