Position: Home > > Lab general equipment > Sample preparation and digestion > Microwave digestion > XT-9900N Intelligent Microwave Digestion/Extraction System

XT-9900N Intelligent Microwave Digestion/Extraction System

Product ID:SYZXwbxj006

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberXT-9900N
    Brand NameSHXINTUO
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    XT-9900N Intelligent Microwave Digestion/Extraction System
    Product Introduction
    The XT-9900N Intelligent Microwave Digestion/Extraction System is a high-performance laboratory sample preparation instrument designed for microwave digestion and extraction. It combines real non-burst variable-frequency microwave power control with dual-CPU monitoring to achieve accurate, automated regulation of temperature, pressure, and microwave input power.
    With a maximum working temperature of 250°C, non-contact pressure control up to 5 MPa, and a pressure endurance of 6 MPa, the XT-9900N supports demanding sample preparation procedures while maintaining high operational safety.
    Its programmable multi-step methods, intelligent pressure control, microwave “Shock” protection, abnormal-noise detection, and multiple pressure-relief mechanisms make it suitable for laboratories requiring reproducible and automated digestion or extraction workflows.

     

    Performance Features
    •  Variable-frequency microwave control: Real non-burst microwave power adjustment from 50–100% at 2450 MHz.
    •  Dual-CPU monitoring: Independent interactive monitoring enables precise temperature and pressure control.
    •  Automatic power adjustment: Microwave input power is automatically adjusted according to programmed conditions.
    •  High-temperature and high-pressure operation: Supports up to 250°C and 5 MPa controlled pressure.
    •  Programmable methods: Stores up to 9 programs, with 9 programmable steps per method.
    •  Microwave “Shock” protection: Automatically interrupts microwave input when the pressure rise rate reaches ≥0.2 MPa/s and resumes operation after pressure decreases.
    •  Automatic pressure calibration: Zero and full-range adjustment can be performed automatically.
    •  Intelligent fault diagnosis: Detects abnormal conditions and displays diagnostic information in real time.
    •  Remote operation: Supports remote control for convenient and safer operation.
    •  Multiple safety protections: Includes overpressure, overheating, abnormal-noise, emergency-stop, pressure-relief, and protective-cover mechanisms.
    •  Easy operation: Menu-based interface and automatic system self-check simplify method setup and routine operation.

     

    Working Principle
    The XT-9900N uses 2450 MHz microwave energy to heat samples rapidly and uniformly inside a sealed digestion vessel. Microwave power is continuously regulated according to programmed temperature and pressure conditions.
    A dual-CPU control system continuously monitors operating parameters and automatically adjusts microwave input power. Temperature can be controlled up to 250°C, while non-contact pressure measurement and automatic pressure control maintain the programmed reaction conditions.
    During operation, the system monitors the pressure rise rate. If pressure increases too rapidly, the microwave source is automatically interrupted by the microwave “Shock” protection function. Once pressure returns to a safe level, microwave input can automatically resume.
    The combination of microwave heating, programmable multi-stage control, automatic pressure regulation, and integrated safety protection enables efficient and reproducible sample digestion and extraction.

     

    Technical Parameters
    Parameter Specification
    Microwave Frequency 2450 MHz
    Microwave Power 1000 W, adjustable 50–100%
    Microwave Power Control Real non-burst variable-frequency adjustment
    Temperature Range Up to 250°C
    Temperature Accuracy ±1°C
    Pressure Control Range 0.1–5 MPa
    Pressure Accuracy ±0.01 MPa
    Maximum Pressure Endurance 6 MPa / 900 psi
    Pressure Control Non-contact automatic control
    Pressure Rise Protection Automatic cutoff at ≥0.2 MPa/s
    Operation Programs 9 programs
    Steps per Program 9 steps/phases
    Step Time 1–9999 s
    Control System Dual-CPU monitoring
    Microwave “Shock” Function Standard
    Power Supply AC 220V ±10%, 50 Hz
    Input Power 1360 W
    Furnace Chamber Volume 34 L
    External Dimensions 570 × 510 × 520 mm
    Weight 25 kg
     

    Safety Protection System
    The XT-9900N incorporates multiple safety mechanisms for high-pressure microwave sample preparation:
    1. High-pressure external vessel: PSF vessel with PPS liner, rated to 6 MPa.
    2. Overheating protection: Automatically warns and suspends microwave radiation when overheating is detected.
    3. Abnormal-noise detection: Detects unusual chamber noise and automatically stops microwave generation.
    4. Overpressure protection: Automatic pressure matching, pressure-rise limitation, and warning.
    5. Emergency suspension: Operation can be stopped using the emergency button or remote control.
    6. Dual pressure relief: Air-bleed hole and bursting-film mechanisms provide additional pressure relief.
    7. High-strength protective cover: PC protective cover helps shield operators during operation.

     

    Applications
    •  Environmental analysis: Digestion of soil, sediment, sludge, water-related samples, and environmental materials.
    •  Food and agricultural analysis: Sample preparation for elemental and chemical analysis of food and agricultural products.
    •  Pharmaceutical research: Microwave-assisted sample digestion and extraction for pharmaceutical analysis.
    •  Geological and mineral analysis: Rapid preparation of geological, mineral, and related solid samples.
    •  Chemical laboratories: Efficient digestion and extraction of difficult or complex samples.
    •  Metals and materials analysis: Sample preparation before elemental and materials characterization.
    •  Scientific research: Programmable multi-step microwave digestion and extraction for method development.

     

    XT-9900N vs. Conventional Digestion/Extraction Methods
    Feature XT-9900N Microwave Digestion/Extraction Conventional Heating Digestion
    Heating Method Microwave Conventional thermal heating
    Temperature Control Automatic, up to 250°C Typically slower thermal response
    Pressure Control Automatic, up to 5 MPa Often limited or manual
    Power Adjustment Variable-frequency, automatic Usually manual or fixed
    Multi-Step Programs 9 programs × 9 steps Often requires manual intervention
    Processing Efficiency Rapid microwave heating Generally slower
    Safety Monitoring Multi-level intelligent protection Depends on equipment configuration
    Remote Operation Supported Usually limited
    Fault Diagnosis Automatic detection and display Often requires manual inspection
     

    Frequently Asked Questions (FAQ)
    1. What is the XT-9900N used for?
    The XT-9900N is designed for microwave digestion and extraction in laboratory sample preparation, particularly for samples requiring controlled high-temperature and high-pressure treatment.
    2. What is the maximum operating temperature?
    The maximum working temperature is 250°C, with a temperature control accuracy of ±1°C.
    3. What is the maximum controlled pressure?
    The automatic pressure control range is 0.1–5 MPa, while the digestion vessel has a maximum pressure endurance of 6 MPa.
    4. How many methods can the XT-9900N store?
    The system can store 9 operation programs, and each program contains up to 9 programmable steps. Each step can be set from 1 to 9999 seconds.
    5. What is the microwave frequency?
    The system operates at 2450 MHz, with microwave power up to 1000 W and adjustable output from 50–100%.
    6. What is the microwave “Shock” function?
    The microwave “Shock” function protects the system against rapid pressure increases. When the pressure rise rate reaches ≥0.2 MPa/s, microwave generation is automatically interrupted and can resume after the pressure decreases.
    7. How does the XT-9900N protect operators?
    It combines overheating protection, abnormal-noise detection, automatic overpressure protection, emergency stop, dual pressure-relief mechanisms, and a high-strength protective cover.
    8. Can the XT-9900N be operated remotely?
    Yes. The system supports remote control, allowing convenient operation and emergency suspension when required.
    9. Is the system suitable for automated sample preparation?
    Yes. Programmable multi-step operation, automatic temperature and pressure regulation, automatic microwave power adjustment, self-checking, and fault diagnosis support highly automated sample preparation workflows.

     
  • Frequently Asked Questions (FAQ)
    1. What is the XT-9900N used for?
    The XT-9900N is designed for microwave digestion and extraction in laboratory sample preparation, particularly for samples requiring controlled high-temperature and high-pressure treatment.
    2. What is the maximum operating temperature?
    The maximum working temperature is 250°C, with a temperature control accuracy of ±1°C.
    3. What is the maximum controlled pressure?
    The automatic pressure control range is 0.1–5 MPa, while the digestion vessel has a maximum pressure endurance of 6 MPa.
    4. How many methods can the XT-9900N store?
    The system can store 9 operation programs, and each program contains up to 9 programmable steps. Each step can be set from 1 to 9999 seconds.
    5. What is the microwave frequency?
    The system operates at 2450 MHz, with microwave power up to 1000 W and adjustable output from 50–100%.
    6. What is the microwave “Shock” function?
    The microwave “Shock” function protects the system against rapid pressure increases. When the pressure rise rate reaches ≥0.2 MPa/s, microwave generation is automatically interrupted and can resume after the pressure decreases.
    7. How does the XT-9900N protect operators?
    It combines overheating protection, abnormal-noise detection, automatic overpressure protection, emergency stop, dual pressure-relief mechanisms, and a high-strength protective cover.
    8. Can the XT-9900N be operated remotely?
    Yes. The system supports remote control, allowing convenient operation and emergency suspension when required.
    9. Is the system suitable for automated sample preparation?
    Yes. Programmable multi-step operation, automatic temperature and pressure regulation, automatic microwave power adjustment, self-checking, and fault diagnosis support highly automated sample preparation workflows.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com