Position: Home > > Environmental monitoring and analysis > Air sampling equipment > Particulate sampler > ZR-3920G High-Vacuum Ambient Air Particulate Matter Sampler

ZR-3920G High-Vacuum Ambient Air Particulate Matter Sampler

Product ID:HQCYklw029

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberZR-3920G
    Brand NameQDZHONGRUI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    ZR-3920G High-Vacuum Ambient Air Particulate Matter Sampler
     
    Product Introduction
    The ZR-3920G High-Vacuum Ambient Air Particulate Matter Sampler is designed for specialized ambient air sampling of fluoride, heavy metals, and semi-volatile organic compounds (SVOCs). It can also collect total suspended particles (TSP), PM10, and PM2.5.
    Equipped with an imported high-flow, high-vacuum brushless sampling pump, the ZR-3920G provides a load capacity exceeding 20 kPa at 50 L/min. Interchangeable sampling heads allow the instrument to accommodate different sampling requirements and filter media.
    With automatic atmospheric pressure and temperature measurement, standard-volume calculation, multiple sampling modes, and built-in data storage, the ZR-3920G is suitable for routine aerosol monitoring and environmental air quality investigations.

     


    Performance Features
    •   Multi-Target Sampling: Supports sampling of fluoride, heavy metals, SVOCs, TSP, PM10, and PM2.5.
    • High-Vacuum Sampling Pump: Uses an imported, high-flow, long-life brushless pump with a load capacity exceeding 20 kPa at 50 L/min.
    • Long Continuous Operation: Supports continuous operation exceeding 20,000 hours at 80% rated load.
    •   Interchangeable Sampling Heads: Different sampling heads can be selected for TSP, PM10, PM2.5, fluoride, airborne heavy metals, and SVOCs. The fluoride sampling head is included as standard.
    • Multiple Filter Media Compatibility: Accommodates glass fiber filters, cellulose nitrate membranes, perchloroethylene membranes, PTFE membranes, and quartz fiber filters. It also supports VOC sampling containers equipped with PUF adsorbent resin.
    • Outdoor Protection: Water-resistant, dust-resistant, and impact-resistant construction supports operation in rain, snow, dusty environments, and heavy haze.
    • Touchscreen Operation: A 5-inch color touchscreen provides clear data display and convenient operation.
    • Pump Protection: Built-in airflow blockage and low-flow protection help safeguard the sampling system.
    •  Accurate Flow Measurement: High-precision electronic flow meters provide corrosion resistance and humidity tolerance for stable flow control and accurate sampling volume measurement.
    •  Environmental Parameter Monitoring: Automatically measures atmospheric pressure and temperature and calculates standard-condition sampling volume.
    •  Imported Pressure Sensor: Uses an imported pressure sensor for reliable pressure measurement.
    •  Flexible Sampling Modes: Supports timed sampling, intermittent sampling, and 24-hour continuous sampling.
    • Data Storage and Export: Built-in large-capacity memory records instantaneous data and supports USB export in TXT and CSV formats.
    •   Power Failure Protection: Automatically protects sampling data during power interruptions and resumes sampling when power is restored.
    • Optional Printing: An optional printing module is available for sampling records.

     


    Working Principle
    The ZR-3920G draws ambient air through a selected sampling head using its high-vacuum brushless sampling pump. Depending on the sampling target, the appropriate inlet and collection medium capture airborne particles or associated pollutants.
    Different sampling heads and filter media are used for TSP, PM10, PM2.5, fluoride, heavy metals, and SVOCs. For SVOC sampling, the instrument can accommodate sampling containers equipped with PUF adsorbent resin.
    During operation, the instrument monitors sampling flow, atmospheric pressure, and temperature. It automatically calculates the sampling volume under standard conditions and records the relevant data for subsequent laboratory analysis.

     


    Technical Parameters
    Parameter Specification
    Flow Stability ≤ ±5% within 1 hour
    Flow Range 80–120 L/min
    Operating Duration Under High Flow and Resistance 2–8 hours
    Pump Load Capacity >20 kPa at 100 L/min (as specified in the technical parameters)
    Pump Performance >20 kPa load capacity at 50 L/min (as described in the product introduction)
    Service Life at Maximum Flow and Resistance ≥5,000 hours
    Maximum Flow Error Better than ±2.5%
    Sampling Targets Fluoride, heavy metals, SVOCs, TSP, PM10, PM2.5
    Sampling Modes Timed, intermittent, and 24-hour continuous sampling
    Display 5-inch color touchscreen
    Data Export USB; TXT and CSV formats
    Sampling Head Fluoride sampling head included as standard; other heads optional
    Printing Optional printing module
    Note: The source specifies pump load capacity as greater than 20 kPa at both 50 L/min in the product introduction and 100 L/min in the technical parameters. These operating conditions should be confirmed with the manufacturer.
     


    Application Scenarios
    The ZR-3920G is suitable for environmental monitoring, laboratory sampling, and specialized air pollution investigations.
    •  Fluoride Monitoring: Collection of airborne fluoride using the standard fluoride sampling head.
    •  Heavy Metal Analysis: Sampling airborne particulate matter containing lead and other metal elements.
    • SVOC Monitoring: Collection of semi-volatile organic compounds using compatible sampling configurations.
    • Particulate Matter Monitoring: Collection of TSP, PM10, and PM2.5 for gravimetric analysis.
    • Environmental Protection: Routine ambient air pollution monitoring and environmental investigations.
    • Occupational Health and Safety: Air sampling for workplace exposure assessment.
    •   Scientific Research: Aerosol, atmospheric chemistry, and air pollution studies.
    • Public Health and Military Applications: Ambient air sampling for environmental safety and research purposes.

     


    Applicable Standards
    The ZR-3920G is designed for sampling applications associated with the following standards and technical specifications:
    Standard Description
    HJ 955-2018 Determination of Fluoride in Ambient Air – Filter Sampling / Fluoride Ion-Selective Electrode Method
    HJ 691-2014 Technical Guidelines for Sampling Semi-Volatile Organic Compounds in Ambient Air
    HJ 657-2013 Determination of Lead and Other Metal Elements in Ambient Air and Waste Gas Particulate Matter by ICP-MS
    HJ 618-2011 Determination of PM10 and PM2.5 in Ambient Air – Gravimetric Method
    HJ 656-2013 Technical Specifications for Manual Monitoring of Ambient Air PM2.5 – Gravimetric Method
    HJ 646-2013 Determination of Polycyclic Aromatic Hydrocarbons in Ambient Air and Waste Gas – Gas Chromatography-Mass Spectrometry
    HJ/T 374-2007 Technical Requirements and Test Methods for Total Suspended Particulate Samplers
    HJ 93-2013 Technical Requirements and Test Methods for Ambient Air PM10 and PM2.5 Samplers
    JJG 943-2011 Total Suspended Particulate Samplers
    Q/0214 ZRB010-2017 Comprehensive Ambient Air Particulate Matter Samplers
     


    Comparison
    Feature ZR-3920G High-Vacuum Sampler Conventional Ambient Air Particulate Sampler
    Sampling Targets Fluoride, heavy metals, SVOCs, TSP, PM10, PM2.5 Commonly focused on particulate matter
    Pump Type Imported high-flow, high-vacuum brushless pump Depends on model
    Vacuum Performance >20 kPa load capacity at 50 L/min (product description) Depends on model
    Sampling Heads Interchangeable heads for multiple sampling targets Depends on configuration
    Filter Media Glass fiber, cellulose nitrate, perchloroethylene, PTFE, quartz filters Depends on model
    SVOC Sampling Supports PUF-equipped sampling containers Depends on model
    Environmental Measurement Automatic atmospheric pressure and temperature measurement Depends on model
    Volume Calculation Automatic standard-condition volume calculation Depends on model
    Data Management Built-in storage and USB export in TXT/CSV Depends on model
    Sampling Modes Timed, intermittent, and 24-hour continuous Depends on model
     


    Frequently Asked Questions
    1. What is the ZR-3920G High-Vacuum Sampler used for?
    It is designed for ambient air sampling of fluoride, heavy metals, and SVOCs, while also supporting collection of TSP, PM10, and PM2.5.
    2. Which sampling heads are available?
    Sampling heads can be selected for TSP, PM10, PM2.5, fluoride, airborne heavy metals, and SVOCs. The fluoride sampling head is included as standard.
    3. What filter media can the instrument accommodate?
    It supports glass fiber filters, cellulose nitrate membranes, perchloroethylene membranes, PTFE membranes, and quartz fiber filters. VOC sampling containers equipped with PUF adsorbent resin are also supported.
    4. What is the advantage of the high-vacuum sampling pump?
    The imported brushless pump provides high flow and high vacuum performance, with a stated load capacity exceeding 20 kPa at 50 L/min. This supports sampling applications involving higher flow resistance.
    5. Can the instrument calculate standard sampling volume automatically?
    Yes. It automatically measures atmospheric pressure and temperature and calculates the sampling volume under standard conditions.
    6. Which sampling modes are supported?
    The ZR-3920G supports timed sampling, intermittent sampling, and 24-hour continuous sampling.
    7. How can sampling data be exported?
    Sampling records can be exported through USB in TXT or CSV format. An optional printing module is also available.
    8. Does the instrument support outdoor operation?
    Yes. Its water-resistant, dust-resistant, and impact-resistant construction is designed for operation in rain, snow, dusty conditions, and heavy haze.
    9. Which standards are relevant to ZR-3920G sampling applications?
    Relevant standards include HJ 955-2018 for fluoride sampling, HJ 691-2014 for SVOC sampling, HJ 618-2011 for PM10 and PM2.5 gravimetric measurement, and HJ/T 374-2007 for TSP samplers, among others listed above.


  • Frequently Asked Questions
    1. What is the ZR-3920G High-Vacuum Sampler used for?
    It is designed for ambient air sampling of fluoride, heavy metals, and SVOCs, while also supporting collection of TSP, PM10, and PM2.5.
    2. Which sampling heads are available?
    Sampling heads can be selected for TSP, PM10, PM2.5, fluoride, airborne heavy metals, and SVOCs. The fluoride sampling head is included as standard.
    3. What filter media can the instrument accommodate?
    It supports glass fiber filters, cellulose nitrate membranes, perchloroethylene membranes, PTFE membranes, and quartz fiber filters. VOC sampling containers equipped with PUF adsorbent resin are also supported.
    4. What is the advantage of the high-vacuum sampling pump?
    The imported brushless pump provides high flow and high vacuum performance, with a stated load capacity exceeding 20 kPa at 50 L/min. This supports sampling applications involving higher flow resistance.
    5. Can the instrument calculate standard sampling volume automatically?
    Yes. It automatically measures atmospheric pressure and temperature and calculates the sampling volume under standard conditions.
    6. Which sampling modes are supported?
    The ZR-3920G supports timed sampling, intermittent sampling, and 24-hour continuous sampling.
    7. How can sampling data be exported?
    Sampling records can be exported through USB in TXT or CSV format. An optional printing module is also available.
    8. Does the instrument support outdoor operation?
    Yes. Its water-resistant, dust-resistant, and impact-resistant construction is designed for operation in rain, snow, dusty conditions, and heavy haze.
    9. Which standards are relevant to ZR-3920G sampling applications?
    Relevant standards include HJ 955-2018 for fluoride sampling, HJ 691-2014 for SVOC sampling, HJ 618-2011 for PM10 and PM2.5 gravimetric measurement, and HJ/T 374-2007 for TSP samplers, among others listed above.


     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com