WZS-182E Turbidity Meter

Product ID:HSCzd035

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberWZS-182E
    Brand NameSHLEICI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    WZS-182E Turbidity Meter
    Product Introduction
    The WZS-182E Turbidity Meter is designed for laboratory water quality analysis and routine turbidity measurement. Equipped with a tungsten-halogen light source operating across the 400–600 nm wavelength range, it supports measurement methods specified for EPA 180.1 and HJ 1075 applications.
    The instrument offers selectable scattered-light and scattered-light/transmitted-light methods, automatic range switching, and multiple turbidity units, including NTU, FNU, and EBC. Its 5.7-inch color LCD provides a clear operating interface, while built-in storage for up to 1,000 records, USB and RS232 interfaces, and support for PC software and printers facilitate data management and reporting.

     

    Performance Features
    •  Large Color Display: 5.7-inch color LCD for convenient operation and result viewing.
    •  Tungsten-Halogen Light Source: Operates at 400–600 nm and is specified to meet EPA 180.1 and HJ 1075 requirements.
    • Selectable Measurement Methods: Switch between scattered-light and scattered-light/transmitted-light methods.
    • Automatic Range Switching: Selects the appropriate measurement range automatically.
    •   Multiple Measurement Units: Supports NTU, FNU, and EBC.
    •  Flexible Measurement Modes: Offers standard and average measurement modes.
    • Convenient Calibration: Supports zero-point calibration and single-point or continuous multi-point turbidity calibration.
    •  Built-In Calibration Data: Includes stored calibration curves and functions for restoring factory zero-point and calibration values.
    •  Data Storage and Management: Stores up to 1,000 measurement records, with functions to review, delete, transfer, and print data.
    • Multiple Connectivity Options: USB and RS232 interfaces support connection to compatible PC software and printers.

     

    Working Principle
    The WZS-182E measures turbidity by analyzing how suspended particles interact with light passing through a water sample. It supports two selectable methods: scattered-light measurement and a combined scattered-light/transmitted-light method.
    The instrument's optical system detects changes in light scattering and transmission caused by particles in the sample and converts the measured signals into turbidity readings. Automatic range switching supports different turbidity levels, while calibration functions help maintain measurement consistency.
    The selectable NTU, FNU, and EBC units provide flexibility for different testing workflows. The appropriate measurement method and unit should be selected according to the applicable test standard and laboratory procedure.

     

    Technical Parameters
    Parameter Specification
    Model WZS-182E
    Instrument Type Turbidity meter
    Display 5.7-inch color LCD
    Light Source Tungsten-halogen lamp
    Wavelength Range 400–600 nm
    Referenced Standards USEPA 180.1 and HJ 1075
    Measurement Methods Scattered light; scattered light and transmitted light
    Measurement Range 0.00–9.99 NTU; 10.0–99.9 NTU; 100–500 NTU
    Maximum Specified Range 500 NTU
    Measurement Units NTU, FNU, EBC
    Measurement Modes Standard and average
    Range Selection Automatic
    Calibration Zero-point; single-point or continuous multi-point turbidity calibration
    Calibration Data Built-in calibration curves; factory calibration restoration
    Data Storage Up to 1,000 records
    Data Functions Review, delete, transfer, and print
    Communication Interfaces USB, RS232
    External Connectivity Compatible PC software and printer support
    Indication Error ±6%
    Repeatability ≤0.5%
    Note: The supplied specifications do not state the repeatability unit or provide details such as dimensions, power supply, and operating environment. Confirm these details and the applicable measurement method with the manufacturer before purchase.
     

    Application Scenarios
    • Drinking Water Laboratories: Routine turbidity testing in water quality assessment.
    •  Environmental Monitoring: Analysis of turbidity in surface water and other environmental samples.
    •  Water Treatment Plants: Monitoring turbidity during filtration and treatment processes.
    •  Wastewater Laboratories: Evaluating turbidity changes during wastewater treatment.
    •   Industrial Water Quality Control: Testing process water and circulating water.
    •  Research and Education: Laboratory studies involving suspended particles and water clarity.
    •  Third-Party Testing Laboratories: Routine sample analysis, data recording, and report preparation.

     

    WZS-182E vs. Portable Turbidity Meters
    Comparison Item WZS-182E Turbidity Meter Typical Portable Turbidity Meter
    Display 5.7-inch color LCD Usually a compact display
    Light Source Tungsten-halogen, 400–600 nm Depends on the model
    Measurement Methods Scattered light and combined scattered/transmitted light Depends on the model
    Measurement Units NTU, FNU, EBC Depends on the model
    Maximum Stated Range 500 NTU Depends on the model
    Data Storage Up to 1,000 records Depends on the model
    Interfaces USB and RS232 Depends on the model
    PC and Printer Support Supported with compatible equipment Depends on the model
    Best Suited For Laboratory testing and data management Field testing and mobile sampling
    This comparison describes typical instrument configurations. Actual portability, accuracy, and functionality depend on the specific model.
     

    Frequently Asked Questions
    1. What is the measurement range of the WZS-182E?
    The WZS-182E covers three stated ranges: 0.00–9.99 NTU, 10.0–99.9 NTU, and 100–500 NTU, with automatic range switching.
    2. Which light source does the instrument use?
    It uses a tungsten-halogen light source operating across 400–600 nm, specified for applications referencing USEPA 180.1 and HJ 1075.
    3. Which turbidity measurement methods are available?
    The instrument supports scattered-light measurement and a combined scattered-light/transmitted-light method. Select the method appropriate to the relevant standard and sample.
    4. Can the WZS-182E display different turbidity units?
    Yes. It supports NTU, FNU, and EBC units to accommodate different measurement workflows.
    5. What calibration functions are available?
    The instrument supports zero-point calibration and single-point or continuous multi-point turbidity calibration. It also includes built-in calibration curves and a function for restoring factory calibration values.
    6. How many measurement records can it store?
    The WZS-182E can store up to 1,000 records. Stored data can be reviewed, deleted, transferred, and printed.
    7. Can the turbidity meter connect to a computer?
    Yes. It has USB and RS232 interfaces and supports connection to compatible PC software for data transfer and management.
    8. Can the WZS-182E connect to a printer?
    Yes. Printer connectivity is supported. Confirm printer compatibility, connection requirements, and whether the printer is included in the purchase package.
    9. What is the stated measurement accuracy?
    The specified indication error is ±6%, and repeatability is ≤0.5%. The repeatability unit and test conditions should be confirmed with the manufacturer.
     

     
     
     
     
  • Frequently Asked Questions
    1. What is the measurement range of the WZS-182E?
    The WZS-182E covers three stated ranges: 0.00–9.99 NTU, 10.0–99.9 NTU, and 100–500 NTU, with automatic range switching.
    2. Which light source does the instrument use?
    It uses a tungsten-halogen light source operating across 400–600 nm, specified for applications referencing USEPA 180.1 and HJ 1075.
    3. Which turbidity measurement methods are available?
    The instrument supports scattered-light measurement and a combined scattered-light/transmitted-light method. Select the method appropriate to the relevant standard and sample.
    4. Can the WZS-182E display different turbidity units?
    Yes. It supports NTU, FNU, and EBC units to accommodate different measurement workflows.
    5. What calibration functions are available?
    The instrument supports zero-point calibration and single-point or continuous multi-point turbidity calibration. It also includes built-in calibration curves and a function for restoring factory calibration values.
    6. How many measurement records can it store?
    The WZS-182E can store up to 1,000 records. Stored data can be reviewed, deleted, transferred, and printed.
    7. Can the turbidity meter connect to a computer?
    Yes. It has USB and RS232 interfaces and supports connection to compatible PC software for data transfer and management.
    8. Can the WZS-182E connect to a printer?
    Yes. Printer connectivity is supported. Confirm printer compatibility, connection requirements, and whether the printer is included in the purchase package.
    9. What is the stated measurement accuracy?
    The specified indication error is ±6%, and repeatability is ≤0.5%. The repeatability unit and test conditions should be confirmed with the manufacturer.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com