Position: Home > > Environmental monitoring and analysis > Air sampling equipment > Particulate sampler > ZR-3923 Ambient Air Particulate Matter Comprehensive Sampler

ZR-3923 Ambient Air Particulate Matter Comprehensive Sampler

Product ID:HQCYklw031

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberZR-3923
    Brand NameQDZHONGRUI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    ZR-3923 Ambient Air Particulate Matter Comprehensive Sampler
     
    Product Introduction
    The ZR-3923 Ambient Air Particulate Matter Comprehensive Sampler is a multifunctional environmental monitoring instrument designed to collect airborne particulate matter and gaseous pollutants from ambient and indoor air. Using the filter membrane method, it captures total suspended particulates (TSP), PM10, and PM2.5. It also supports gaseous pollutant collection through solution absorption, adsorption tubes, and other solid-phase adsorption methods.
    Available in two configurations, the ZR-3923 offers an A model with temperature maintenance and a B model with heating functionality. Its five-channel simultaneous sampling capability allows particulate matter and gaseous pollutants to be collected concurrently. Featuring a high-efficiency rechargeable lithium battery, a high-performance brushless sampling pump, and intelligent touchscreen operation, it is suitable for environmental monitoring, occupational health, industrial safety, scientific research, and educational applications.

     


    Performance Features
    1. Intuitive Touchscreen Operation: Equipped with a 4.3-inch high-resolution color LCD touchscreen with additional physical buttons for convenient operation.
    2. Built-In Rechargeable Battery: Features a high-efficiency lithium battery for sampling in locations without an external power supply.
    3. Optional Remote Data Transmission: Supports an optional GPRS module for remote data communication.
    4. Portable Design: Compact dimensions and lightweight construction make transportation and field deployment convenient.
    5. All-Weather Protection: Rainproof, dustproof, antistatic, and impact-resistant design supports operation in rain, snow, dusty environments, and heavy haze.
    6. Five-Channel Simultaneous Sampling: Collects particulate matter and gaseous pollutants through five sampling channels simultaneously.
    7. Dual Temperature-Control Options: The A model features a temperature-maintaining insulated box for wide-temperature sampling, while the B model provides heating for reliable operation in low-temperature environments.
    8.High-Performance Sampling Pump: Uses a high-flow, high-negative-pressure brushless pump. At 100L/min, the load capacity exceeds 6kPa, with continuous operation exceeding 5,000 hours at 80% rated load.
    9. Pump Protection: Integrated controller provides gas-path blockage prevention and low-flow protection.
    10. Multiple Sampling Modes: Supports constant-flow, timed, intermittent, and
    24-hour continuous sampling, with independently adjustable flow rates and sampling durations.
    11. High-Precision Flow Measurement: Uses a corrosion-resistant electronic flowmeter designed to withstand high humidity and maintain accurate sampling parameters.
    12. Large-Capacity Data Storage: Built-in memory supports instantaneous data recording and USB data export.
    13. Wireless Printing: Supports Bluetooth wireless printing for convenient field reporting.
    14. Antistatic Particle Cutters: Aluminum-alloy TSP, PM10, and PM2.5 cutters help reduce electrostatic particle adsorption.
    15. Environmental Parameter Measurement: Atmospheric pressure and ambient temperature can be measured or manually entered. The imported pressure sensor is maintenance-free and requires no routine calibration.
    16. Power Interruption Protection: Automatically saves sampling data during power failures and resumes sampling after power is restored.

     


    Working Principle
    The ZR-3923 Ambient Air Particulate Matter Comprehensive Sampler uses multiple sampling methods to collect airborne particulate matter and gaseous pollutants.
    For particulate matter measurement, ambient air passes through dedicated TSP, PM10, or PM2.5 size-selective cutters before particles are collected on filter membranes. The collected particles can subsequently be analyzed to determine particulate matter concentrations.
    For gaseous pollutant sampling, the instrument supports solution absorption, adsorption tube collection, and other solid-phase adsorption methods. Its five-channel configuration enables simultaneous collection of different pollutants.
    A high-performance brushless pump maintains the required sampling flow, while the electronic flowmeter monitors sampling parameters. The intelligent control system manages sampling modes, temperature conditions, data recording, and operational protection to support reliable long-term environmental monitoring.

     


    Technical Parameters
    Parameter Specification
    Model ZR-3923
    Product Type Ambient Air Particulate Matter Comprehensive Sampler
    Available Versions A: Temperature Maintenance; B: Heating
    Particulate Matter Sampling TSP, PM10, PM2.5
    Gas Sampling Methods Solution absorption, adsorption tubes, solid-phase adsorption
    Sampling Channels 5 channels simultaneously
    Sampling Flow Rate 15–130L/min
    Sampling Pump High-flow, high-negative-pressure brushless pump
    Load Capacity >6kPa at 100L/min
    Continuous Operating Life >5,000 hours at 80% rated load
    Display 4.3-inch color LCD touchscreen
    Sampling Modes Constant-flow, timed, intermittent, 24-hour continuous
    Temperature Control A: Temperature maintenance; B: Heating
    Data Storage Built-in large-capacity memory
    Data Export USB
    Remote Communication Optional GPRS
    Printing Bluetooth wireless printing
    Pressure Measurement Imported pressure sensor
    Working Power Supply AC 220V ±10%, 50Hz
    Main Unit Dimensions 380 × 148 × 220mm (L × W × H)
    Main Unit Weight Approx. 4.5kg (including battery)
    Power Consumption ≤120W
     


    Application Scenarios
    The ZR-3923 is suitable for comprehensive particulate matter and gaseous pollutant monitoring across various environmental and occupational settings.
    • Ambient Air Quality Monitoring: Collection of TSP, PM10, PM2.5, and gaseous pollutants for outdoor air quality assessment.
    •  Indoor Air Quality Monitoring: Sampling of airborne particles and harmful gases in indoor environments.
    • Environmental Protection Monitoring: Supports environmental pollution investigation, routine monitoring, and regulatory testing.
    •  Occupational Health: Air sampling for workplace exposure assessment and occupational hygiene research.
    • Industrial Safety: Monitoring particulate matter and gaseous pollutants in industrial working environments.
    •  Scientific Research: Supports atmospheric pollution studies, aerosol research, and environmental science experiments.
    • Educational Institutions: Suitable for air pollution research, teaching laboratories, and environmental monitoring projects.
    • Military Applications: Supports specialized ambient air sampling and environmental monitoring requirements.

     


    ZR-3923 A vs. ZR-3923 B
    Comparison ZR-3923 A ZR-3923 B
    Insulated Box Function Temperature maintenance Heating
    Main Purpose Maintains a stable sampling temperature Provides heating in low-temperature conditions
    Sampling Environment Wide-temperature conditions Cold environments
    Particulate Sampling TSP, PM10, PM2.5 TSP, PM10, PM2.5
    Gas Sampling Supported Supported
    Five-Channel Sampling Supported Supported
    ZR-3923 vs. Conventional Air Samplers
    Comparison ZR-3923 Conventional Air Samplers
    Sampling Targets TSP, PM10, PM2.5, gaseous pollutants Often limited sampling targets
    Sampling Channels Five simultaneous channels Model-dependent
    Sampling Flow Rate 15–130L/min Model-dependent
    Sampling Modes Multiple automatic modes Model-dependent
    Power Supply AC and built-in rechargeable battery Model-dependent
    Temperature Options Temperature maintenance or heating Model-dependent
    Data Storage Built-in memory and USB export Model-dependent
    Remote Communication Optional GPRS Model-dependent
    Field Printing Bluetooth wireless printing Model-dependent
    Environmental Protection Rainproof, dustproof, antistatic, impact-resistant Model-dependent
     


    Frequently Asked Questions (FAQ)
    1. What is the ZR-3923 Ambient Air Particulate Matter Comprehensive Sampler used for?
    It is designed to collect TSP, PM10, PM2.5, and various gaseous pollutants from ambient and indoor air for environmental and occupational monitoring.
    2. What is the difference between the ZR-3923 A and B models?
    The A model features a temperature-maintaining insulated box, while the B model uses a heating function to ensure reliable sampling under low-temperature conditions.
    3. Can the ZR-3923 collect particulate matter and gaseous pollutants simultaneously?
    Yes. Its five-channel sampling system supports simultaneous collection of airborne particulate matter and gaseous pollutants.
    4. What is the sampling flow rate?
    The adjustable sampling flow rate ranges from 15 to 130L/min.
    5. Can the instrument operate without an external power supply?
    Yes. It features a built-in rechargeable lithium battery that supports sampling in locations without an external power supply.
    6. What sampling modes does the ZR-3923 support?
    It supports constant-flow sampling, timed sampling, intermittent sampling, and 24-hour continuous sampling. Flow rate and sampling duration can be controlled independently.
    7. Can sampling data be exported to a computer?
    Yes. The instrument features built-in data storage and supports USB flash drive export. An optional GPRS module is also available for remote data transmission.
    8. Is the ZR-3923 suitable for outdoor operation?
    Yes. Its rainproof, dustproof, antistatic, and impact-resistant design supports field operation in challenging weather and environmental conditions.
    9. Does the ZR-3923 support automatic recovery after a power failure?
    Yes. Sampling data and operating status are automatically protected during power interruptions, allowing sampling to resume after power is restored.


  • Frequently Asked Questions (FAQ)
    1. What is the ZR-3923 Ambient Air Particulate Matter Comprehensive Sampler used for?
    It is designed to collect TSP, PM10, PM2.5, and various gaseous pollutants from ambient and indoor air for environmental and occupational monitoring.
    2. What is the difference between the ZR-3923 A and B models?
    The A model features a temperature-maintaining insulated box, while the B model uses a heating function to ensure reliable sampling under low-temperature conditions.
    3. Can the ZR-3923 collect particulate matter and gaseous pollutants simultaneously?
    Yes. Its five-channel sampling system supports simultaneous collection of airborne particulate matter and gaseous pollutants.
    4. What is the sampling flow rate?
    The adjustable sampling flow rate ranges from 15 to 130L/min.
    5. Can the instrument operate without an external power supply?
    Yes. It features a built-in rechargeable lithium battery that supports sampling in locations without an external power supply.
    6. What sampling modes does the ZR-3923 support?
    It supports constant-flow sampling, timed sampling, intermittent sampling, and 24-hour continuous sampling. Flow rate and sampling duration can be controlled independently.
    7. Can sampling data be exported to a computer?
    Yes. The instrument features built-in data storage and supports USB flash drive export. An optional GPRS module is also available for remote data transmission.
    8. Is the ZR-3923 suitable for outdoor operation?
    Yes. Its rainproof, dustproof, antistatic, and impact-resistant design supports field operation in challenging weather and environmental conditions.
    9. Does the ZR-3923 support automatic recovery after a power failure?
    Yes. Sampling data and operating status are automatically protected during power interruptions, allowing sampling to resume after power is restored.


     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com