| Parameter | WH81 | WH82 |
| Measurement Principle | Magnetic induction (F-type probe) | Magnetic induction (F-type probe) and eddy current (NF-type probe) |
| Measurement Range | 0–1250 μm | Not specified |
| Accuracy Error | Zero calibration: ±(1 + 3% H); two-point calibration: ±[(1%–3% H) + 1.5] | Not specified |
| Measurement Units | μm / mil | Not specified |
| Power Supply | 2 × AA batteries | Not specified |
| Operating Temperature | 0–40°C | Not specified |
| Operating Humidity | ≤85% RH | Not specified |
| Minimum Substrate Size | 10 × 10 mm | Not specified |
| Minimum Curvature Radius | 5 mm convex / 5 mm concave | Not specified |
| Minimum Substrate Thickness | 0.4 mm | Not specified |
| Weight | 99 g | Not specified |
| Dimensions | 110 × 65 × 30 mm | Not specified |
| Comparison Item | WH81 | WH82 |
| Measurement Methods | Magnetic induction | Magnetic induction + eddy current |
| Probe Type | F-type | F-type and NF-type |
| Ferrous Substrates | Yes | Yes |
| Non-Ferrous Substrates | Not supported by the specified magnetic method | Supported with eddy current measurement |
| Typical Applications | Non-magnetic coatings on magnetic metals | Non-magnetic coatings on magnetic metals and non-conductive coatings on non-magnetic metals |
| Measurement Range | 0–1250 μm | Not specified |
| Best-Suited Use | Basic coating thickness inspection | More versatile coating inspection across different metal substrates |