    WN900 Landfill Gas Detector
     
    Product Introduction
    The WN900 Landfill Gas Detector is an intelligent, pump-operated multi-gas analyzer designed for landfill gas monitoring, industrial hygiene, and other gas detection applications. Its flexible sensor configuration supports up to four gas sensors, including an optional nondispersive infrared (NDIR) sensor for carbon dioxide detection.
    Depending on the selected configuration, the WN900 can monitor gases such as methane (CH₄), oxygen (O₂), carbon dioxide (CO₂), hydrogen sulfide (H₂S), combustible gases, and other toxic gases. It also measures ambient temperature and humidity.
    Equipped with a built-in sampling pump, a large color touchscreen, audible and visual alarms, and internal data storage for up to 256 records, the WN900 supports field inspections and routine gas safety monitoring.

     


    Performance Features
    •  Flexible multi-gas configuration: Supports up to four gas sensors, including CO₂, depending on the selected configuration.
    •  NDIR carbon dioxide detection: Uses infrared sensing technology for CO₂ measurement.
    •  Built-in sampling pump: Draws gas samples from remote locations through a sampling line.
    • Temperature and humidity monitoring: Measures environmental temperature and relative humidity alongside gas concentrations.
    •  Color touchscreen: Provides a clear display and convenient operation.
    •  Audible and visual alarms: Alerts users when configured alarm conditions are triggered.
    •  Internal data storage: Stores up to 256 records.
    •  USB data transfer: Connects to a computer for data access.
    •  Automatic unit conversion: Displays gas concentration in ppm and mg/m³, with automatic conversion where supported.
    •  Self-check function: Checks the display, battery, sensors, and audible and visual alarm functions at startup or when required.
    •  Long operating time: Approximately 200 hours of continuous operation under the stated conditions.

     


    Working Principle
    The WN900 draws gas from the sampling point into the instrument using its built-in pump. The installed sensors measure the concentrations of the selected gases.
    The NDIR sensor measures carbon dioxide by detecting infrared absorption associated with CO₂. Other gases are measured using their corresponding configured sensors. Environmental temperature and humidity are also monitored.
    The instrument displays the measurement results on its color touchscreen and can trigger audible and visual alarms according to the configured alarm thresholds. Measurement records can be stored internally and transferred to a computer through the USB interface.

     


    Technical Specifications
    Parameter Specification
    Model WN900
    Instrument type Pump-operated multi-gas detector
    Maximum sensor configuration Up to 4 gas sensors
    Methane (CH₄), LEL 0–100% LEL
    Methane resolution 1% LEL
    Oxygen (O₂) range 0–30%
    Oxygen resolution 0.1%
    Carbon dioxide (CO₂) range 0–20,000 ppm
    Carbon dioxide resolution 10 ppm
    Hydrogen sulfide (H₂S) range 0–500 ppm
    Hydrogen sulfide resolution 1 ppm
    CO₂ sensing technology NDIR
    CO₂ sensor service life Approximately 7 years
    Other sensor service life Approximately 30 months
    Sampling method Built-in pump
    Display Large color LCD touchscreen
    Alarm Audible and visual
    Data storage Up to 256 records
    Data interface USB
    Display units ppm and mg/m³, with automatic conversion
    Temperature monitoring Supported
    Humidity monitoring Supported
    Continuous battery operating time Approximately 200 hours
    Charging accessory Charger included
    Operating temperature −10 to 45°C
    Operating humidity 5–90% RH
    Note: The stated gas ranges and resolutions apply to the listed sensors. Confirm the actual sensor combination, methane measurement basis, alarm settings, and sampling-line configuration when ordering.
     


    Application Scenarios
    •  Landfill gas monitoring: Measuring methane, carbon dioxide, oxygen, and hydrogen sulfide in landfill environments.
    • Waste management facilities: Supporting gas inspections around waste treatment and disposal operations.
    •  Industrial hygiene: Checking selected toxic, combustible, and oxygen-related gas hazards in workplaces.
    • Environmental monitoring: Assessing gas concentrations at selected environmental sampling points.
    • Confined-space preparation: Supporting preliminary atmospheric assessment when used within an appropriate confined-space safety procedure.
    •  Routine safety inspections: Recording gas measurements and transferring data for reporting and review.

     


     WN900 vs. Conventional Single-Gas Detectors
    Comparison Item WN900 Multi-Gas Detector Conventional Single-Gas Detector
    Gas monitoring Configurable for up to four gas sensors Usually designed for one target gas
    CO₂ measurement NDIR sensor option Depends on the detector type
    Sampling Built-in pump May use diffusion or pumped sampling
    Environmental measurements Temperature and humidity Depends on the model
    Display Color touchscreen Varies by instrument
    Alarms Audible and visual Depends on the model
    Data storage Up to 256 records Depends on the model
    Data transfer USB interface Depends on the model
    Best suited for Multi-gas field inspection and landfill monitoring Monitoring a specific gas
     


    Frequently Asked Questions
    Q1: What gases can the WN900 detect?
    Depending on sensor configuration, it can detect methane, oxygen, carbon dioxide, hydrogen sulfide, combustible gases, and other toxic gases. The instrument supports up to four gas sensors.
    Q2: How does the WN900 measure carbon dioxide?
    It uses a nondispersive infrared (NDIR) sensor to measure CO₂ concentrations from 0 to 20,000 ppm, with a stated resolution of 10 ppm.
    Q3: Does the detector have a built-in sampling pump?
    Yes. The pump draws gas through a sampling line, allowing sampling from locations away from the instrument. The achievable sampling distance depends on the tubing, flow rate, and system configuration.
    Q4: Can the WN900 measure temperature and humidity?
    Yes. In addition to gas detection, it monitors environmental temperature and relative humidity.
    Q5: How many records can the instrument store?
    The WN900 can store up to 256 records internally and supports USB data transfer to a computer.
    Q6: What is the battery operating time?
    The stated continuous operating time is approximately 200 hours. Actual runtime may vary with sensor configuration, pump operation, alarm activity, and battery condition.
    Q7: How long do the sensors last?
    The specified service life is approximately seven years for the CO₂ sensor and 30 months for other sensors. Actual service life depends on operating conditions, calibration, maintenance, and exposure to contaminants.
    Q8: Does the WN900 measure methane in percent or ppm?
    The supplied specification lists methane as 0–100% LEL with a resolution of 1% LEL. This is a measurement relative to the lower explosive limit, not a direct methane volume percentage. Confirm the display format and calibration gas for the selected configuration.
    Q9: Is the WN900 suitable for confined-space entry?
    It can support atmospheric assessment when configured for the relevant hazards, but it should not be treated as sufficient for entry approval on its own. Verify sensor suitability, calibration, alarm settings, sampling procedures, and applicable safety requirements before use.


  • Frequently Asked Questions
    Q1: What gases can the WN900 detect?
    Depending on sensor configuration, it can detect methane, oxygen, carbon dioxide, hydrogen sulfide, combustible gases, and other toxic gases. The instrument supports up to four gas sensors.
    Q2: How does the WN900 measure carbon dioxide?
    It uses a nondispersive infrared (NDIR) sensor to measure CO₂ concentrations from 0 to 20,000 ppm, with a stated resolution of 10 ppm.
    Q3: Does the detector have a built-in sampling pump?
    Yes. The pump draws gas through a sampling line, allowing sampling from locations away from the instrument. The achievable sampling distance depends on the tubing, flow rate, and system configuration.
    Q4: Can the WN900 measure temperature and humidity?
    Yes. In addition to gas detection, it monitors environmental temperature and relative humidity.
    Q5: How many records can the instrument store?
    The WN900 can store up to 256 records internally and supports USB data transfer to a computer.
    Q6: What is the battery operating time?
    The stated continuous operating time is approximately 200 hours. Actual runtime may vary with sensor configuration, pump operation, alarm activity, and battery condition.
    Q7: How long do the sensors last?
    The specified service life is approximately seven years for the CO₂ sensor and 30 months for other sensors. Actual service life depends on operating conditions, calibration, maintenance, and exposure to contaminants.
    Q8: Does the WN900 measure methane in percent or ppm?
    The supplied specification lists methane as 0–100% LEL with a resolution of 1% LEL. This is a measurement relative to the lower explosive limit, not a direct methane volume percentage. Confirm the display format and calibration gas for the selected configuration.
    Q9: Is the WN900 suitable for confined-space entry?
    It can support atmospheric assessment when configured for the relevant hazards, but it should not be treated as sufficient for entry approval on its own. Verify sensor suitability, calibration, alarm settings, sampling procedures, and applicable safety requirements before use.



     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com