Position: Home > > Environmental monitoring and analysis > Air sampling equipment > Smoke / flugas sampler > ZR-3702 Integrated Flue Gas Mercury Sampler

ZR-3702 Integrated Flue Gas Mercury Sampler

Product ID:HQCYyq028

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberZR-3702
    Brand NameQINGDAOZHONGRUI
    Payment TermsT/T, paypal,Alibaba.com Pay
    ZR-3702 Integrated Flue Gas Mercury Sampler
     
    Product Introduction
    The ZR-3702 Integrated Flue Gas Mercury Sampler is designed according to HJ917-2017 for the determination of gaseous mercury in flue gas from coal-fired power plants equipped with desulfurization, denitrification, and dust removal systems.
    The sampler integrates the mercury adsorption tube, full-line heating, Peltier cooling and dehumidification, sampling control, and data processing into one compact unit, improving portability and convenience for on-site gaseous mercury sampling.

     


    Applicable Standards
    •  GB/T 16157-1996 — Determination of Particulates and Sampling Methods of Gaseous Pollutants from Exhaust Gas of Stationary Sources
    •   HJ/T 48-1999 — Technical Conditions of Smoke and Dust Samplers
    •  EPA Method 30B — Determination of Total Vapor Phase Mercury Emissions from Coal-Fired Combustion Sources Using Carbon Sorbent Traps
    • HJ917-2017 — Determination of Gaseous Mercury in Exhaust Gas from Stationary Sources by Activated Carbon Adsorption/ Thermal Decomposition Atomic Absorption Spectrometry

     


    Performance Features
    1. Full-Line Heated Sampling: The sampling line is heated throughout, while Peltier cooling and dehumidification at the rear end help prevent condensate from flowing back into the mercury adsorption tube and provide dry-gas sampling volume.
    2.  Integrated Compact Design: The sampling tube and main unit are integrated for reduced size, weight, and improved portability.
    3. Titanium Alloy Heating Components: The adsorption chamber and sampling tube use lightweight, high-temperature-resistant and corrosion-resistant titanium alloy.
    4. Flexible Adsorption Tube Connection: A flexible connection makes adsorption tube replacement easier and helps reduce leakage risks caused by rigid connections.
    5. Dual Independent Sampling Channels: Two built-in high-negative-pressure pumps provide two completely independent mercury adsorption sampling channels with leak-tightness testing.
    6. Automatic Sampling Calculation: Sampling flow and time can be preset. High-precision sensors automatically measure atmospheric pressure and gauge pressure and calculate standard-condition sampling flow and volume.
    7. Power-Failure Protection: Sampling can automatically resume after power is restored.
    8. Optional Wireless Control: Optional GPRS or Bluetooth modules enable operation and monitoring through a smartphone or tablet.
    9. Touchscreen and Keypad: A high-brightness color touchscreen combined with keypad control provides convenient operation over a wide temperature range.
    10. DC Power Input: Supports external lithium battery power for field operation.
    11. Heated Condensate Drainage: The condensate drainage line is heated to help prevent freezing in low-temperature environments.
    12.  RS485 Interface: A standard RS485 communication interface is reserved for connection with compatible instruments.
    13. Built-in Lithium Battery: Supports instrument query, printing, data export, and related functions.
    14. Data Printing and Export: An optional Bluetooth printer can be used for data printing, while USB flash drive export is supported.

     


    Working Principle
    The ZR-3702 collects gaseous mercury from stationary-source flue gas through a mercury adsorption tube. During sampling, the sampling line is heated to maintain appropriate sampling conditions and minimize condensation.
    The sampled gas then passes through the adsorption system, where gaseous mercury is captured. Peltier cooling and dehumidification remove moisture from the gas stream and help prevent condensate from entering the adsorption tube. The instrument continuously monitors sampling conditions such as flow rate and pressure, calculates the standard-condition sampling volume, and records the sampling data for subsequent laboratory analysis.

     


    Technical Specifications
    Parameter Specification
    Product Type Integrated Flue Gas Mercury Sampler
    Sample Gaseous Mercury
    Sampling Temperature 60–160 °C
    Sampling Flow Rate 0.1–1.0 L/min
    Sampling Flow Velocity 0.1–1.0 L/min
    Flow Accuracy ±2.5%
    Sampling Channels 2 independent channels
    Sampling Pump Built-in high-negative-pressure pumps
    Sampling Control Adjustable sampling flow and sampling time
    Pressure/Condition Monitoring Automatic atmospheric and gauge pressure measurement
    Cooling & Dehumidification Peltier rapid cooling and dehumidification
    Communication RS485; optional GPRS/Bluetooth
    Data Export USB flash drive
    Printing Optional Bluetooth printer
    Power AC power / DC external lithium battery
     


    Application Scenarios
    The ZR-3702 gaseous mercury sampler is designed for field sampling and monitoring applications including:
    •   Coal-fired power plant flue gas
    •   Stationary-source gaseous mercury emission monitoring
    •   Flue gas after desulfurization systems
    •   Flue gas after denitrification systems
    •   Flue gas after dust removal systems
    •   Environmental monitoring and emission testing
    •   Laboratory sampling programs based on mercury adsorption tube methods

     


    Comparison with Conventional Mercury Sampling Solutions
    Feature ZR-3702 Integrated Mercury Sampler Conventional Separate Sampling System
    System Design Integrated Multiple separate modules
    Sampling Channels 2 independent channels Depends on configuration
    Sampling Line Heating Full-line heating May require external heating
    Dehumidification Built-in Peltier cooling Often separate equipment
    Flow Calculation Automatic May require manual calculation
    Leak Testing Built-in function Configuration dependent
    Field Portability Compact integrated design More equipment to transport
    Wireless Control Optional GPRS/Bluetooth Usually requires additional devices
    Data Export USB supported Configuration dependent
    Battery Operation DC lithium battery support Depends on system
     


    FAQ
    1.  What does the ZR-3702 measure?
    The ZR-3702 is designed for sampling gaseous mercury in stationary-source flue gas.
    2. What standard is the ZR-3702 designed according to?
    It is designed according to HJ917-2017, and the applicable standards also include GB/T 16157-1996, HJ/T 48-1999, and EPA Method 30B.
    3. What is the sampling temperature range?
    The sampling temperature range is 60–160 °C.
    4. What is the sampling flow range?
    The specified sampling flow range is 0.1–1.0 L/min, with a flow accuracy of ±2.5%.
    5. Does the sampler have multiple sampling channels?
    Yes. It has two independent gaseous mercury adsorption sampling channels, each equipped with a high-negative-pressure sampling pump.
    6. Why does the ZR-3702 use full-line heating?
    Full-line heating helps maintain suitable sampling conditions and reduce condensation during flue gas mercury sampling.
    7. How is moisture removed from the sampled gas?
    The instrument uses Peltier rapid cooling and dehumidification to remove moisture and help prevent condensate from flowing back into the mercury adsorption tube.
    8. Can the ZR-3702 operate on battery power?
    Yes. It provides a DC power interface and supports lithium battery power for field sampling.
    9. Can sampling data be exported?
    Yes. Data can be exported through a USB flash drive, and an optional Bluetooth printer can be used for on-site printing.
    10. Does the ZR-3702 support remote or wireless operation?
    Optional GPRS or Bluetooth modules can be configured for operation and monitoring using a smartphone or tablet.

     
  • FAQ
    1.  What does the ZR-3702 measure?
    The ZR-3702 is designed for sampling gaseous mercury in stationary-source flue gas.
    2. What standard is the ZR-3702 designed according to?
    It is designed according to HJ917-2017, and the applicable standards also include GB/T 16157-1996, HJ/T 48-1999, and EPA Method 30B.
    3. What is the sampling temperature range?
    The sampling temperature range is 60–160 °C.
    4. What is the sampling flow range?
    The specified sampling flow range is 0.1–1.0 L/min, with a flow accuracy of ±2.5%.
    5. Does the sampler have multiple sampling channels?
    Yes. It has two independent gaseous mercury adsorption sampling channels, each equipped with a high-negative-pressure sampling pump.
    6. Why does the ZR-3702 use full-line heating?
    Full-line heating helps maintain suitable sampling conditions and reduce condensation during flue gas mercury sampling.
    7. How is moisture removed from the sampled gas?
    The instrument uses Peltier rapid cooling and dehumidification to remove moisture and help prevent condensate from flowing back into the mercury adsorption tube.
    8. Can the ZR-3702 operate on battery power?
    Yes. It provides a DC power interface and supports lithium battery power for field sampling.
    9. Can sampling data be exported?
    Yes. Data can be exported through a USB flash drive, and an optional Bluetooth printer can be used for on-site printing.
    10. Does the ZR-3702 support remote or wireless operation?
    Optional GPRS or Bluetooth modules can be configured for operation and monitoring using a smartphone or tablet.


     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com