Position: Home > > Environmental monitoring and analysis > Air sampling equipment > Particulate sampler > ZR-3920 Ambient Air Particulate Matter and Gas Sampler

ZR-3920 Ambient Air Particulate Matter and Gas Sampler

Product ID:HQCYklw027

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberZR-3920
    Brand NameQDZHONGRUI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    ZR-3920 Ambient Air Particulate Matter and Gas Sampler
     
    Product Introduction
    The ZR-3920 Ambient Air Particulate Matter and Gas Sampler is designed for comprehensive sampling of particulate matter and harmful gases in ambient and indoor air. It uses the filter membrane weighing method to collect total suspended particles (TSP), PM10, and PM2.5, while the solution absorption method is used to collect various harmful gaseous pollutants.
    The ZR-3920 supports simultaneous three-channel sampling, allowing particulate matter and toxic or harmful gases to be collected at the same time, with independent flow and sampling-time settings for each channel.
    The instrument is available in four configurations:
    •     Model A: Dual-channel heating
    •     Model B: Dual-channel constant temperature
    •     Model E: Constant-temperature fluoride sampling
    •     Model F: Heated fluoride sampling
    With a touchscreen interface, high-performance sampling pumps, environmental monitoring, and automatic data protection, the ZR-3920 is suitable for routine aerosol and air pollution monitoring.

     


    Performance Features
    • Comprehensive Air Sampling: Collects TSP, PM10, PM2.5, and various harmful gases in ambient and indoor air.
    •  Three-Channel Simultaneous Sampling: Supports simultaneous particulate matter and gas sampling, with independently controlled flow rates and sampling times.
    • Multiple Sampling Modes: Supports constant-flow, constant-temperature (constant-temperature models only), timed, intermittent, and 24-hour continuous sampling.
    •   High-Performance Particulate Sampling Pump: Uses an imported, high-flow, high-vacuum, long-life brushless pump. Its load capacity exceeds 9 kPa at 100 L/min.
    • Long Operating Life: The particulate sampling pump supports continuous operation exceeding 20,000 hours at 80% rated load.
    •  Independent Gas Sampling Pumps: Two imported, high-performance, low-noise pumps are provided for toxic and harmful gas sampling.
    • Pump Protection: Built-in airflow blockage and low-flow protection help safeguard the sampling system.
    •   Rugged Outdoor Design: Water-resistant, dust-resistant, and impact-resistant construction supports operation in rain, snow, dusty conditions, and heavy haze.
    • Touchscreen Control: A 5-inch color high-definition touchscreen provides intuitive operation and clear data display.
    • Stable Flow Measurement: High-accuracy electronic flow meters offer corrosion resistance and high-humidity tolerance.
    • Constant-Temperature System: Constant-temperature models use semiconductor temperature control. Heating and cooling temperatures can be controlled independently, with drying tubes and absorption bottles housed inside the insulated chamber.
    •   Data Storage and Export: Built-in large-capacity memory stores instantaneous sampling data. Records can be exported through USB in TXT or CSV format.
    • Environmental Parameter Measurement: Atmospheric pressure and temperature can be measured or entered manually.
    •   Imported Pressure Sensor: Designed for maintenance-free operation without routine calibration.
    •  Power Failure Protection: Sampling data are automatically protected during power interruptions, and sampling resumes when power is restored.
    •  Optional Printing: A portable Bluetooth printer with a built-in lithium battery is available.

     


    Working Principle
    The ZR-3920 uses two complementary sampling methods to collect airborne pollutants.
    Particulate Matter Sampling: Air is drawn through an appropriate filter membrane by a high-flow sampling pump. Particulate matter, including TSP, PM10, and PM2.5, is captured on the filter for subsequent analysis using the filter membrane weighing method.
    Gas Sampling: A separate sampling channel draws ambient or indoor air through an absorption solution. Target gaseous pollutants are collected by the solution for subsequent laboratory analysis.
    The three-channel configuration enables particulate matter and gas samples to be collected simultaneously. Sampling flow and duration can be controlled independently for each channel.

     


    Technical Parameters
    Parameter Specification
    Flow Stability ≤ ±5% within 1 hour
    Flow Range 80–120 L/min
    Operating Duration Under High Flow and Resistance 2–8 hours
    Suction Pressure / Load Capacity 9 kPa at 100 L/min
    Service Life at Maximum Flow and Resistance ≥ 5,000 hours
    Maximum Flow Error Better than ±2.5%
    Sampling Channels Three-channel simultaneous sampling
    Display 5-inch color high-definition touchscreen
    Data Export USB; TXT and CSV formats
    Optional Printer Portable Bluetooth printer with built-in lithium battery
    Note: Model A, B, E, and F have different heating and temperature-control configurations. The constant-temperature sampling function is available only on the corresponding constant-temperature models.
     


    Application Scenarios
    The ZR-3920 is suitable for routine air quality monitoring, environmental sampling, and laboratory analysis in:
    •  Environmental Monitoring: Collection of ambient TSP, PM10, PM2.5, and gaseous pollutant samples.
    •   Indoor Air Quality Testing: Sampling harmful gases and particulate matter in indoor environments.
    •  Occupational Health Monitoring: Air sampling in workplaces and industrial environments.
    • Industrial Pollution Assessment: Monitoring particulate and gaseous pollutants around industrial facilities.
    •   Environmental Protection Agencies: Routine atmospheric aerosol monitoring and pollution investigation.
    •  Scientific Research and Education: Air pollution studies, aerosol research, and environmental science experiments.
    •   Public Health and Safety: Supporting air quality assessments by environmental health and safety departments.

     


    Comparison
    Feature ZR-3920 Conventional Single-Function Sampler
    Sampling Targets TSP, PM10, PM2.5 and harmful gases Often designed for specific sampling targets
    Sampling Channels Three channels operating simultaneously Depends on instrument configuration
    Sampling Methods Filter membrane weighing and solution absorption Usually focused on one sampling method
    Sampling Modes Constant-flow, timed, intermittent, continuous; constant-temperature on applicable models Depends on model
    Flow Range 80–120 L/min Depends on model
    Flow Control Independent flow and time settings for sampling channels Depends on model
    Temperature Control Heating or constant-temperature configurations available Depends on model
    Data Management Built-in storage, USB export, TXT and CSV Depends on model
    Power Failure Protection Automatic data protection and sampling resumption Depends on model
    Outdoor Protection Water-, dust-, and impact-resistant design Depends on model
     


    Frequently Asked Questions
    1. What pollutants can the ZR-3920 collect?
    It collects particulate matter, including TSP, PM10, and PM2.5, as well as various harmful gases in ambient and indoor air.
    2. Can the ZR-3920 collect particulate matter and gases simultaneously?
    Yes. Its three-channel sampling design supports simultaneous collection of particulate matter and toxic or harmful gases. Each channel has independent sampling flow and time controls.
    3. What is the difference between the A, B, E, and F configurations?
    Model A features dual-channel heating, Model B features dual-channel constant-temperature control, Model E is designed for constant-temperature fluoride sampling, and Model F is designed for heated fluoride sampling.
    4. What sampling modes are supported?
    The instrument supports constant-flow, constant-temperature (on applicable models), timed, intermittent, and 24-hour continuous sampling.
    5. What is the sampling flow range?
    The specified flow range is 80–120 L/min, with flow stability of ≤ ±5% within one hour and maximum flow error better than ±2.5%.
    6. Can the instrument operate in harsh outdoor conditions?
    Yes. Its water-resistant, dust-resistant, and impact-resistant design supports sampling in rain, snow, dusty environments, and heavy haze.
    7. How are sampling records exported?
    Sampling data are stored internally and can be exported through USB in TXT or CSV format. An optional portable Bluetooth printer is also available.
    8. What happens if the power supply is interrupted during sampling?
    The instrument automatically protects sampling data during a power interruption and resumes sampling when power is restored.


  • Frequently Asked Questions
    1. What pollutants can the ZR-3920 collect?
    It collects particulate matter, including TSP, PM10, and PM2.5, as well as various harmful gases in ambient and indoor air.
    2. Can the ZR-3920 collect particulate matter and gases simultaneously?
    Yes. Its three-channel sampling design supports simultaneous collection of particulate matter and toxic or harmful gases. Each channel has independent sampling flow and time controls.
    3. What is the difference between the A, B, E, and F configurations?
    Model A features dual-channel heating, Model B features dual-channel constant-temperature control, Model E is designed for constant-temperature fluoride sampling, and Model F is designed for heated fluoride sampling.
    4. What sampling modes are supported?
    The instrument supports constant-flow, constant-temperature (on applicable models), timed, intermittent, and 24-hour continuous sampling.
    5. What is the sampling flow range?
    The specified flow range is 80–120 L/min, with flow stability of ≤ ±5% within one hour and maximum flow error better than ±2.5%.
    6. Can the instrument operate in harsh outdoor conditions?
    Yes. Its water-resistant, dust-resistant, and impact-resistant design supports sampling in rain, snow, dusty environments, and heavy haze.
    7. How are sampling records exported?
    Sampling data are stored internally and can be exported through USB in TXT or CSV format. An optional portable Bluetooth printer is also available.
    8. What happens if the power supply is interrupted during sampling?
    The instrument automatically protects sampling data during a power interruption and resumes sampling when power is restored.


     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com