Position: Home > > Life science instrument and equipment > Clinical test instrument and equipment > Microplate Reader > WD-2102B Non-Medical Automatic Microplate Reader

WD-2102B Non-Medical Automatic Microplate Reader

Product ID:SHLCmby031

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberWD-2102B
    Brand NameBJLIUYI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    WD-2102B Non-Medical Automatic Microplate Reader
     
    Product Introduction
    The WD-2102B Non-Medical Automatic Microplate Reader is a computer-controlled laboratory microplate reader designed for efficient absorbance measurement and analysis. Measurement, data analysis, display and printing functions are integrated through dedicated microcomputer software, providing convenient operation and flexible data processing.
    The instrument features an 8-channel vertical optical system, imported detector, industrial-grade color LCD touchscreen and center-positioning function. It supports endpoint, two-point and kinetic analysis, as well as single- and dual-wavelength measurement modes.
    A dedicated inhibition-rate measurement module is available for food safety testing applications.

     


    Performance Features
    •   8-Channel Optical System: Uses an 8-channel vertical optical path with an imported detector.
    •   Wide Wavelength Range: Supports measurements from 400 to 800 nm.
    •  Touchscreen Operation: 8-inch color LCD touchscreen with visualized microplate layout.
    • Center Positioning: Provides a center-positioning function for plate measurement.
    •  Multiple Measurement Modes: Supports endpoint, two-point and kinetic analysis.
    •Single/Dual Wavelength: Flexible single- and dual-wavelength measurement modes.
    •  Adjustable Plate Shaking: Three shaking speed levels with adjustable shaking time from 0–255 s.
    • Flexible Cut-Off Calculation: Open Cut-Off judgment formula allows users to enter their own calculation formula.
    • Food Safety Testing: Optional inhibition-rate measurement module supports food safety applications.
    • Multiple Calculation Models: Supports linear, logarithmic, quadratic, cubic, exponential, power, absorbance-percentage concentration logarithmic and four-parameter equations.
    •  Large Data Capacity: Stores up to 100 programs and 100,000 sample results.
    •   Wide-Voltage Power Supply: AC100–240 V, 50–60 Hz.

     


    Working Principle
    The WD-2102B measures the optical absorbance of samples in microplate wells. A DC12V/22W imported halogen-tungsten lamp provides the light source, while the 8-channel vertical optical system directs light through the selected microplate wells to the detector.
    The instrument measures absorbance within the selected wavelength range and processes the data using the selected analytical method. Depending on the application, results can be calculated using endpoint, two-point, kinetic, single-wavelength or dual-wavelength methods.
    The software can further process measurement data using different mathematical models, including linear and nonlinear equations.

     


    Technical Specifications
    Parameter Specification
    Model WD-2102B
    Product Type Non-medical automatic microplate reader
    Light Source DC12V 22W imported halogen-tungsten lamp
    Optical System 8-channel vertical optical path
    Wavelength Range 400–800 nm
    Standard Filters 405 (or 412), 450, 492, 630 nm
    Optional Filters Other wavelengths; up to 10 filters can be installed
    Reading Range 0–4.000 Abs
    Resolution 0.001 Abs
    Indication Error ≤±0.01 Abs
    Stability ≤±0.003 Abs
    Repeatability ≤0.3%
    Plate Shaking 3 speed levels
    Shaking Time 0–255 s
    Display 8-inch color LCD
    Operation Touchscreen
    Measurement Modes Endpoint, two-point, kinetic
    Wavelength Modes Single and dual wavelength
    Cut-Off User-defined Cut-Off formula
    Data Storage 100 programs; 100,000 sample results
    Analysis Models Absorbance, threshold, linear, logarithmic, quadratic, cubic, exponential, power, absorbance%-concentration logarithmic, 4-parameter equation
    Food Safety Function Inhibition-rate measurement module
    Power Supply AC100–240 V, 50–60 Hz
    Net Weight Approx. 11 kg
    Dimensions 433 × 320 × 308 mm
     


    Application Scenarios
    The WD-2102B can be used for:
    • ELISA and Microplate Testing: Absorbance measurement and quantitative analysis of microplate samples.
    • Food Safety Testing: Applications using the optional inhibition-rate measurement module.
    •   Biochemical Research: Routine absorbance-based microplate analysis.
    •  Laboratory Testing: Single- and dual-wavelength measurements across a broad 400–800 nm range.
    •   Kinetic Analysis: Monitoring absorbance changes over time.
    •  Research and Quality Control: Program storage and large-capacity sample-result management.

     


    Comparison: WD-2102B vs. Basic Microplate Reader
    Feature WD-2102B Basic Microplate Reader
    Optical System 8-channel vertical optical system Depends on model
    Wavelength Range 400–800 nm Depends on model
    Operation 8-inch touchscreen Basic keypad/display or touchscreen
    Measurement Modes Endpoint, two-point, kinetic Usually fewer modes
    Wavelength Mode Single and dual wavelength Depends on model
    Plate Shaking 3 speeds, 0–255 s Depends on model
    Cut-Off Formula User-defined May be limited
    Analysis Models Multiple linear and nonlinear models Usually fewer calculation options
    Program Storage 100 programs Depends on model
    Sample Result Storage 100,000 results Depends on model
    Food Safety Module Inhibition-rate measurement available Not necessarily available
     


    FAQ
    1.  What is the WD-2102B Microplate Reader?
    The WD-2102B is a non-medical automatic microplate reader designed for absorbance measurement, data analysis and microplate-based laboratory testing.
    2. What wavelength range does the WD-2102B support?
    It supports a wavelength range of 400–800 nm.
    3. What standard filters are included?
    The standard configuration includes 405 (or 412), 450, 492 and 630 nm filters. Other wavelengths can be selected, with up to 10 filters installable.
    4. What measurement modes are available?
    The instrument supports endpoint, two-point and kinetic measurement, together with single- and dual-wavelength modes.
    5. Does the WD-2102B have a plate shaking function?
    Yes. It provides three shaking speed levels, with shaking time adjustable from 0 to 255 seconds.
    6. Can users define their own Cut-Off calculation formula?
    Yes. The system provides an open Cut-Off judgment formula that allows users to enter the required formula.
    7. How much data can the software store?
    The system can store up to 100 programs and 100,000 sample results.
    8. Can the WD-2102B be used for food safety testing?
    Yes. An inhibition-rate measurement module is available for food safety-related applications.
    9. What is the absorbance reading range?
    The reading range is 0–4.000 Abs, with a resolution of 0.001 Abs.
     
  • FAQ
    1.  What is the WD-2102B Microplate Reader?
    The WD-2102B is a non-medical automatic microplate reader designed for absorbance measurement, data analysis and microplate-based laboratory testing.
    2. What wavelength range does the WD-2102B support?
    It supports a wavelength range of 400–800 nm.
    3. What standard filters are included?
    The standard configuration includes 405 (or 412), 450, 492 and 630 nm filters. Other wavelengths can be selected, with up to 10 filters installable.
    4. What measurement modes are available?
    The instrument supports endpoint, two-point and kinetic measurement, together with single- and dual-wavelength modes.
    5. Does the WD-2102B have a plate shaking function?
    Yes. It provides three shaking speed levels, with shaking time adjustable from 0 to 255 seconds.
    6. Can users define their own Cut-Off calculation formula?
    Yes. The system provides an open Cut-Off judgment formula that allows users to enter the required formula.
    7. How much data can the software store?
    The system can store up to 100 programs and 100,000 sample results.
    8. Can the WD-2102B be used for food safety testing?
    Yes. An inhibition-rate measurement module is available for food safety-related applications.
    9. What is the absorbance reading range?
    The reading range is 0–4.000 Abs, with a resolution of 0.001 Abs.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com