    ZF-621 Vertical Flame Resistance Tester
     
    Product Introduction
    The ZF-621 Vertical Flame Resistance Tester is designed to evaluate the flame resistance of flame-retardant protective clothing and textiles. It is suitable for testing protective garments and fabrics, as well as supporting labor safety certification and production license assessments.
    With automatic ignition, timed burner positioning, and safety protection, the instrument offers convenient operation and reliable testing. It is designed to comply with the following standards:
    •  GB 8965.1-2009 – Protective Clothing: Flame-Retardant Protective Clothing, Part 1
    •  GB/T 5455-1997 – Textiles: Burning Behaviour – Vertical Test Method

     


    Performance Features
    1. Automatic Electric-Wire Ignition: Provides automatic ignition through an electrically heated ignition wire.
    2.  Automatic Burner Positioning: The burner moves into position automatically according to the preset timing.
    3.  Push-Pull Specimen Holder: An automatic push-pull fixture secures the test specimen.
    4.  Adjustable Flame Height: Flame height can be adjusted and checked using the supplied flame-height measuring device.
    5. Gas Leakage Protection: A high-sensitivity combustible gas leak detector triggers an alarm and automatically shuts off the gas supply if a leak is detected.
    6. Flexible Gas Supply: Compatible with propane, butane, or liquefied petroleum gas (LPG).
    7.  Benchtop Installation: Designed for placement on a laboratory workbench or desktop.

     


    Working Principle
    The specimen is secured vertically in the automatic push-pull holder. The burner is automatically moved to the preset test position, and the electric-wire ignition system ignites the gas flame. The specimen is exposed to the flame for the preset ignition period. After flame exposure, the instrument can measure afterflame time and flame-retardant time using its built-in timers.
    The adjustable flame height and automatic burner positioning help standardize the test procedure, while the gas leakage alarm and automatic shutoff improve operational safety.

     


    Technical Parameters
    Parameter Specification
    Burner movement motor power 10 W
    Ignition timer range 0–99.99 s, freely adjustable
    Standard ignition time 12 s
    Afterflame time timer 0–99.99 s
    Flame-retardant time timer 0–99.99 s
    Timer accuracy ±0.01 s
    Gas supply Propane, butane, or LPG
    Installation Benchtop
    Overall dimensions 715 × 330 × 910 mm
     


    Application Scenarios
    •  Flame resistance testing of protective clothing
    •  Evaluation of flame-retardant fabrics and textiles
    •  Quality control in textile and protective clothing manufacturing
    •  Laboratory testing for occupational safety products
    • Testing support for labor safety certification and production license assessments

     


    Comparison with Conventional Manual Testing
    Feature ZF-621 Conventional Manual Setup
    Ignition Automatic electric-wire ignition Depends on the test setup
    Burner positioning Automatic timed positioning May require manual positioning
    Specimen holding Automatic push-pull holder Depends on fixture design
    Flame height Adjustable, with measuring device Depends on available equipment
    Timing Digital timing with ±0.01 s accuracy Depends on timing equipment
    Gas safety Leak alarm and automatic gas shutoff Depends on safety configuration
     


    Frequently Asked Questions
    1.  What is the ZF-621 Vertical Flame Resistance Tester used for?
    It is used to evaluate the flame resistance of protective clothing and flame-retardant textile materials.
    2.  Which testing standards does the instrument support?
    The instrument is designed to comply with GB 8965.1-2009 and GB/T 5455-1997.
    3.  What gas can be used with the ZF-621?
    The instrument can use propane, butane, or liquefied petroleum gas (LPG).
    4.  Is the ignition process automatic?
    Yes. The instrument uses an automatic electric-wire ignition system.
    5.  Can the flame height be adjusted?
    Yes. The flame height is adjustable, and a flame-height measuring device is provided.
    6.  What is the standard ignition time?
    The standard ignition time is 12 seconds. The timer can be freely set from 0 to 99.99 seconds.
    7.  How accurately can the instrument measure afterflame and flame-retardant times?
    Both timers have a range of 0–99.99 seconds and an accuracy of ±0.01 seconds.
    8.  What safety features are included?
    A high-sensitivity combustible gas leakage detector provides an alarm and automatically shuts off the gas supply when a leak is detected.


  • Frequently Asked Questions
    1. What is the ZF-621 Vertical Flame Resistance Tester used for?
    It is used to evaluate the flame resistance of protective clothing and flame-retardant textile materials.
    2. Which testing standards does the instrument support?
    The instrument is designed to comply with GB 8965.1-2009 and GB/T 5455-1997.
    3. What gas can be used with the ZF-621?
    The instrument can use propane, butane, or liquefied petroleum gas (LPG).
    4. Is the ignition process automatic?
    Yes. The instrument uses an automatic electric-wire ignition system.
    5. Can the flame height be adjusted?
    Yes. The flame height is adjustable, and a flame-height measuring device is provided.
    6. What is the standard ignition time?
    The standard ignition time is 12 seconds. The timer can be freely set from 0 to 99.99 seconds.
    7. How accurately can the instrument measure afterflame and flame-retardant times?
    Both timers have a range of 0–99.99 seconds and an accuracy of ±0.01 seconds.
    8. What safety features are included?A high-sensitivity combustible gas leakage detector provides an alarm and automatically shuts off the gas supply when a leak is detected.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com